258 resultados para MULTISLICE CT
Resumo:
Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.
Resumo:
This paper addresses the issue of fully automatic segmentation of a hip CT image with the goal to preserve the joint structure for clinical applications in hip disease diagnosis and treatment. For this purpose, we propose a Multi-Atlas Segmentation Constrained Graph (MASCG) method. The MASCG method uses multi-atlas based mesh fusion results to initialize a bone sheetness based multi-label graph cut for an accurate hip CT segmentation which has the inherent advantage of automatic separation of the pelvic region from the bilateral proximal femoral regions. We then introduce a graph cut constrained graph search algorithm to further improve the segmentation accuracy around the bilateral hip joint regions. Taking manual segmentation as the ground truth, we evaluated the present approach on 30 hip CT images (60 hips) with a 15-fold cross validation. When the present approach was compared to manual segmentation, an average surface distance error of 0.30 mm, 0.29 mm, and 0.30 mm was found for the pelvis, the left proximal femur, and the right proximal femur, respectively. A further look at the bilateral hip joint regions demonstrated an average surface distance error of 0.16 mm, 0.21 mm and 0.20 mm for the acetabulum, the left femoral head, and the right femoral head, respectively.
Resumo:
BACKGROUND AND PURPOSE The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
BACKGROUND Infiltration procedures are a common treatment of lumbar radiculopathy. There is a wide variety of infiltration techniques without an established gold standard. Therefore, we compared the effectiveness of CT-guided transforaminal infiltrations versus anatomical landmark-guided transforaminal infiltrations at the lower lumbar spine in case of acute sciatica at L3-L5. METHODS A retrospective chart review was conducted of 107 outpatients treated between 2009 and 2011. All patients were diagnosed with lumbar radiculopathic pain secondary to disc herniation in L3-L5. A total of 52 patients received CT-guided transforaminal infiltrations; 55 patients received non-imaging-guided nerve root infiltrations. The therapeutic success was evaluated regarding number of physician contacts, duration of treatment, type of analgesics used and loss of work days. Defined endpoint was surgery at the lower lumbar spine. RESULTS In the CT group, patients needed significantly less oral analgesics (p < 0.001). Overall treatment duration and physician contacts were significantly lower in the CT group (p < 0.001 and 0.002) either. In the CT group, patients lost significant fewer work days due to incapacity (p < 0.001). Surgery had to be performed in 18.2 % of the non-imaging group patients (CT group: 1.9 %; p = 0.008). CONCLUSION This study shows that CT-guided periradicular infiltration in lumbosciatica caused by intervertebral disc herniation is significantly superior to non-imaging, anatomical landmark-guided infiltration, regarding the parameters investigated. The high number of treatment failures in the non-imaging group underlines the inferiority of this treatment concept.
Resumo:
UNLABELLED The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. PATIENTS, MATERIAL AND METHODS 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. RESULTS Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. CONCLUSIONS SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.
Resumo:
OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.
Resumo:
PURPOSE To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. MATERIALS AND METHODS Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. RESULTS Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. CONCLUSION AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.
Resumo:
PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring.
Resumo:
The goal of this study was to assess whether epicardial and paracardial adipose tissue volumes, as determined by computed tomography (CT), correlate with coronary artery stenosis as determined by autopsy. The postmortem CT data and autopsy findings of 116 adult human decedents were retrospectively compared. Subjects were classified into three groups according to their degree of coronary artery stenosis: ≥50, <50%, and no stenosis. Epicardial and paracardial adipose tissue volumes were calculated based on manual segmentation after threshold based masking. In addition, epicardial adipose tissue thickness was measured using a caliper. All three parameters (thickness of epicardial fat and volumes of both epicardial and paracardial fat) were compared among the three groups and correlated with the degree of coronary artery stenosis. The group with no coronary artery stenosis showed the lowest mean values of epicardial adipose tissue volume, while the coronary artery stenosis ≥50 % group showed the highest volume. All measured variables (thickness of epicardial fat and volumes of both epicardial and paracardial fat) correlated significantly with the grade of coronary artery stenosis, even after controlling for BMI, however, epicardial adipose tissue volume exhibited the strongest correlation. This study reveals that there is an association between the degree of coronary artery stenosis and the amount of epicardial fat tissue: The larger the volume of epicardial fat, the higher the degree of coronary artery stenosis.
Resumo:
PURPOSE The aim of this study was to investigate if (1) the volume of subdural hematomas (SDH), midline shift, and CT density of subdural hematomas are altered by postmortem changes and (2) if these changes are dependent on the postmortem interval (PMI). MATERIALS AND METHODS Ante mortem computed tomography (AMCT) of the head was compared to corresponding postmortem CT (PMCT) in 19 adults with SDH. SDH volume, midline shift, and hematoma density were measured on both AMCT and PMCT and their differences assessed using Wilcoxon-Signed Rank Test. Spearman's Rho Test was used to assess significant correlations between the PMI and the alterations of SDH volume, midline shift, and hematoma density. RESULTS Mean time between last AMCT and PMCT was 109 h, mean PMI was 35 h. On PMCT mean midline displacement was decreased by 57% (p < 0.001); mean SDH volume was decreased by 38% (p < 0.001); and mean hematoma density was increased by 18% (p < 0.001) in comparison to AMCT. There was no correlation between the PMI and the normalization of the midline shift (p = 0.706), the reduction of SDH volume (p = 0.366), or the increase of hematoma density (p = 0.140). CONCLUSIONS This study reveals that normal postmortem changes significantly affect the extent and imaging characteristics of subdural hematoma and may therefore affect the interpretation of these findings on PMCT. Radiologists and forensic pathologists who use PMCT must be aware of these phenomena in order to correctly interpret PMCT findings in cases of subdural hemorrhages.
Resumo:
PURPOSE To determine the effect of the use of iodinated contrast agents on the formation of DNA double-strand breaks during chest computed tomography (CT). MATERIALS AND METHODS This study was approved by the institutional review board, and written informed consent was obtained from all patients. This single-center study was performed at a university hospital. A total of 179 patients underwent contrast material-enhanced CT, and 66 patients underwent unenhanced CT. Blood samples were taken from these patients prior to and immediately after CT. In these blood samples, the average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was determined with fluorescence microscopy. Significant differences between the number of foci that developed in both the presence and the absence of the contrast agent were tested by using an independent sample t test. RESULTS γH2AX foci levels were increased in both groups after CT. Patients who underwent contrast-enhanced CT had an increased amount of DNA radiation damage (mean increase ± standard error of the mean, 0.056 foci per cell ± 0.009). This increase was 107% ± 19 higher than that in patients who underwent unenhanced CT (mean increase, 0.027 foci per cell ± 0.014). CONCLUSION The application of iodinated contrast agents during diagnostic x-ray procedures, such as chest CT, leads to a clear increase in the level of radiation-induced DNA damage as assessed with γH2AX foci formation.
Resumo:
A 49 year old female presented to our Neuroendocrine Tumour (NET) centre with recurrent severe and disabling hypoglycaemia. She had previously been extensively investigated with a clinical and biochemical diagnosis of endogenous hyperinsulinemic hypoglycaemia although the source of hormonal hypersecretion could not be localised with MRI, EUS and (111) In-Octreotide scans. After extensive discussion the patient opted for blind surgical resection undergoing a pylorus-preserving pancreaticoduodenectomy in December 2010. Histological examination of the resected operative specimen demonstrated a normal pancreas with no evidence of neuroendocrine tumour. Consistent with this, post-surgery her hypoglycaemic symptoms persisted with fasting capillary blood glucose of 2.1-6.0 mmol/l with increasing hypoglycaemia unawareness. Consequently she sought alternative clinical opinions from two European Neuroendocrine Tumour Society (ENETS) Centres of Excellence who investigated her collaboratively. This article is protected by copyright. All rights reserved.
Resumo:
Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.
Resumo:
PURPOSE The present study aimed at the comparison of body height estimations from cadaver length with body height estimations according to Trotter and Gleser (1952) and Penning and Riepert (2003) on the basis of femoral F1 section measurements in post-mortem computed tomography (PMCT) images. METHODS In a post-mortem study in a contemporary Swiss population (226 corpses: 143 males (mean age: 53±17years) and 83 females (mean age: 61±20years)) femoral F1 measurements (403 femora: 199 right and 204 left; 177 pairs) were conducted in PMCT images and F1 was used for body height estimation using the equations after Trotter and Gleser (1952, "American Whites"), and Penning and Riepert (2003). RESULTS The mean observed cadaver length was 176.6cm in males and 163.6cm in females. Mean measured femoral length F1 was 47.5cm (males) and 44.1cm (females) respectively. Comparison of body height estimated from PMCT F1 measurements with body height calculated from cadaver length showed a close congruence (mean difference less than 0.95cm in males and less than 1.99cm in females) for equations both applied after Penning and Riepert and Trotter and Gleser. CONCLUSIONS Femoral F1 measurements in PMCT images are very accurate, reproducible and feasible for body height estimation of a contemporary Swiss population when using the equations after Penning and Riepert (2003) or Trotter and Gleser (1952).
Resumo:
INTRODUCTION Patient management following elective cranial surgery often includes routine postoperative computed tomography (CT). We analyzed whether a regime of early extubation and close neurological monitoring without routine CT is safe, and compared the rate of postoperative emergency neurosurgical intervention with published data. METHODS Four hundred ninety-two patients were prospectively analyzed; 360 had supra- and 132 had infratentorial lesions. Extubation within one hour after skin closure was aimed for in all cases. CT was performed within 48 hours only in cases of unexpected neurological findings. RESULTS Four-hundred sixty-nine of the 492 patients (95.3%) were extubated within one hour, 20 (4.1%) within 3 hours, and three (0.6%) within 3 to 10 hours. Emergency CT within 48 hours was performed for 43/492 (8.7%) cases. Rate of recraniotomy within 48 hours for patients with postoperative hemorrhage was 0.8% (n = 4), and 0.8% (n = 4) required placement of an external ventricular drain (EVD). Of 469 patients extubated within one hour, 3 required recraniotomy and 2 required EVD placements. Of 23 patients with delayed extubation, 1 recraniotomy and 2 EVDs were required. Failure to extubate within one hour was associated with a significantly higher risk of surgical intervention within 48 hours (rate 13.0%, p = 0.004, odds ratio 13.9, 95% confidence interval [3.11-62.37]). DISCUSSION Early extubation combined with close neurological monitoring is safe and omits the need for routine postoperative CT. Patients not extubated within one hour do need early CT, since they had a significantly increased risk of requiring emergency neurosurgical intervention. TRIAL REGISTRATION ClinicalTrials.gov NCT01987648.