95 resultados para Aneurysms


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic aneurysms and aortic dissection represent a significant health risk due to the demographic developments and current life styles. The mortality of ruptured aortic aneurysms is up to 80 % and the prevalence of aneurysms varies depending on the localization (thoracic or abdominal). Most commonly affected is the infrarenal abdominal aorta; however, there is evidence that the prevalence is diminishing but in contrast the incidence of thoracic aortic aneurysms is increasing. Aortic dissection is often fatal and is the most common acute aortic disease but the incidence is presumed to be underestimated. The pathogenesis of aortic aneurysms is manifold and is based on an interplay between degenerative, proteolytic and inflammatory processes. An aortic dissection arises from a tear in the intima which results in a separation of the aortic wall layers with infiltration of bleeding and the danger of aortic rupture. Various genetic disorders of connective tissue promote degeneration of the aortic media, most notably Marfan syndrome. Risk factors for aortic aneurysms and aortic dissection are nicotine abuse, arterial hypertension, age and male gender. Aortic aneurysms initially have an uneventful course and as a consequence are mostly discovered incidentally. The clinical course and symptoms of aortic dissection are very much dependent on the section of the aorta affected and the manifestations are manifold. Acute aortic dissection is in 80 % of cases first manifested as sudden extremely severe pain. The diagnostics and subsequent course control can be achieved by a variety of imaging procedures but the modality of choice is computed tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-five years have passed since the first randomised controlled trial began its recruitment for screening for abdominal aortic aneurysm (AAA) in men aged 65 and above. Since this and other randomised trials, all launched in the late 80s and 90s of the last century, the epidemiologic profile of abdominal aortic aneurysm may have changed. The trials reported an AAA prevalence in the range of 4-7% for men aged 65 years or more. AAA-related mortality was significantly improved by screening, and after 13 years, the largest trial showed a benefit for all-cause mortality. Screening also was shown to be cost-effective. Today, there are studies showing a substantial decrease of AAA prevalence to sometimes less than 2% in men aged ≥ 65 years and there is evidence that the incidence of ruptured aneurysm and mortality from AAA is also declining. This decline preceded the implementation of screening programmes but may be due to a change in risk factor management. The prevalence of smoking has decreased and there has been improvement in the control of hypertension and a rising use of statins for cardiovascular risk prevention. Additionally, there is a shift of the burden to the older age group of ≥ 75 years. Such radical changes may influence screening policy and it is worth reflecting on the optimum age of screening - it might be better to screen at ages >65 years - or rescreening 5 to 10 years after the first screen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute dissection and rupture of aortic aneurysms comprise for 1-2% of all deaths in developed countries. Dilation of the aorta is caused by several different mechanisms including inherited disorders of connective tissue. Recent reports estimate that 20% of patients presenting with thoracic aortic disease do have an underlying genetic basis of disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rupture of intracranial aneurysms leads to subarachnoid hemorrhage, which is often associated with poor outcome. Preventive treatment of unruptured intracranial aneurysms is possible and recommended. However, the lack of candidate genes precludes identifying patients at risk by genetic analyses. We observed intracranial aneurysms in 2 patients with von Hippel-Lindau (VHL) disease and the known disease-causing mutation c.292T > C (p.Tyr98His) in the VHL tumor suppressor gene. This study investigates whether the VHL gene is a possible candidate gene for aneurysm formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In experimental aneurysm models, long-term patency without spontaneous thrombosis is the most important precondition for analyses of embolization devices. We recently reported the feasibility of creating complex venous pouch bifurcation aneurysms in the rabbit with low morbidity, low mortality, and high short-term aneurysm patency. In order to further evaluate our model, we examined the long-term patency rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.