413 resultados para stent-grafts
Resumo:
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.
Resumo:
The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.
Resumo:
Approximately 20% of leg ulcers remain unresponsive to the best conservative standard of care. So far, these patients could either receive conventional skin grafts or had to accept their intractable wound. Skin substitutes from cell culture may represent a promising alternative to heal a major part of these patients on a non-surgical, potentially more cost-effective basis.
Resumo:
The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.
Resumo:
Background—Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results—A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions—Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents.
Resumo:
Objectives This study sought to compare the unrestricted use of everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary intervention. Background It is unclear whether there are differences in safety and efficacy between EES and SES during long-term follow-up. Methods Using propensity score matching, clinical outcome was compared among 1,342 propensity score–matched pairs of patients treated with EES and SES. The primary outcome was a composite of death, MI, and target vessel revascularization. Results The median follow-up was 1.5 years with a maximum of 3 years. The primary outcome occurred in 14.9% of EES- and 18.0% of SES-treated patients up to 3 years (hazard ratio [HR]: 0.83, 95% confidence interval [CI]: 0.68 to 1.00, p = 0.056). All-cause mortality (6.0% vs. 6.5%, HR: 0.92, 95% CI: 0.68 to 1.25, p = 0.59) was similar, risks of myocardial infarction (MI) (3.3% vs. 5.0%, HR: 0.62, 95% CI: 0.42 to 0.92, p = 0.017), and target vessel revascularization (7.0% vs. 9.6%, HR: 0.75, 95% CI: 0.57 to 0.99, p = 0.039) were lower with EES than SES. Definite stent thrombosis (ST) (HR: 0.30, 95% CI: 0.12 to 0.75, p = 0.01) was less frequent among patients treated with EES. The reduced rate of MI with EES was explained in part by the lower risk of definite ST and the corresponding decrease in events associated with ST (HR: 0.25, 95% CI: 0.08 to 0.75, p = 0.013). Conclusions The unrestricted use of EES appears to be associated with improved clinical long-term outcome compared with SES. Differences in favor of EES are driven in part by a lower risk of MI associated with ST.
Resumo:
Objectives: We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Background: Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Methods: Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). Results: At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50–0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). Conclusions: SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients.
Resumo:
The objective of the study was to determine the feasibility of generating a biodegradable, stem cell-loaded osteogenic composite graft from human placenta. Initially, a scaffold from human chorion membrane was produced. Human placenta mesenchymal stem cells (MSCs) derived from either first-trimester chorionic villi or term chorion membrane were differentiated osteogenically on this scaffold. Outgrowth, adherence, and osteogenic differentiation of cells were assessed by immunohistochemistry (IHC), scanning electron microscopy, protein expression, and real-time polymerase chain reaction (RT-PCR). Our results showed that a cell-free extracellular matrix scaffold can be generated from human chorion. Seeded MSCs densely adhered to that scaffold and were osteogenically differentiated. Calcium and alkaline phosphatase were detected in the cell-scaffold constructs as a proof of mineralization and findings were confirmed by IHC and RT-PCR results. This study shows for the first time that generation of an osteogenic composite graft using placental tissue is feasible. It might allow therapeutic application of autologous or allogeneic grafts in congenital skeletal defects by means of a composite graft.
Resumo:
Angioplasty and stenting of the IA have been reported with high technical and clinical success rates, low complication rates and good mid-term patency rates. Different antegrade or retrograde endovascular catheter-based approaches and combinations with surgical exposure of the CCA are used. The purpose of this study was to determine safety, efficacy and mid-term clinical and radiological outcome of the stent-assisted treatment of atherosclerotic stenotic disease of the IA with special focus on the different technical approaches.
Resumo:
Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy.
Resumo:
Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.
Resumo:
Background: Autogenous bone grafts obtained by different harvesting techniques behave differently during the process of graft consolidation; the underlying reasons are however not fully understood. One theory is that harvesting techniques have an impact on the number and activity of the transplanted cells which contribute to the process of graft consolidation. Materials and Methods: To test this assumption, porcine bone grafts were harvested with four different surgical procedures: bone mill, piezosurgery, bone drilling (bone slurry), and bone scraper. After determining cell viability, the release of molecules affecting bone formation and resorption was assessed by reverse transcription polymerase chain reaction and immunoassay. The mitogenic and osteogenic activity of the conditioned media was evaluated in a bioassay with isolated bone cells. Results: Cell viability and the release of molecules affecting bone formation were higher in samples harvested by bone mill and bone scraper when compared with samples prepared by bone drilling and piezosurgery. The harvesting procedure also affected gene expression, for example, bone mill and bone scraper samples revealed significantly higher expression of growth factors such as bone morphogenetic protein-2 and vascular endothelial growth factor compared with the two other modalities. Receptor activator of nuclear factor kappa B ligand expression was lowest in bone scraper samples. Conclusion: These data can provide a scientific basis to better understand the impact of harvesting techniques on the number and activity of transplanted cells, which might contribute to the therapeutic outcome of the augmentation procedure.
Resumo:
The repair of critical-sized bony defects remains a challenge in the fields of implantology, maxillofacial surgery and orthopaedics. As an alternative bone-defect filler to autologous bone grafts, deproteinized bovine bone (DBB) is highly osteoconductive and clinically now widely used. However, this product suffers from the disadvantage of not being intrinsically osteoinductive. In the present study, this property was conferred by coating DBB with a layer of calcium phosphate into which bone morphogenetic protein 2 (BMP-2) was incorporated. Granules of DBB bearing a coating-incorporated depot of BMP-2--together with the appropriate controls (DBB bearing a coating but no BMP-2; uncoated DBB bearing adsorbed BMP-2; uncoated DBB bearing no BMP-2)--were implanted subcutaneously in rats. Five weeks later, the implants were withdrawn for a histomorphometric analysis of the volume densities of (i) bone, (ii) bone marrow, (iii) foreign-body giant cells and (iv) fibrous capsular tissue. Parameters (i) and (ii) were highest, whilst parameters (iii) and (iv) were lowest in association with DBB bearing a coating-incorporated depot of BMP-2. Hence, this mode of functionalization not only confers DBB with the property of osteoinductivity but also improves its biocompatibility--thus dually enhancing its clinical potential in the repair of bony defects.
Resumo:
The authors report on the use of 5 French diagnostic catheters to deliver a stent-on-a-wire system during a double vessel coronary intervention.
Resumo:
Background The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. Methods We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. Findings 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66–1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35–1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06–0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51–1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (pinteraction=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41–1·80) during the first year and 0·17 (0·04–0·78) during subsequent years (pinteraction=0·049). Interpretation Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. Funding Biosensors Europe SA, Switzerland.