516 resultados para Lorenz, Hendrik


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Peak levels of troponin T (TnT) reliably predict morbidity and mortality after cardiac surgery. However, the therapeutic window to manage CABG-related in-hospital complications may close before the peak is reached. We investigated whether early TnT levels correlate as well with complications after coronary artery bypass grafting (CABG) surgery. METHODS A 12 month consecutive series of patients undergoing elective isolated CABG procedures (mini-extra-corporeal circuit, Cardioplegic arrest) was analyzed. Logistic regression modeling was used to investigate whether TnT levels 6 to 8 hours after surgery were independently associated with in-hospital complications (either post-operative myocardial infarction, stroke, new-onset renal insufficiency, intensive care unit (ICU) readmission, prolonged ICU stay (>48 hours), prolonged need for vasopressors (>24 hours), resuscitation or death). RESULTS A total of 290 patients, including 36 patients with complications, was analyzed. Early TnT levels (odds ratio (OR): 6.8, 95% confidence interval (CI): 2.2-21.4, P=.001), logistic EuroSCORE (OR: 1.2, 95%CI: 1.0-1.3, P=.007) and the need for vasopressors during the first 6 postoperative hours (OR: 2.7, 95%CI: 1.0-7.1, P=.05) were independently associated with the risk of complications. With consideration of vasopressor use during the first 6 postoperative hours, the sum of specificity (0.958) and sensitivity (0.417) of TnT for subsequent complications was highest at a TnT cut-off value of 0.8 ng/mL. CONCLUSION Early TnT levels may be useful to guide ICU management of CABG patients. They predict clinically relevant complications within a potential therapeutic window, particularly in patients requiring vasopressors during the first postoperative hours, although with only moderate sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe several simulation algorithms that yield random probability distributions with given values of risk measures. In case of vanilla risk measures, the algorithms involve combining and transforming random cumulative distribution functions or random Lorenz curves obtained by simulating rather general random probability distributions on the unit interval. A new algorithm based on the simulation of a weighted barycentres array is suggested to generate random probability distributions with a given value of the spectral risk measure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to assess the occurrence, predictors, and mechanisms of optical coherence tomography (OCT)-detected coronary evaginations following drug-eluting stent (DES) implantation. BACKGROUND Angiographic ectasias and aneurysms in stented segments have been associated with a risk of late stent thrombosis. Using OCT, some stented segments show coronary evaginations reminiscent of ectasias. METHODS Evaginations were defined as outward bulges in the luminal contour between struts. They were considered major evaginations (MEs) when extending ≥3 mm along the vessel length, with a depth ≥10% of the stent diameter. A total of 228 patients who had sirolimus (SES)-, paclitaxel-, biolimus-, everolimus (EES)-, or zotarolimus (ZES)-eluting stents implanted in 254 lesions, were analysed after 1, 2, or 5 years; and serial assessment using OCT and intravascular ultrasound (IVUS) was performed post-intervention and after 1 year in 42 patients. RESULTS Major evaginations occurred frequently at all time points in SES (∼26%) and were rarely seen in EES (3%) and ZES (2%, P = 0.003). Sirolimus-eluting stent implantation was the strongest independent predictor of ME [adjusted OR (95% CI) 9.1 (1.1-77.4), P = 0.008]. Malapposed and uncovered struts were more common in lesions with vs. without ME (77 vs. 25%, P < 0.001 and 95 vs. 20%, P < 0.001, respectively) as was thrombus [49 vs. 14%, OR 7.3 (95% CI: 1.7-31.2), P = 0.007]. Post-intervention intra-stent dissection and protrusion of the vessel wall into the lumen were associated with an increased risk of evagination at follow-up [OR (95% CI): 2.9 (1.8-4.9), P < 0.001 and 3.3 (1.6-6.9), P = 0.001, respectively]. In paired IVUS analyses, lesions with ME showed a larger increase in the external elastic membrane area (20% area change) compared with lesions without ME (5% area change, P < 0.001). CONCLUSION Optical coherence tomography-detected MEs are a specific morphological footprint of early-generation SES and are nearly absent in newer-generation ZES and EES. Evaginations appear to be related to vessel injury at baseline; are associated with positive vessel remodelling; and correlate with uncoverage, malapposition, and thrombus at follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: Newer-generation everolimus-eluting stents (EES) have been shown to improve clinical outcomes compared with early-generation sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) in patients undergoing percutaneous coronary intervention (PCI). Whether this benefit is maintained among patients with saphenous vein graft (SVG) disease remains controversial. Methods and results: We assessed cumulative incidence rates (CIR) per 100 patient years after inverse probability of treatment weighting to compare clinical outcomes. The pre-specified primary endpoint was the composite of cardiac death, myocardial infarction (MI), and target vessel revascularisation (TVR). Out of 12,339 consecutively treated patients, 288 patients (5.7%) underwent PCI of at least one SVG lesion with EES (n=127), SES (n=103) or PES (n=58). Up to four years, CIR of the primary endpoint were 58.7 for EES, 45.2 for SES and 45.6 for PES with similar adjusted risks between groups (EES vs. SES; HR 0.94, 95% CI: 0.55-1.60, EES vs. PES; HR 1.07, 95% CI: 0.60-1.91). Adjusted risks showed no significant differences between stent types for cardiac death, MI and TVR. Conclusions: Among patients undergoing PCI for SVG lesions, newer-generation EES have similar safety and efficacy to early-generation SES and PES during long-term follow-up to four years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Optimal therapy for anterior cruciate ligament (ACL) rupture in the paediatric population still provokes controversy. Although conservative and operative treatments are both applied, operative therapy is slightly favored. Among available surgical techniques are physeal-sparing reconstruction and transphyseal graft fixation. The aim of this study was to present our mid-term results after transphyseal ACL reconstruction. METHODS Fifteen young patients (mean age=12.8±2.6, range=6.2-15.8years, Tanner stage=2-4) with open physis and traumatic anterior cruciate rupture who had undergone transphyseal ACL reconstruction with unilateral quadriceps tendon graft were prospectively analyzed. All children were submitted to radiological evaluation to determine the presence of clearly open growth plates in both the distal femur and proximal tibia. Postoperatively, all patients were treated according to a standardized rehabilitation protocol and evaluated by radiographic analysis and the Lysholm-Gillquist and IKDC 2000 scores. Their health-related quality of life was measured using the SF-12 PCS (physical component summary) and MCS (mental component summary) questionnaires. RESULTS Mean postoperative follow-up was 4.1years. Mean Lysholm-Gillquist score was 94.0. Thirteen of the 15 knees were considered nearly normal on the IKDC 2000 score. The mean SF-12 questionnaire score was 54.0±4.8 for SF-12 PCS and 59.1±3.7 for SF-12 MCS. No reruptures were observed. Radiological analysis detected one knee with valgus deformity. All patients had a normal gait pattern without restrictions. CONCLUSION Transphyseal reconstruction of the anterior cruciate ligament shows satisfactory mid-term results in the immature patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow. Methods and results: OCT-detected evaginations are defined as outward bulges in the luminal vessel contour between struts, with the depth of the bulge exceeding the actual strut thickness. Evaginations can be characterised cross ectionally by depth and along the stented segment by total length. Assuming an ellipsoid shape, we modelled 3-D evaginations with different sizes by varying the depth from 0.2-1.0 mm, and the length from 1-9 mm. For the flow simulation we used average flow velocity data from non-diseased coronary arteries. The change in flow with varying evagination sizes was assessed using a particle tracing test where the particle transit time within the segment with evagination was compared with that of a control vessel. The presence of the evagination caused a delayed particle transit time which increased with the evagination size. The change in flow consisted locally of recirculation within the evagination, as well as flow deceleration due to a larger lumen - seen as a deflection of flow towards the evagination. Conclusions: CFD simulation of 3-D evaginations and blood flow suggests that evaginations affect flow locally, with a flow disturbance that increases with increasing evagination size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Reinfection after treatment for Chlamydia trachomatis or Neisseria gonorrhoeae reduces the effect of control interventions. We explored the impact of delays in treatment of current partners on the expected probability of reinfection of index cases using a mathematical model. METHODS We used previously reported parameter distributions to calculate the probability that index cases would be reinfected by their untreated partners. We then assumed different delays between index case and partner treatment to calculate the probabilities of reinfection. RESULTS In the absence of partner treatment, the medians of the expected reinfection probabilities are 19.4% (IQR 9.2-31.6%) for C trachomatis and 12.5% (IQR 5.6-22.2%) for N gonorrhoeae. If all current partners receive treatment 3 days after the index case, the expected reinfection probabilities are 4.2% (IQR 2.1-6.9%) for C trachomatis and 5.5% (IQR 2.6-9.5%) for N gonorrhoeae. CONCLUSIONS Quicker partner referral and treatment can substantially reduce reinfection rates for C trachomatis and N gonorrhoeae by untreated partners. The formula we used to calculate reinfection rates can be used to inform the design of randomised controlled trials of novel partner notification technologies like accelerated partner therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Periprosthetic infections remain a devastating problem in the field of joint arthroplasty. In the following study, the results of a two-stage treatment protocol for chronic periprosthetic infections using an intraoperatively molded cement prosthesis-like spacer (CPLS) are presented. METHODS Seventy-five patients with chronically infected knee prosthesis received a two-stage revision procedure with the newly developed CPLS between June 2006 and June 2011. Based on the microorganism involved, patients were grouped into either easy to treat (ETT) or difficult to treat (DTT) and treated accordingly. Range of motion (ROM) and the knee society score (KSS) were utilized for functional assessment. RESULTS Mean duration of the CPLS implant in the DTT group was 3.6 months (range 3-5 months) and in the ETT group 1.3 months (range 0.7-2.5 months). Reinfection rates of the final prosthesis were 9.6% in the ETT and 8.3% in the DTT group with no significant difference between both groups regarding ROM or KSS (P = 0.87, 0.64, resp.). CONCLUSION The results show that ETT patients do not necessitate the same treatment protocol as DTT patients to achieve the same goal, emphasizing the need to differentiate between therapeutic regimes. We also highlight the feasibility of CLPS in two-stage protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to evaluate if osseous correction of the femoral neck achieved arthroscopically is comparable to that achieved by surgical dislocation. METHODS We retrospectively analyzed all patients who were treated with hip arthroscopy or surgical dislocation for cam or mixed type femoroacetabular impingement (FAI) in our institution between 2006 and 2009. Inclusion criteria were complete clinical and radiologic documentation with standardized radiographs. Group 1 consisted of 66 patients (49 female patients, mean age 33.8 years) treated with hip arthroscopy. Group 2 consisted of 135 patients (91 male patients, mean age 31.2 years) treated with surgical hip dislocation. We compared the preoperative and postoperative alpha and gamma angles, as well as the triangular index. Mean follow-up was 16.7 months (range, 2 to 79 months). RESULTS In group 1, the mean alpha angle improved from 60.7° preoperatively to 47.8° postoperatively (P < .001) and the mean gamma angle improved from 47.3° to 44.5° (P < .001). Over time, the preoperative mean alpha angle increased from 56.3° in 2006 to 67.5° in 2009, whereas the postoperative mean alpha angle decreased from 51.2° in 2006 to 47.5° in 2009. In group 2, the mean alpha angle improved from 75.3° preoperatively to 44.8° postoperatively (P < .001), and the mean gamma angle improved from 65.1° to 52.2° (P < .001). Arthroscopic revision of intra-articular adhesions was performed in 4 patients (6.1%) in group 1 and 16 patients (12%) in group 2. Three patients (2.2%) in group 2 underwent revision for nonunion of the greater trochanter. CONCLUSIONS Osseous correction of cam-type FAI with hip arthroscopy is comparable to the correction achieved by surgical hip dislocation. There is a significant learning curve for hip arthroscopy, with postoperative osseous correction showing improved results with increasing surgical experience. LEVEL OF EVIDENCE Level III, retrospective comparative study.