27 resultados para 941
Resumo:
Attention deficit/hyperactivity disorder (ADHD) is a highly heritable neurodevelopmental disorder of childhood onset. Clinical and biological evidence points to shared common central nervous system (CNS) pathology of ADHD and restless legs syndrome (RLS). It was hypothesized that variants previously found to be associated with RLS in two large genome-wide association studies (GWA), will also be associated with ADHD. SNPs located in MEIS1 (rs2300478), BTBD9 (rs9296249, rs3923809, rs6923737), and MAP2K5 (rs12593813, rs4489954) as well as three SNPs tagging the identified haplotype in MEIS1 (rs6710341, rs12469063, rs4544423) were genotyped in a well characterized German sample of 224 families comprising one or more affected sibs (386 children) and both parents. We found no evidence for preferential transmission of the hypothesized variants to ADHD. Subsequent analyses elicited nominal significant association with haplotypes consisting of the three SNPs in BTBD9 (chi2 = 14.8, df = 7, nominal p = 0.039). According to exploratory post hoc analyses, the major contribution to this finding came from the A-A-A-haplotype with a haplotype-wise nominal p-value of 0.009. However, this result did not withstand correction for multiple testing. In view of our results, RLS risk alleles may have a lower effect on ADHD than on RLS or may not be involved in ADHD. The negative findings may additionally result from genetic heterogeneity of ADHD, i.e. risk alleles for RLS may only be relevant for certain subtypes of ADHD. Genes relevant to RLS remain interesting candidates for ADHD; particularly BTBD9 needs further study, as it has been related to iron storage, a potential pathophysiological link between RLS and certain subtypes of ADHD.
Resumo:
This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D (1) threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D (2) threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D(3) threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility.
Resumo:
Aims: We examined what type of STEMI patients are more likely to undergo multivessel PCI (MPCI) in a "real-world" setting and whether MPCI leads to worse or better outcomes compared with single-vessel PCI (SPCI) after stratifying patients by risk. Methods and results: Among STEMI patients enrolled in the Swiss AMIS Plus registry between 2005 and 2012 (n=12,000), 4,941 were identified with multivessel disease. We then stratified patients based on MPCI use and their risk. High-risk patients were identified a priori as those with: 1) left main (LM) involvement (lesions, n=263); 2) out-of-hospital cardiac arrest; or 3) Killip class III/IV. Logistic regression models examined for predictors of MPCI use and the association between MPCI and in-hospital mortality. Three thousand eight hundred and thirty-three (77.6%) patients underwent SPCI and 1,108 (22.4%) underwent MPCI. Rates of MPCI were greater among high-risk patients for each of the three categories: 8.6% vs. 5.9% for out-of-hospital cardiac arrest (p<0.01); 12.3% vs. 6.2% for Killip III/IV (p<0.001); and 14.5% vs. 2.7% for LM involvement (p<0.001). Overall, in-hospital mortality after MPCI was higher when compared with SPCI (7.3% vs. 4.4%; p<0.001). However, this result was not present when patients were stratified by risk: in-hospital mortality for MPCI vs. SPCI was 2.0% vs. 2.0% (p=1.00) in low-risk patients and 22.2% vs. 21.7% (p=1.00) in high-risk patients. Conclusions: High-risk patients are more likely to undergo MPCI. Furthermore, MPCI does not appear to be associated with higher mortality after stratifying patients based on their risk.
Resumo:
OBJECTIVE To determine the prevalence and spectrum of mutations associated with long QT syndrome (LQTS) and catecholaminergic polymorphic ventricular tachycardia (CPVT) in a seemingly unexplained drowning cohort. PATIENTS AND METHODS From September 1, 1998, through October 31, 2010, 35 unexplained drowning victims (23 male and 12 female; mean ± SD age, 17±12 years [range, 4-69 years]) were referred for a cardiac channel molecular autopsy. Of these, 28 (20 male and 8 female) drowned while swimming, and 7 (3 male and 4 female) were bathtub submersions. Polymerase chain reaction, denaturing high-performance liquid chromatography, and DNA sequencing were used for a comprehensive mutational analysis of the 3 major LQTS-susceptibility genes (KCNQ1, KCNH2, and SCN5A), and a targeted analysis of the CPVT1-associated, RYR2-encoded cardiac ryanodine receptor was conducted. RESULTS Of the 28 victims of swimming-related drowning, 8 (28.6%) were mutation positive, including 2 with KCNQ1 mutations (L273F, AAPdel71-73 plus V524G) and 6 with RYR2 mutations (R414C, I419F, R1013Q, V2321A, R2401H, and V2475F). None of the bathtub victims were mutation positive. Of the 28 victims who drowned while swimming, women were more likely to be mutation positive than men (5/8 [62.5%] vs 3/20 [15%]; P=.02). Although none of the mutation-positive, swimming-related drowning victims had a premortem diagnosis of LQTS or CPVT, a family history of cardiac arrest, family history of prior drowning, or QT prolongation was present in 50%. CONCLUSION Nearly 30% of the victims of swimming-related drowning hosted a cardiac channel mutation. Genetic testing should be considered in the postmortem evaluation of an unexplained drowning, especially if a positive personal or family history is elicited.
Resumo:
OBJECTIVES This study sought to determine the vascular anatomical eligibility for catheter-based renal artery denervation (RDN) in hypertensive patients. BACKGROUND Arterial hypertension is the leading cardiovascular risk factor for stroke and mortality globally. Despite substantial advances in drug-based treatment, many patients do not achieve target blood pressure levels. To improve the number of controlled patients, novel procedure- and device-based strategies have been developed. RDN is among the most promising novel techniques. However, there are few data on the vascular anatomical eligibility. METHODS We retrospectively analyzed 941 consecutive hypertensive patients undergoing coronary angiography and selective renal artery angiography between January 1, 2010, and May 31, 2012. Additional renal arteries were divided into 2 groups: hilar (accessory) and polar (aberrant) arteries. Anatomical eligibility for RDN was defined according to the current guidelines: absence of renal artery stenosis, renal artery diameter ≥4 mm, renal artery length ≥20 mm, and only 1 principal renal artery. RESULTS A total of 934 hypertensive patients were evaluable. The prevalence of renal artery stenosis was 10% (n = 90). Of the remaining 844 patients without renal artery stenosis, 727 (86%) had nonresistant hypertension and 117 (14%) had resistant hypertension; 62 (53%) of the resistant hypertensive and 381 (52%) of the nonresistant hypertensive patients were anatomically eligible for sympathetic RDN. CONCLUSIONS The vascular anatomical eligibility criteria of the current guidelines are a major limiting factor for the utilization of RDN as a therapeutic option. Development of new devices and/or techniques may significantly increase the number of candidates for these promising therapeutic options.
Resumo:
Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and results: Patients were divided into three groups: chronic TO (CTO; n=256), non-chronic TO (n=292), and no occlusion (n=2,941). Clinical and safety outcomes assessed through two years included target lesion failure (TLF: cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally occluded coronary arteries who receive revascularisation with an R-ZES have clinical outcomes comparable to those who receive a similar stent in non-occluded lesions.
Resumo:
Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.
Resumo:
Background. Between 2005 and 2012, annual sales of E-bikes in Switzerland increased from 1,792 to 52,941. This continuous and rapid transition from human-powered bicycles to an electric bicycle technology may indicate the increasing demand for low-cost transportation technology in combination with a healthy lifestyle. Material and Methods. In the present study, from April 2012 to September 2013, we retrospectively analysed E-bike accidents treated in the Emergency Department of our hospital by focusing on the following parameters: age, gender, time, period, and cause of the accident, as well as injury and outcome. Results. Patients were predominantly male. The mean age of injured E-cyclists was 47.5 years. The main causes of injury were self-accident. Most injuries were to the head/neck. The mean ISS was 8.48. The outcome showed that 9 patients were treated as outpatients, 9 were inpatients, and 5 patients were kept in the Intensive Care Unit (ICU). Only six patients underwent surgery (S). Discussion. This is the first attempt to evaluate E-bike injuries in Switzerland in an acute hospital setting. Since there is increasing popular preference for E-bikes as means of transportation and injuries to the head or neck are prevalent among E-cyclists, the hazard should not to be underestimated.
Resumo:
UNLABELLED The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. PATIENTS, MATERIAL AND METHODS 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. RESULTS Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. CONCLUSIONS SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.
Resumo:
OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.