74 resultados para Augmented-Reality


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new image-guided microscope using augmented reality overlays has been developed. Unlike other systems, the novelty of our design consists in mounting a precise mini and low-cost tracker directly on the microscope to track the motion of the surgical tools and the patient. Correctly scaled cut-views of the pre-operative computed tomography (CT) stack can be displayed on the overlay, orthogonal to the optical view or even including the direction of a clinical tool. Moreover, the system can manage three-dimensional models for tumours or bone structures and allows interaction with them using virtual tools, showing trajectories and distances. The mean error of the overlay was 0.7 mm. Clinical accuracy has shown results of 1.1-1.8 mm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONCLUSION: Our self-developed planning and navigation system has proven its capacity for accurate surgery on the anterior and lateral skull base. With the incorporation of augmented reality, image-guided surgery will evolve into 'information-guided surgery'. OBJECTIVE: Microscopic or endoscopic skull base surgery is technically demanding and its outcome has a great impact on a patient's quality of life. The goal of the project was aimed at developing and evaluating enabling navigation surgery tools for simulation, planning, training, education, and performance. This clinically applied technological research was complemented by a series of patients (n=406) who were treated by anterior and lateral skull base procedures between 1997 and 2006. MATERIALS AND METHODS: Optical tracking technology was used for positional sensing of instruments. A newly designed dynamic reference base with specific registration techniques using fine needle pointer or ultrasound enables the surgeon to work with a target error of < 1 mm. An automatic registration assessment method, which provides the user with a color-coded fused representation of CT and MR images, indicates to the surgeon the location and extent of registration (in)accuracy. Integration of a small tracker camera mounted directly on the microscope permits an advantageous ergonomic way of working in the operating room. Additionally, guidance information (augmented reality) from multimodal datasets (CT, MRI, angiography) can be overlaid directly onto the surgical microscope view. The virtual simulator as a training tool in endonasal and otological skull base surgery provides an understanding of the anatomy as well as preoperative practice using real patient data. RESULTS: Using our navigation system, no major complications occurred in spite of the fact that the series included difficult skull base procedures. An improved quality in the surgical outcome was identified compared with our control group without navigation and compared with the literature. The surgical time consumption was reduced and more minimally invasive approaches were possible. According to the participants' questionnaires, the educational effect of the virtual simulator in our residency program received a high ranking.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: In this paper, we present a new method for the calibration of a microscope and its registration using an active optical tracker. METHODS: Practically, both operations are done simultaneously by moving an active optical marker within the field of view of the two devices. The IR LEDs composing the marker are first segmented from the microscope images. By knowing their corresponding three-dimensional (3D) position in the optical tracker reference system, it is possible to find the transformation matrix between the referential of the two devices. Registration and calibration parameters can be extracted directly from that transformation. In addition, since the zoom and focus can be modified by the surgeon during the operation, we propose a spline based method to update the camera model to the new setup. RESULTS: The proposed technique is currently being used in an augmented reality system for image-guided surgery in the fields of ear, nose and throat (ENT) and craniomaxillofacial surgeries. CONCLUSIONS: The results have proved to be accurate and the technique is a fast, dynamic and reliable way to calibrate and register the two devices in an OR environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dopamine has long held a prominent role in the interpretation of schizophrenia and other psychoses. Clinical studies on confabulation and disorientation, disorders marked by a confusion of reality in thinking, indicated that the ability to keep thinking in phase with reality depends on a process suppressing the interference of upcoming memories that do not refer to ongoing reality. A host of animal studies and a recent clinical study suggested that this suppression might correspond to the phasic inhibition of dopaminergic neurons in response to the absence of expected outcomes. In this study, we tested healthy subjects with a difficult version of a memory paradigm on which confabulating patients had failed. Subjects participated in three test sessions, in which they received in double-blind, randomized fashion L-dopa, risperidone, or placebo. We found that l-dopa, in comparison with risperidone, impaired performance in a highly specific way, which corresponded to the pattern of patients with reality confusion. Specifically, they had an increase of false positive responses, while overall memory performance and reaction times were unaffected. We conclude that dopaminergic transmission influences the ability to rapidly adapt thinking to ongoing reality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand transplantation has been indicated in selective patients after traumatic upper extremity amputation and only performed in a few centers around the world for the last decade. In comparison to solid organ transplantation, there is a challenge to overcome the host immunological barrier due to complex antigenicity of the different included tissues, the skin being the most susceptible to rejection. Patients require lifelong immunosuppression for non life-threatening conditions. Minimization of maintenance immunosuppression represents the key step for promoting wider applicability of hand transplantation. Current research is working towards the understanding mechanisms of composite tissue allograft (CTA) rejection. Worldwide, in 51 patients 72 hands (21 double hand transplants) and once both arms have been successfully transplanted since 1998.

Relevância:

20.00% 20.00%

Publicador: