87 resultados para Arnold, David


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Few data exist about clinical, radiologic findings, clinical outcome, and its predictors in patients with spontaneous vertebral artery dissection (sVAD). METHODS: Clinical characteristics, imaging findings, 3-month outcomes, and its predictors were investigated in consecutive patients with sVAD. RESULTS: One hundred sixty-nine patients with 195 sVAD were identified. Brain ischemia occurred in 131 patients (77%; ischemic stroke, n=114, 67%; transient ischemic attack, n=17, 10%). Three patients with ischemic stroke showed also signs of subarachnoid hemorrhage (SAH); 3 (2%) had SAH without ischemia. The 134 patients with brain ischemia or SAH had head and/or neck pain in 118 (88%) and pulsatile tinnitus in seven (5%) patients. The remaining 35 patients (21%) had isolated head and/or neck pain in 21 (12%) cases, asymptomatic sVAD in 13 (8%), and cervical radiculopathy in one case (1%). Location of sVAD was more often in the pars transversaria (V2; 35%) or atlas loop (V3; 34%) than in the prevertebral (V1; 20%) or intracranial (V4; 11%) segment (P=0.0001). Outcome was favorable (modified Rankin scale score 0 or 1) in 88 (82%) of 107 ischemic stroke patients with follow up. Two (2%) patients died. Low baseline National Institutes of Health Stroke Scale score (P<0.0001) and younger age (P=0.007) were independent predictors of favorable outcome. CONCLUSIONS: sVAD is predominantly located in the pars transversaria (V2) or the atlas loop (V3). Most patients show posterior circulation ischemia. Favorable outcome is observed in most ischemic strokes and independently predicted by low National Institutes of Health Stroke Scale score and younger age.