255 resultados para Stents eluidores de sirolimus
Resumo:
BACKGROUND Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. METHODS Patients recruited in the Comfortable AMI-IBIS 4 study implanted with bare metal stents (BMS) or biolimus eluting stents (BES) that had biplane coronary angiography at 13month follow-up were included in the analysis. The intravascular ultrasound virtual-histology (IVUS-VH) and the angiographic data were used to reconstruct the luminal surface, and the stent in the stented segments. Blood flow simulation was performed in the stent surface, which was assumed to represent the luminal surface at baseline, to assess the association between ESS and neointima thickness. The predominant ESS was estimated in 3-mm segments and was correlated with the amount of neointima, neointimal tissue composition, and with the changes in the underlying plaque burden and composition. RESULTS Forty three patients (18 implanted with BMS and 25 with BES) were studied. In both stent groups negative correlations were noted between ESS and neointima thickness in BMS (P<0.001) and BES (P=0.002). In BMS there was a negative correlation between predominant ESS and the percentage of the neointimal necrotic core component (P=0.015). In BES group, the limited neointima formation did not allow evaluation of the effect of ESS on its tissue characteristics. ESS did not affect vessel wall remodeling and the plaque burden and composition behind BMS (P>0.10) and BES (P>0.45). CONCLUSIONS ESS determines neointimal formation in both BMS and BES and affects the composition of the neointima in BMS. Conversely, ESS does not impact the plaque behind struts irrespective of stent type throughout 13months of follow-up.
Resumo:
BACKGROUND The risk factors and clinical sequelae of gastrointestinal bleeding (GIB) in the current era of drug-eluting stents, prolonged dual antiplatelet therapy, and potent P2Y12 inhibitors are not well established. We determined the frequency, predictors, and clinical impact of GIB after percutaneous coronary interventions (PCIs) in a contemporary cohort of consecutive patients treated with unrestricted use of drug-eluting stents. METHODS AND RESULTS Between 2009 and 2012, all consecutive patients undergoing PCI were prospectively included in the Bern PCI Registry. Bleeding Academic Research Consortium (BARC) GIB and cardiovascular outcomes were recorded within 1 year of follow-up. Among 6212 patients, 84.1% received new-generation drug-eluting stents and 19.5% received prasugrel. At 1 year, GIB had occurred in 65 patients (1.04%); 70.8% of all events and 84.4% of BARC ≥3B events were recorded >30 days after PCI. The majority of events (64.4%) were related to upper GIB with a more delayed time course compared with lower GIB. Increasing age, previous GIB, history of malignancy, smoking, and triple antithrombotic therapy (ie, oral anticoagulation plus dual antiplatelet therapy) were independent predictors of GIB in multivariable analysis. GIB was associated with increased all-cause mortality (adjusted hazard ratio, 3.40; 95% confidence interval, 1.67-6.92; P=0.001) and the composite of death, myocardial infarction, or stroke (adjusted hazard ratio, 3.75; 95% confidence interval, 1.99-7.07; P<0.001) and was an independent predictor of all-cause mortality during 1 year. CONCLUSIONS Among unselected patients undergoing PCI, GIB has a profound effect on prognosis. Triple antithrombotic therapy emerged as the single drug-related predictor of GIB in addition to patient-related risk factors within 1 year of PCI. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.
Resumo:
BACKGROUND Definitive fate of the coronary endothelium after implantation of a drug-eluting stent remains unclear, but evidence has accumulated that treatment with rapamycin-eluting stents impairs endothelial function in human coronary arteries. The aim of our study was to demonstrate this phenomenon on functional, morphological and biochemical level in human internal thoracic arteries (ITA) serving as coronary artery model. METHODS After exposure to rapamycin for 20 h, functional activity of ITA rings was investigated using the organ bath technique. Morphological analysis was performed by scanning electron microscopy and evaluated by two independent observers in blinded fashion. For measurement of endothelial nitric oxide synthase (eNOS) release, mammalian target of rapamycin (mTOR) and protein kinase B (PKB) (Akt) activation, Western blotting on human mammary epithelial cells-1 and on ITA homogenates was performed. RESULTS Comparison of the acetylcholine-induced relaxation revealed a significant concentration-dependent decrease to 66 ± 7 % and 36 ± 7 % (mean ± SEM) after 20-h incubation with 1 and 10 μM rapamycin. Electron microscopic evaluation of the endothelial layer showed no differences between controls and samples exposed to 10 μM rapamycin. Western blots after 20-h incubation with rapamycin (10 nM-1 μM) revealed a significant and concentration-dependent reduction of p (Ser 1177)-eNOS (down to 38 ± 8 %) in human mammary epithelial cells (Hmec)-1. Furthermore, 1 μM rapamycin significantly reduced activation of p (Ser2481)-mTOR (58 ± 11 %), p (Ser2481)-mTOR (23 ± 4 %) and p (Ser473)-Akt (38 ± 6 %) in ITA homogenates leaving Akt protein levels unchanged. CONCLUSIONS The present data suggests that 20-h exposure of ITA rings to rapamycin reduces endothelium-mediated relaxation through down-regulation of Akt-phosphorylation via the mTOR signalling axis within the ITA tissue without injuring the endothelial cell layer.
Resumo:
Nitinol stent oversizing is frequently performed in peripheral arteries to ensure a desirable lumen gain. However, the clinical effect of mis-sizing remains controversial. The goal of this study was to provide a better understanding of the structural and hemodynamic effects of Nitinol stent oversizing. Five patient-specific numerical models of non-calcified popliteal arteries were developed to simulate the deployment of Nitinol stents with oversizing ratios ranging from 1.1 to 1.8. In addition to arterial biomechanics, computational fluid dynamics methods were adopted to simulate the physiological blood flow inside the stented arteries. Results showed that stent oversizing led to a limited increase in the acute lumen gain, albeit at the cost of a significant increase in arterial wall stresses. Furthermore, localized areas affected by low Wall Shear Stress increased with higher oversizing ratios. Stents were also negatively impacted by the procedure as their fatigue safety factors gradually decreased with oversizing. These adverse effects to both the artery walls and stents may create circumstances for restenosis. Although the ideal oversizing ratio is stent-specific, this study showed that Nitinol stent oversizing has a very small impact on the immediate lumen gain, which contradicts the clinical motivations of the procedure.
Resumo:
AIMS The GLOBAL LEADERS trial is a superiority study in patients undergoing percutaneous coronary intervention, with a uniform use of Biolimus A9-eluting stents (BES) and bivalirudin. GLOBAL LEADERS was designed to assess whether a 24-month antithrombotic regimen with ticagrelor and one month of acetylsalicylic acid (ASA), compared to conventional dual antiplatelet therapy (DAPT), improves outcomes. METHODS AND RESULTS Patients (n >16,000) are randomised (1:1 ratio) to ticagrelor 90 mg twice daily for 24 months plus ASA ≤100 mg for one month versus DAPT with either ticagrelor (acute coronary syndrome) or clopidogrel (stable coronary artery disease) for 12 months plus ASA ≤100 mg for 24 months. The primary outcome is a composite of all-cause mortality or non-fatal, new Q-wave myocardial infarction at 24 months. The key safety endpoint is investigator-reported class 3 or 5 bleeding according to the Bleeding Academic Research Consortium (BARC) definitions. Sensitivity analysis will be carried out to explore potential differences in outcome across geographic regions and according to specific angiographic and clinical risk estimates. CONCLUSIONS The GLOBAL LEADERS trial aims to assess the role of ticagrelor as a single antiplatelet agent after a short course of DAPT for the long-term prevention of cardiac adverse events, across a wide spectrum of patients, following BES implantation.
Resumo:
OBJECTIVES This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. BACKGROUND Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. METHODS Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. RESULTS Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). CONCLUSIONS DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938).
Resumo:
Stable coronary artery disease is the most common clinical manifestation of ischaemic heart disease and a leading cause of mortality worldwide. Myocardial revascularisation is a mainstay in the treatment of symptomatic patients or those with ischaemia-producing coronary lesions, and reduces ischaemia to a greater extent than medical treatment. Documentation of ischaemia and plaque burden is fundamental in the risk stratification of patients with stable coronary artery disease, and several invasive and non-invasive techniques are available (eg, fractional flow reserve or intravascular ultrasound) or being validated (eg, instantaneous wave-free ratio and optical coherence tomography). The use of new-generation drug-eluting stents and arterial conduits greatly improve clinical outcome in patients undergoing percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). PCI is feasible, safe, and effective in many patients with stable coronary artery disease who remain symptomatic despite medical treatment. In patients with multivessel and left main coronary artery disease, the decision between PCI or CABG is guided by the local Heart Team (team of different cardiovascular specialists, including non-invasive and invasive cardiologists, and cardiac surgeons), who carefully judge the possible benefits and risks inherent to PCI and CABG. In specific subsets, such as patients with diabetes and advanced, multivessel coronary artery disease, CABG remains the standard of care in view of improved protection against recurrent ischaemic adverse events.
Resumo:
The joint European Society of Cardiology and European Association of Cardio-Thoracic Surgery (ESC/EACTS) guidelines on myocardial revascularization collect and summarize the evidence regarding decision-making, diagnostics, and therapeutics in various clinical scenarios of coronary artery disease, including elective, urgent, and emergency settings. The 2014 document updates and extends the effort started in 2010, year of the first edition of these guidelines. Importantly, this latest edition provides a systematic review of all randomized clinical trials performed since 1980, comparing different strategies of myocardial revascularization, including coronary artery bypass graft (CABG), balloon angioplasty, percutaneous coronary intervention (PCI) with bare-metal stents (BMS) and first- and second-generation drug-eluting stents (DES). This review aims to highlight the most relevant novelties introduced by the 2014 edition of the ESC/EACTS myocardial revascularization guidelines as compared with the previous edition and to describe similarities and differences with the American societies' guidelines.
Resumo:
The choice and duration of antiplatelet therapy for secondary prevention of coronary artery disease (CAD) is determined by the clinical context and treatment strategy. Oral antiplatelet agents for secondary prevention include the cyclo-oxygenase-1 inhibitor aspirin, and the ADP dependent P2Y12 inhibitors clopidogrel, prasugrel and ticagrelor. Aspirin constitutes the cornerstone in secondary prevention of CAD and is complemented by clopidogrel in patients with stable CAD undergoing percutaneous coronary intervention. Among patients with acute coronary syndrome, prasugrel and ticagrelor improve net clinical outcome by reducing ischaemic adverse events at the expense of an increased risk of bleeding as compared with clopidogrel. Prasugrel appears particularly effective among patients with ST elevation myocardial infarction to reduce the risk of stent thrombosis compared with clopidogrel, and offered a greater net clinical benefit among patients with diabetes compared with patients without diabetes. Ticagrelor is associated with reduced mortality without increasing the rate of coronary artery bypass graft (CABG)-related bleeding as compared with clopidogrel. Dual antiplatelet therapy should be continued for a minimum of 1 year among patients with acute coronary syndrome irrespective of stent type; among patients with stable CAD treated with new generation drug-eluting stents, available data suggest no benefit to prolong antiplatelet treatment beyond 6 months.
Resumo:
BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.
Resumo:
BACKGROUND The benefits and risks of prolonged dual antiplatelet therapy may be different for patients with acute myocardial infarction (MI) compared with more stable presentations. OBJECTIVES This study sought to assess the benefits and risks of 30 versus 12 months of dual antiplatelet therapy among patients undergoing coronary stent implantation with and without MI. METHODS The Dual Antiplatelet Therapy Study, a randomized double-blind, placebo-controlled trial, compared 30 versus 12 months of dual antiplatelet therapy after coronary stenting. The effect of continued thienopyridine on ischemic and bleeding events among patients initially presenting with versus without MI was assessed. The coprimary endpoints were definite or probable stent thrombosis and major adverse cardiovascular and cerebrovascular events (MACCE). The primary safety endpoint was GUSTO (Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Arteries) moderate or severe bleeding. RESULTS Of 11,648 randomized patients (9,961 treated with drug-eluting stents, 1,687 with bare-metal stents), 30.7% presented with MI. Between 12 and 30 months, continued thienopyridine reduced stent thrombosis compared with placebo in patients with and without MI at presentation (MI group, 0.5% vs. 1.9%, p < 0.001; no MI group, 0.4% vs. 1.1%, p < 0.001; interaction p = 0.69). The reduction in MACCE for continued thienopyridine was greater for patients with MI (3.9% vs. 6.8%; p < 0.001) compared with those with no MI (4.4% vs. 5.3%; p = 0.08; interaction p = 0.03). In both groups, continued thienopyridine reduced MI (2.2% vs. 5.2%, p < 0.001 for MI; 2.1% vs. 3.5%, p < 0.001 for no MI; interaction p = 0.15) but increased bleeding (1.9% vs. 0.8%, p = 0.005 for MI; 2.6% vs. 1.7%, p = 0.007 for no MI; interaction p = 0.21). CONCLUSIONS Compared with 12 months of therapy, 30 months of dual antiplatelet therapy reduced the risk of stent thrombosis and MI in patients with and without MI, and increased bleeding. (The Dual Antiplatelet Therapy Study [The DAPT Study]; NCT00977938).
Resumo:
BACKGROUND An increased body mass index (BMI) is associated with a high risk of cardiovascular disease and reduction in life expectancy. However, several studies reported improved clinical outcomes in obese patients treated for cardiovascular diseases. The aim of the present study is to investigate the impact of BMI on long-term clinical outcomes after implantation of zotarolimus eluting stents. METHODS Individual patient data were pooled from the RESOLUTE Clinical Program comprising five trials worldwide. The study population was sorted according to BMI tertiles and clinical outcomes were evaluated at 2-year follow-up. RESULTS Data from a total of 5,127 patients receiving the R-ZES were included in the present study. BMI tertiles were as follow: I tertile (≤ 25.95 kg/m(2) -Low or normal weight) 1,727 patients; II tertile (>25.95 ≤ 29.74 kg/m(2) -overweight) 1,695 patients, and III tertile (>29.74 kg/m(2) -obese) 1,705 patients. At 2-years follow-up no difference was found for patients with high BMI (III tertile) compared with patients with normal or low BMI (I tertile) in terms of target lesion failure (I-III tertile, HR [95% CI] = 0.89 [0.69, 1.14], P = 0.341; major adverse cardiac events (I-III tertile, HR [95% CI] = 0.90 [0.72, 1.14], P = 0.389; cardiac death (I-III tertile, HR [95% CI] = 1.20 [0.73, 1.99], P = 0.476); myocardial infarction (I-III tertile, HR [95% CI] = 0.86 [0.55, 1.35], P = 0.509; clinically-driven target lesion revascularization (I-III tertile, HR [95% CI] = 0.75 [0.53, 1.08], P = 0.123; definite or probable stent thrombosis (I-III tertile, HR [95% CI] = 0.98 [0.49, 1.99], P = 0.964. CONCLUSIONS In the present study, the patients' body mass index was found to have no impact on long-term clinical outcomes after coronary artery interventions.
Resumo:
This paper reviews the methods, benefits and challenges associated with the adoption and translation of computational fluid dynamics (CFD) modelling within cardiovascular medicine. CFD, a specialist area of mathematics and a branch of fluid mechanics, is used routinely in a diverse range of safety-critical engineering systems, which increasingly is being applied to the cardiovascular system. By facilitating rapid, economical, low-risk prototyping, CFD modelling has already revolutionised research and development of devices such as stents, valve prostheses, and ventricular assist devices. Combined with cardiovascular imaging, CFD simulation enables detailed characterisation of complex physiological pressure and flow fields and the computation of metrics which cannot be directly measured, for example, wall shear stress. CFD models are now being translated into clinical tools for physicians to use across the spectrum of coronary, valvular, congenital, myocardial and peripheral vascular diseases. CFD modelling is apposite for minimally-invasive patient assessment. Patient-specific (incorporating data unique to the individual) and multi-scale (combining models of different length- and time-scales) modelling enables individualised risk prediction and virtual treatment planning. This represents a significant departure from traditional dependence upon registry-based, population-averaged data. Model integration is progressively moving towards 'digital patient' or 'virtual physiological human' representations. When combined with population-scale numerical models, these models have the potential to reduce the cost, time and risk associated with clinical trials. The adoption of CFD modelling signals a new era in cardiovascular medicine. While potentially highly beneficial, a number of academic and commercial groups are addressing the associated methodological, regulatory, education- and service-related challenges.
Resumo:
OBJECTIVES This study sought to evaluate: 1) the effect of impaired renal function on long-term clinical outcomes in women undergoing percutaneous coronary intervention (PCI) with drug-eluting stent (DES); and 2) the safety and efficacy of new-generation compared with early-generation DES in women with chronic kidney disease (CKD). BACKGROUND The prevalence and effect of CKD in women undergoing PCI with DES is unclear. METHODS We pooled patient-level data for women enrolled in 26 randomized trials. The study population was categorized by creatinine clearance (CrCl) <45 ml/min, 45 to 59 ml/min, and ≥60 ml/min. The primary endpoint was the 3-year rate of major adverse cardiovascular events (MACE). Participants for whom baseline creatinine was missing were excluded from the analysis. RESULTS Of 4,217 women included in the pooled cohort treated with DES and for whom serum creatinine was available, 603 (14%) had a CrCl <45 ml/min, 811 (19%) had a CrCl 45 to 59 ml/min, and 2,803 (66%) had a CrCl ≥60 ml/min. A significant stepwise gradient in risk for MACE was observed with worsening renal function (26.6% vs. 15.8% vs. 12.9%; p < 0.01). Following multivariable adjustment, CrCl <45 ml/min was independently associated with a higher risk of MACE (adjusted hazard ratio: 1.56; 95% confidence interval: 1.23 to 1.98) and all-cause mortality (adjusted hazard ratio: 2.67; 95% confidence interval: 1.85 to 3.85). Compared with older-generation DES, the use of newer-generation DES was associated with a reduction in the risk of cardiac death, myocardial infarction, or stent thrombosis in women with CKD. The effect of new-generation DES on outcomes was uniform, between women with or without CKD, without evidence of interaction. CONCLUSIONS Among women undergoing PCI with DES, CKD is a common comorbidity associated with a strong and independent risk for MACE that is durable over 3 years. The benefits of newer-generation DES are uniform in women with or without CKD.
Resumo:
BACKGROUND The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. METHODS AND RESULTS Between August 2010 and December 2014, 64 patients were investigated at the time point of VLST as part of an international optical coherence tomography registry. Optical coherence tomography pullbacks were performed after restoration of flow and analyzed at 0.4 mm. A total of 38 early- and 20 newer-generation drug-eluting stents were suitable for analysis. VLST occurred at a median of 4.7 years (interquartile range, 3.1-7.5 years). An underlying putative cause by optical coherence tomography was identified in 98% of cases. The most frequent findings were strut malapposition (34.5%), neoatherosclerosis (27.6%), uncovered struts (12.1%), and stent underexpansion (6.9%). Uncovered and malapposed struts were more frequent in thrombosed compared with nonthrombosed regions (ratio of percentages, 8.26; 95% confidence interval, 6.82-10.04; P<0.001 and 13.03; 95% confidence interval, 10.13-16.93; P<0.001, respectively). The maximal length of malapposed or uncovered struts (3.40 mm; 95% confidence interval, 2.55-4.25; versus 1.29 mm; 95% confidence interval, 0.81-1.77; P<0.001), but not the maximal or average axial malapposition distance, was greater in thrombosed compared with nonthrombosed segments. The associations of both uncovered and malapposed struts with thrombus were consistent among early- and newer-generation drug-eluting stents. CONCLUSIONS The leading associated findings in VLST patients in descending order were malapposition, neoatherosclerosis, uncovered struts, and stent underexpansion without differences between patients treated with early- and new-generation drug-eluting stents. The longitudinal extension of malapposed and uncovered stent was the most important correlate of thrombus formation in VLST.