263 resultados para ATRIAL FIBRILLATION
Resumo:
Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping.
Resumo:
Atrial fibrillation (AF) ablation has evolved to the treatment of choice for patients with drug-resistant and symptomatic AF. Pulmonary vein isolation at the ostial or antral level usually is sufficient for treatment of true paroxysmal AF. For persistent AF ablation, drivers and perpetuators outside of the pulmonary veins are responsible for AF maintenance and have to be targeted to achieve satisfying arrhythmia-free success rate. Both complex fractionated atrial electrogram (CFAE) ablation and linear ablation are added to pulmonary vein isolation for persistent AF ablation. Nevertheless, ablation failure and necessity of repeat ablations are still frequent, especially after persistent AF ablation. Pulmonary vein reconduction is the main reason for arrhythmia recurrence after paroxysmal and to a lesser extent after persistent AF ablation. Failure of persistent AF ablation mostly is a consequence of inadequate trigger ablation, substrate modification or incompletely ablated or reconducting linear lesions. In this review we will discuss these points responsible for AF recurrence after ablation and review current possibilities on how to overcome these limitations.
Resumo:
Coronary artery disease (CAD) and atrial fibrillation (AF) are major determinants of morbidity and mortality. A combined treatment with antiplatelet agents and vitamin K antagonists limits the risk of stent thrombosis and stroke while increasing the rate of bleeding. The objective of this study was to investigate the impact of atrial fibrillation (AF) on long-term clinical outcomes in patients with CAD undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Resumo:
During follow-up of between 1 and 3 years in the Randomized Evaluation of Long-term Anticoagulation Therapy (RE-LY) trial, 2 doses of dabigatran etexilate were shown to be effective and safe for the prevention of stroke or systemic embolism in patients with atrial fibrillation. There is a need for longer-term follow-up of patients on dabigatran and for further data comparing the 2 dabigatran doses.
Resumo:
BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.
Resumo:
BACKGROUND AND PURPOSE: For patients having suffered ischemic stroke, the current diagnostic strategies often fail to detect atrial fibrillation as a potential cause of embolic events. The aim of the study was to identify paroxysmal atrial fibrillation in stroke patients. We hypothesized that patients with frequent atrial premature beats (APBs) recorded in 24-hour ECG will show more often atrial fibrillation when followed by repeated long-term ECG recordings than patients without or infrequent APBs. METHODS: 127 patients with acute ischemic stroke and without known AF were enrolled in a prospective study to detect paroxysmal AF. Patients were stratified according to the number of APBs recorded in a 24-hour ECG (> or =70 APBs versus <70 APBs). Subsequently, they all underwent serial 7-day event-recorder monitoring at 0, 3, and 6 months. RESULTS: Serial extended ECG monitoring identified AF in 26% of patients with frequent APBs but only in 6.5% when APBs were infrequent (P=0.0021). A multivariate analysis showed that the presence of frequent APBs in the initial 24-hour ECG was the only independent predictor of paroxysmal AF during follow-up (odds ratio 6.6, 95% confidence intervals 1.6 to 28.2, P=0.01). CONCLUSIONS: In patients with acute ischemic stroke, frequent APBs (> or = 70/24 hours) are a marker for individuals who are at greater risk to develop or have paroxysmal AF. For such patients, we propose a diagnostic workup with repeated prolonged ECG monitoring to diagnose paroxysmal AF.
Resumo:
A shortening of the atrial refractory period has been considered as the main mechanism for the increased risk of atrial fibrillation in hyperthyroidism. However, other important factors may be involved.
Resumo:
OBJECTIVES: Recurrent embolic events after device closure of patent foramen ovale (PFO) have been related to incomplete closure. Another cause could be atrial fibrillation (AF). The aim of this study was to determine the incidence of AF in stroke patients after PFO closure. METHODS: Consecutive patients with device closure of a PFO after a stroke or transient ischemic attack and control patients with stroke underwent 7-day event loop recordings 3 and 6 months after PFO closure or stroke, respectively. RESULTS: Forty patients treated by PFO device closure 96 +/- 68 days after cryptogenic ischemic stroke and 70 control patients with ischemic stroke of other etiologies (known AF excluded) were compared. AF was identified in 6 patients (15%) of the treated group and in 12 control patients (17%, p = 0.77). In multivariate analysis, the presence of an occluder device was not an independent risk factor for AF. CONCLUSIONS: The incidence of AF is high after device closure of a PFO in stroke patients and similar to that in patients with stroke of non-PFO etiology and, hence, with no device. Further studies are required to determine the risk of thromboembolism and the optimal treatment in patients developing AF after device closure of a PFO.
Resumo:
The technique of transseptal puncture for catheter ablation of atrial fibrillation after percutaneous closure of a foramen ovale with the Amplatzer Occluder is demonstrated based on 2 representative cases.
Resumo:
BACKGROUND: Atrial fibrillation (AF) ablation is less frequently performed in women than in men. Although the prevalence of AF is slightly higher in men, this does not fully account for the lower number of AF ablations performed in women. This study sought to examine the effect of gender on referral for AF and subsequent AF management. METHODS: Consecutive patients referred to our tertiary arrhythmia outpatient clinic for AF management were retrospectively analyzed. RESULTS: Of 264 patients referred, only 27% were women. Women were older than men (63 +/- 9 vs 58 +/- 11 years, P = 0.002), more often had paroxysmal AF (78% vs 63% in men, P = 0.022), and women more frequently complained about palpitations (71% vs 49%, P = 0.002). In addition, they had more often experienced amiodarone side effects than men (56% vs 36%, P = 0.046). In this referred population, there was no difference in the proportion of women and men undergoing AF ablation immediately following the initial evaluation (21% vs 25%, P = ns), at any time during the follow-up (38% vs 44%, P = ns), and there was no difference in the proportion of patients undergoing atrioventricular node ablation in both sexes (6% of women vs 3% of men, P = ns). CONCLUSIONS: There is an important difference in the proportion of men and women referred for management of AF in a specialized outpatient arrhythmia clinic, with women being referred three times less often than men. However, there is no gender-related difference in the subsequent treatment decisions. These findings emphasize the importance of focusing on management of symptomatic AF in women.