34 resultados para 1539


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We sought to identify causative nongenetic and genetic risk factors for the bladder exstrophy-epispadias complex. MATERIALS AND METHODS: A total of 237 families with the bladder exstrophy-epispadias complex were invited to participate in the study, and information was obtained from 214 families, mainly from European countries. RESULTS: Two families showed familial occurrence. Male predominance was found among all subgroups comprising epispadias, classic bladder exstrophy and cloacal exstrophy, with male-to-female ratios of 1.4:1, 2.8:1 and 2.0:1, respectively (p = 0.001). No association with parental age, maternal reproductive history or periconceptional maternal exposure to alcohol, drugs, chemical noxae, radiation or infections was found. However, periconceptional maternal exposure to smoking was significantly more common in patients with cloacal exstrophy than in the combined group of patients with epispadias/classic bladder exstrophy (p = 0.009). Only 16.8% of mothers followed the current recommendations of periconceptional folic acid supplementation, and 17.6% had started supplementation before 10 weeks of gestation. Interestingly, in the latter group mothers of patients with cloacal exstrophy were more compliant with folic acid supplementation than were mothers of the combined group of patients with epispadias/classic bladder exstrophy (p = 0.037). Furthermore, mothers of children with cloacal exstrophy knew significantly more often prenatally that their child would have a congenital malformation than did mothers of children with epispadias/classic bladder exstrophy (p <0.0001). CONCLUSIONS: Our study corroborates the hypothesis that epispadias, classic bladder exstrophy and cloacal exstrophy are causally related, representing a spectrum of the same developmental defect, with a small risk of recurrence within families. Embryonic exposure to maternal smoking appears to enforce the severity, whereas periconceptional folic acid supplementation does not seem to alleviate it. There is a disproportional prenatal ultrasound detection rate between severe and mild phenotypes, possibly due to the neglect of imaging of full bladders with a focus on neural tube defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An important problem in unsupervised data clustering is how to determine the number of clusters. Here we investigate how this can be achieved in an automated way by using interrelation matrices of multivariate time series. Two nonparametric and purely data driven algorithms are expounded and compared. The first exploits the eigenvalue spectra of surrogate data, while the second employs the eigenvector components of the interrelation matrix. Compared to the first algorithm, the second approach is computationally faster and not limited to linear interrelation measures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper introduces a new rationale for the existence of “Directors’ and Officers’” (D&O) insurance. We use a model with volatile stock markets where shareholders design compensation schemes that incentivize managers to stimulate short-term increases in stock prices that do not maximize long run stock market value. We show that D&O insurance provides a convenient instrument for the initial shareholders of a company to take advantage of differences in beliefs between insiders and outsiders in capital markets. The empirical results support the idea that both the insurance coverage and the premium are higher in the presence of new shareholders and volatile markets. The results prove robust in various empirical model specifications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rank-based nonlinear predictability score was recently introduced as a test for determinism in point processes. We here adapt this measure to time series sampled from time-continuous flows. We use noisy Lorenz signals to compare this approach against a classical amplitude-based nonlinear prediction error. Both measures show an almost identical robustness against Gaussian white noise. In contrast, when the amplitude distribution of the noise has a narrower central peak and heavier tails than the normal distribution, the rank-based nonlinear predictability score outperforms the amplitude-based nonlinear prediction error. For this type of noise, the nonlinear predictability score has a higher sensitivity for deterministic structure in noisy signals. It also yields a higher statistical power in a surrogate test of the null hypothesis of linear stochastic correlated signals. We show the high relevance of this improved performance in an application to electroencephalographic (EEG) recordings from epilepsy patients. Here the nonlinear predictability score again appears of higher sensitivity to nonrandomness. Importantly, it yields an improved contrast between signals recorded from brain areas where the first ictal EEG signal changes were detected (focal EEG signals) versus signals recorded from brain areas that were not involved at seizure onset (nonfocal EEG signals).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. METHODS AND RESULTS We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. CONCLUSION Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gas-phase rotational motion of hexafluorobenzene has been measured in real time using femtosecond (fs) time-resolved rotational Raman coherence spectroscopy (RR-RCS) at T = 100 and 295 K. This four-wave mixing method allows to probe the rotation of non-polar gas-phase molecules with fs time resolution over times up to ∼5 ns. The ground state rotational constant of hexafluorobenzene is determined as B 0 = 1029.740(28) MHz (2σ uncertainty) from RR-RCS transients measured in a pulsed seeded supersonic jet, where essentially only the v = 0 state is populated. Using this B 0 value, RR-RCS measurements in a room temperature gas cell give the rotational constants B v of the five lowest-lying thermally populated vibrationally excited states ν7/8, ν9, ν11/12, ν13, and ν14/15. Their B v constants differ from B 0 by between −1.02 MHz and +2.23 MHz. Combining the B 0 with the results of all-electron coupled-cluster CCSD(T) calculations of Demaison et al. [Mol. Phys.111, 1539 (2013)] and of our own allow to determine the C-C and C-F semi-experimental equilibrium bond lengths r e(C-C) = 1.3866(3) Å and r e(C-F) = 1.3244(4) Å. These agree with the CCSD(T)/wCVQZ r e bond lengths calculated by Demaison et al. within ±0.0005 Å. We also calculate the semi-experimental thermally averaged bond lengths r g(C-C)=1.3907(3) Å and r g(C-F)=1.3250(4) Å. These are at least ten times more accurate than two sets of experimental gas-phase electron diffraction r g bond lengths measured in the 1960s.