316 resultados para coronary artery bypass surgery
Resumo:
AIMS: We investigated whether myeloid-related protein 8/14 complex (MRP8/14) expressed by infiltrating monocytes and granulocytes may represent a mediator and early biomarker of acute coronary syndromes (ACS). METHODS AND RESULTS: Immunohistochemistry of coronary thrombi was done in 41 ACS patients. Subsequently, levels of MRP8/14 were assessed systemically in 75 patients with ACS and culprit lesions, with stable coronary artery disease (CAD), or with normal coronary arteries. In a subset of patients, MRP8/14 was measured systemically and at the site of coronary occlusion. Macrophages and granulocytes, but not platelets stained positive for MRP8/14 in 76% of 41 thrombi patients. In ACS, local MRP8/14 levels [22.0 (16.2-41.5) mg/L] were increased when compared with systemic levels [13.4 (8.1-14.7) mg/L, P = 0.03]. Systemic levels of MRP8/14 were markedly elevated [15.1 (12.1-21.8) mg/L, P = 0.001] in ACS when compared with stable CAD [4.6 (3.5-7.1) mg/L] or normals [4.8 (4.0-6.3) mg/L]. Using a cut-off level of 8 mg/L, MRP8/14 but not myoglobin or troponin, identified ACS presenting within 3 h from symptom onset. CONCLUSION: In ACS, MRP8/14 is markedly expressed at the site of coronary occlusion by invading phagocytes. The occurrence of elevated MRP8/14 in the systemic circulation prior to markers of myocardial necrosis makes it a prime candidate for the detection of unstable plaques and management of ACS.
Resumo:
Although rare, stent thrombosis remains a severe complication after stent implantation owing to its high morbidity and mortality. Since the introduction of drug-eluting stents (DES), most interventional centers have noted stent thrombosis up to 3 years after implantation, a complication rarely seen with bare-metal stents. Some data from large registries and meta-analyses of randomized trials indicate a higher risk for DES thrombosis, whereas others suggest an absence of such a risk. Several factors are associated with an increased risk of stent thrombosis, including the procedure itself (stent malapposition and/or underexpansion, number of implanted stents, stent length, persistent slow coronary blood flow, and dissections), patient and lesion characteristics, stent design, and premature cessation of antiplatelet drugs. Drugs released from DES exert distinct biological effects, such as activation of signal transduction pathways and inhibition of cell proliferation. As a result, although primarily aimed at preventing vascular smooth muscle cell proliferation and migration (ie, key factors in the development of restenosis), they also impair reendothelialization, which leads to delayed arterial healing, and induce tissue factor expression, which results in a prothrombogenic environment. In the same way, polymers used to load these drugs have been associated with DES thrombosis. Finally, DES impair endothelial function of the coronary artery distal to the stent, which potentially promotes the risk of ischemia and coronary occlusion. Although several reports raise the possibility of a substantially higher risk of stent thrombosis in DES, evidence remains inconclusive; as a consequence, both large-scale and long-term clinical trials, as well as further mechanistic studies, are needed. The present review focuses on the pathophysiological mechanisms and pathological findings of stent thrombosis in DES.
Resumo:
BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.
Resumo:
BACKGROUND: The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. METHODS: On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. RESULTS: CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. CONCLUSIONS: In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure.
Resumo:
BACKGROUND: Dysfunction of the nitric oxide pathway is implicated in peripheral arterial disease. Nitric oxide synthase (NOS) isoforms and NOS activity were studied in muscle from patients with critical leg ischaemia (CLI). Alterations in NOS during revascularization surgery were also assessed. METHODS: Muscle biopsies were taken from patients with CLI undergoing amputation and also from patients undergoing femorodistal bypass at the start of surgery, after arterial clamping and following reperfusion. The presence of NOS within muscle sections was confirmed using reduced nicotinamide adenine dinucleotide phosphate diaphorase histochemistry. NOS isoform distribution was studied by immunohistochemistry. NOS mRNA and protein levels were measured using real-time reverse transcriptase-polymerase chain reaction and western blotting. NOS activity was assessed with the citrulline assay. RESULTS: All three NOS isoforms were found in muscle, associated with muscle fibres and microvessels. NOS I and III protein expression was increased in CLI (P = 0.041). During revascularization, further ischaemia and reperfusion led to a rise in NOS III protein levels (P = 0.008). NOS activity was unchanged. CONCLUSION: Alterations in NOS I and III occurred in muscle from patients with CLI and further changes occurred during bypass surgery.
Resumo:
OBJECTIVES: To examine differences in risk factor (RF) management between peripheral artery disease (PAD) and coronary artery (CAD) or cerebrovascular disease (CVD), as well as the impact of RF control on major 1-year cardiovascular (CV) event rates. METHODS: The REACH Registry recruited >68000 outpatients aged >/=45 years with established atherothrombotic disease or >/=3 RFs for atherothrombosis. The predictors of RF control that were evaluated included: (1) patient demographics, (2) mode of PAD diagnosis, and (3) concomitant CAD and/or CVD. RESULTS: RF control was less frequent in patients with PAD (n=8322), compared with those with CAD or CVD (but no PAD, n=47492) [blood pressure; glycemia; total cholesterol; smoking cessation (each P<0.001)]. Factors independently associated with optimal RF control in patients with PAD were male gender (OR=1.9); residence in North America (OR=3.5), Japan (OR=2.5) or Latin America (OR=1.5); previous coronary revascularization (OR=1.3); and statin use (OR=1.4); whereas prior leg amputation was a negative predictor (OR=0.7) (P<0.001). Optimal RF control was associated with fewer 1-year CV ischemic symptoms or events. CONCLUSIONS: Patients with PAD do not achieve RF control as frequently as individuals with CAD or CVD. Improved RF control is associated with a positive impact on 1-year CV event rates.
Resumo:
BACKGROUND: Diabetes mellitus (DM) and renal insufficiency (RI) were shown to be associated with an obstructive lesion pattern favouring distal lower limb arterial segments in patients with peripheral arterial disease (PAD). We hypothesized that presence of DM is associated with pronounced involvement of the tibioperoneal arteries, whereas RI predominantly affects the pedal arch. PATIENTS AND METHODS: A consecutive series of PAD patients (mean age 75 +/- 10 years, 40 women) with RI alone (n = 15), RI and DM (n = 25), DM alone (n = 25) and without RI or DM (n = 25) underwent diagnostic angiography. We analyzed the obstructive burden of different segments of the infrageniculate arterial tree using the Bollinger score as well as accessibility of pedal arteries for bypass surgery. RESULTS: In patients with DM and in patients with RI the mean total obstructive burden was higher in pedal as compared to tibioperoneal arteries (9.79 +/- 4.60 vs. 6.99 +/- 3.45, p = 0.03;10.50 +/- 5.53 vs. 6.88 +/- 4.12, p = 0.05, respectively). However, rates of patency of at least one pedal artery were significantly lower in patients with RI and RI/DM as compared to controls (47% and 48% vs. 80%, respectively; p = 0.007), whereas patency was comparable between patients with diabetes alone and controls (72% vs. 80%, ns). Rates of viability of pedal arteries as an attachment site for distal bypass was 80%, 68%, 47% and 44% in controls, patients with DM alone, RI alone and RI/DM, respectively (p = 0.0042). CONCLUSIONS: In contrast to previous anecdotal observations, both DM and RI are associated with a high atherosclerotic burden of the pedal arch in the present angiographic series. The presence of RI, however, is associated with a lower patency of the pedal arch as compared to the presence of DM alone, and more than fifty percent patients are unsuitable for distal bypass grafting.
Resumo:
BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.
Resumo:
We describe the case of a 59-year-old man who had aortic regurgitation and a hypoplastic aortic valve and for whom an echocardiography evaluation revealed a vascular tumor in the roof of the left atrium, which was suspected to be a hemangioma. After undergoing preoperative invasive catheter coronary angiography, echocardiography, and multislice computed tomography examinations, the patient underwent an aortic miniroot replacement. Intraoperative findings confirmed the findings of the preoperative evaluations. The tumor, although macroscopically verified as a hemangioma, was not resected because of the tumor's position and size, and the threat of uncontrollable bleeding. After an uneventful postoperative clinical course, a subsequent successful transcatheter coil occlusion of the coronary fistula from the left circumflex coronary artery was performed as an alternative to surgical resection of the tumor. This case emphasizes the future role of a multimodality hybrid approach for diagnosis, planning (different 2- and 3-dimensional imaging modalities), and treatment in the form of combining interventional (transcatheter) and surgical (open heart) techniques, which could optimize different treatment strategies. This approach could be further improved by increasing the installations of hybrid operating rooms.
Resumo:
We review the case of a 46-year-old man who underwent elective percutaneous coronary intervention and stenting of the left anterior descending artery and right coronary artery with two sirolimus- and paclitaxel-eluting stents. Four days after angioplasty, he was readmitted with cardiogenic shock due to acute anterior and inferior myocardial infarction. Coronary angiography revealed subacute thrombosis of both stents, and balloon dilation was performed successfully thereafter. The follow-up investigations revealed that the patient was a carrier of factor V Leiden. We hereby discuss the importance of factor V Leiden as the most common cause of hypercoagulable state and its probable role in acute and subacute coronary stent thrombosis in drug-eluting stents.
Resumo:
BACKGROUND: The link between decreased heart rate variability (HRV) and atherosclerosis progression is elusive. We hypothesized that reduced HRV relates to increased levels of prothrombotic factors previously shown to predict coronary risk. METHODS: We studied 257 women (aged 56 +/- 7 years) between 3 and 6 months after an acute coronary event and obtained very low frequency (VLF), low frequency (LF), and high frequency (HF) power, and LF/HF ratio from 24-hour ambulatory ECG recordings. Plasma levels of activated clotting factor VII (FVIIa), fibrinogen, von Willebrand factor antigen (VWF:Ag), and plasminogen activator inhibitor-1 (PAI-1) activity were determined, and their levels were aggregated into a standardized composite index of prothrombotic activity. RESULTS: In bivariate analyses, all HRV indices were inversely correlated with the prothrombotic index explaining between 6% and 14% of the variance (p < 0.001). After controlling for sociodemographic factors, index event, menopausal status, cardiac medication, lifestyle factors, self-rated health, metabolic variables, and heart rate, VLF power, LF power, and HF power explained 2%, 5%, and 3%, respectively, of the variance in the prothrombotic index (p < 0.012). There were also independent relationships between VLF power and PAI-1 activity, between LF power and fibrinogen, VWF:Ag, and PAI-1 activity, between HF power and FVIIa and fibrinogen, and between the LF/HF power ratio and PAI-1 activity, explaining between 2% and 3% of the respective variances (p < 0.05). CONCLUSIONS: Decreased HRV was associated with prothrombotic changes partially independent of covariates. Alteration in autonomic function might contribute to prothrombotic activity in women with coronary artery disease (CAD).
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.
Resumo:
BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Recent studies have suggested placental growth factor (PlGF) and vascular endothelial growth factor (VEGF) as promising new biomarkers for risk stratification in acute coronary syndromes (ACS). However, little is known about the influence of percutaneous coronary intervention (PCI) on circulating PlGF and VEGF levels. METHODS: Thirty-five patients with ACS, 27 patients with stable coronary artery disease (sCAD), and nine healthy controls were enrolled in the study. Although all patients with ACS and 14 patients with stable angina pectoris underwent PCI, 13 patients with coronary artery disease required no revascularization (sCAD). PlGF and VEGF plasma concentrations were measured by immunoassay during and at the end of PCI and coronary angiography. RESULTS: Plasma PlGF levels were comparable in patients with ACS and sCAD on admission. Although coronary angiography or heparin alone did not alter PlGF and VEGF levels, immediately after PCI a dramatic increase was seen in circulating PlGF and a decrease in VEGF, which was independent of the clinical presentation of the patients, heparin administration, or the angiographic procedure itself, but was associated with the extent of coronary artery disease and the amount of the injected contrast media. In-vitro experiments revealed that radiocontrast agents induced the release of PlGF from endothelial cells without altering PlGF mRNA expression. CONCLUSION: Patients undergoing PCI exhibit an increase in circulating PlGF, probably caused by posttranslational modifications of radiocontrast agents in endothelial cells. Therefore, analysis of plasma PlGF and VEGF levels may consider the timing of blood sampling with respect to PCI and contrast media exposure.
Resumo:
OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.