241 resultados para SURGICAL-TREATMENT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study reports on the surgical and prosthodontic rehabilitation of 46 patients, 31 male and 15 female, after resection of oral tumors. The treatment was carried out from 2004 to 2007 at the Department of Prosthodontics, University of Bern, with a follow-up time of 3 to 6 years. The average age at diagnosis was 54 years. 76% of all tumors were squamous cell carcinoma, followed by adenocarcinoma. Resection of the tumors including soft and/or hard tissues was performed in all patients. 80% of them additionally underwent radiotherapy and 40% chemotherapy. A full block resection of the mandible was perfomed in 23 patients, and in 10 patients, the tumor resection resulted in an oronasal communication. 29 patients underwent grafting procedures, mostly consisting of a free fibula flap transplant. To enhance the prosthetic treatment outcome and improve the prosthesis stability, a total of 114 implants were placed. However, 14 implants were not loaded because they failed during the healing period or the patient could not complete the final treatment with the prostheses. The survival rate of the implants reached 84.2% after 4 to 5 years. Many patients were only partially dentate before the tumors were detected, and further teeth had to be extracted in the course of the tumor therapy. Altogether, 31 jaws became or remained edentulous. Implants provide stability and may facilitate the adaptation to the denture, but their survival rate was compromised. Mostly, patients were fitted with removable prostheses with obturators in the maxilla and implant-supported complete dentures with bars in the mandible. Although sequelae of tumor resection are similar in many patients, the individual intermaxillary relations, facial morphology and functional capacity vary significantly. Thus, individual management is required for prosthetic rehabilitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of the therapy is mechanical and functional stabilization of high dislocated hips with dysplasia coxarthrosis using total hip arthroplasty (THA). INDICATIONS Developmental dysplasia of the hip (DDH) in adults, symptomatic dysplasia coxarthrosis, high hip dislocation according to Crowe type III/IV, and symptomatic leg length inequality. CONTRAINDICATIONS Cerebrospinal dysfunction, muscular dystrophy, apparent disturbance of bone metabolism, acute or chronic infections, and immunocompromised patients. SURGICAL TECHNIQUE With the patient in a lateral decubitus position an incision is made between the anterior border of the gluteus maximus muscle and the posterior border of the gluteus medius muscle (Gibson interval). Identification of the sciatic nerve to protect the nerve from traction disorders by visual control. After performing trochanter flip osteotomy, preparation of the true actetabulum if possible. Implantation of the reinforcement ring, preparation of the femur and if necessary for mobilization, resection until the trochanter minor. Test repositioning under control of the sciatic nerve. Finally, refixation of the trochanteric crest. POSTOPERATIVE MANAGEMENT During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with maximum flexion of 70°. No active abduction and passive adduction over the body midline. Maximum weight bearing 10-15 kg for 8 weeks, subsequently, first clinical and radiographic follow-up and deep venous thrombosis prophylaxis until full weight bearing. RESULTS From 1995 to 2012, 28 THAs of a Crow type IV high hip-dislocation were performed in our institute. Until now 14 patients have been analyzed during a follow-up of 8 years in 2012. Mid-term results showed an improvement of the postoperative clinical score (Merle d'Aubigné score) in 86 % of patients. Good to excellent results were obtained in 79 % of cases. Long-term results are not yet available. In one case an iatrogenic neuropraxia of the sciatic nerve was observed and after trauma a redislocation of the arthroplasty appeared in another case. In 2 cases an infection of the THA appeared 8 and 15 months after index surgery. No pseudoarthrosis of the trochanter or aseptic loosening was noticed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impingement of the lesser trochanter on the ischium or the posterior acetabular rim is not a frequent pathology, but has recently received increased recognition. We have seen 14 cases over a period of 14 years, but concentrate on eight hips showing complex deformities revealing similar characteristics. All eight hips had a residual Perthes or a Perthes-like disease with an elliptically deformed femoral head, but a congurent joint a short or absent femoral neck, a high riding greater trochanter, and a reduced vertical distance between the head and the lesser trochanter. Impingement took place between the lesser trochanter and the ischium or the posteroinferior acetabular border, but was hardly recognisable due to the predominant intraarticular impingement of the nonspherical femoral head and the extraarticular impingement of the greater trochanter. In three cases the impingement showed reproducible subluxation of the hip. While in our hips, excision was the preferred treatment for impingement due to an oversized lesser trochanter, distal advancement was used in the hips with the Perthes morphology; the surgical time was not longer. The overall clinical results in this group however were dominated by a substantial increase in the range of motion (ROM), dependent mainly on the achieved contour of the femoral head and the relative lengthening of the neck. Strength of active hip flexion was normal. Recurrent subluxation disappeared and no complications were recorded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Intraoperative radiofrequency (RF) ablation is an effective treatment of atrial fibrillation (AF). However, secondary arrhythmias late after ablation may complicate the patient's course. We report on the incidence, mechanisms, and treatment of gap-related atrial flutter and other secondary arrhythmias during long-term follow-up. METHODS AND RESULTS In 129 patients who underwent intraoperative RF ablation with placement of left atrial linear lesions using minimally invasive surgical techniques, secondary arrhythmias were analyzed during long-term follow-up (20 +/- 6 months). Transient atrial arrhythmias during the first 3 postoperative months were excluded. In 8 (6.2%) of 129 patients, sustained stable secondary arrhythmias were documented. Left atrial, gap-related atrial flutter was observed in 4 patients (3.1%). The flutter was treated by percutaneous RF ablation in 3 patients (2.3%) and with drugs in 1 patient (0.8%). In 2 patients (1.6%), right atrial isthmus-dependent atrial flutter occurred and was treated successfully by percutaneous RF ablation. In 2 patients (1.6%), ectopic right atrial tachycardias occurred and were treated with percutaneous RF ablation. CONCLUSION Late after intraoperative RF ablation of atrial fibrillation, three types of stable secondary arrhythmias were observed in 6% of patients: left atrial gap-related atrial flutter, right atrial isthmus-dependent atrial flutter, and ectopic atrial tachycardia. Gaps after intraoperative RF ablation due to noncontinuous or nontransmural linear lesions may lead to stable left atrial macroreentrant tachycardias, requiring new interventional therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to evaluate if osseous correction of the femoral neck achieved arthroscopically is comparable to that achieved by surgical dislocation. METHODS We retrospectively analyzed all patients who were treated with hip arthroscopy or surgical dislocation for cam or mixed type femoroacetabular impingement (FAI) in our institution between 2006 and 2009. Inclusion criteria were complete clinical and radiologic documentation with standardized radiographs. Group 1 consisted of 66 patients (49 female patients, mean age 33.8 years) treated with hip arthroscopy. Group 2 consisted of 135 patients (91 male patients, mean age 31.2 years) treated with surgical hip dislocation. We compared the preoperative and postoperative alpha and gamma angles, as well as the triangular index. Mean follow-up was 16.7 months (range, 2 to 79 months). RESULTS In group 1, the mean alpha angle improved from 60.7° preoperatively to 47.8° postoperatively (P < .001) and the mean gamma angle improved from 47.3° to 44.5° (P < .001). Over time, the preoperative mean alpha angle increased from 56.3° in 2006 to 67.5° in 2009, whereas the postoperative mean alpha angle decreased from 51.2° in 2006 to 47.5° in 2009. In group 2, the mean alpha angle improved from 75.3° preoperatively to 44.8° postoperatively (P < .001), and the mean gamma angle improved from 65.1° to 52.2° (P < .001). Arthroscopic revision of intra-articular adhesions was performed in 4 patients (6.1%) in group 1 and 16 patients (12%) in group 2. Three patients (2.2%) in group 2 underwent revision for nonunion of the greater trochanter. CONCLUSIONS Osseous correction of cam-type FAI with hip arthroscopy is comparable to the correction achieved by surgical hip dislocation. There is a significant learning curve for hip arthroscopy, with postoperative osseous correction showing improved results with increasing surgical experience. LEVEL OF EVIDENCE Level III, retrospective comparative study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surgical management of symptomatic femoroacetabular impingement (FAI) generally is indicated after the failure of a trial of nonsurgical treatment. Surgical planning includes an assessment of the labrochondral pathology as well as of the acetabular and proximal femoral bony deformity. Advanced articular cartilage disease generally is associated with poorer outcomes. Surgical hip dislocation and hip arthroscopy have been used, with favorable early outcomes and low complication rates. Careful patient selection is important in predicting the success of the surgical management of symptomatic FAI. A trial of nonsurgical management generally is recommended, but limited information exists regarding its success. The early outcomes of both open and arthroscopic surgical techniques demonstrate significant improvement in most patients, with relatively low rates of complications. Because poorer clinical outcomes are associated with more advanced articular cartilage degeneration, improved strategies for the earlier identification and disease staging of symptomatic patients may enhance the long-term outcomes of both nonsurgical and surgical management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose We compared the long-term results of minimally invasive endourological intervention and open surgical revision in patients with a nonmalignant ureteroileal stricture. Materials and Methods We retrospectively evaluated the records of 74 patients (85 renal units) treated for unilateral or bilateral nonmalignant ureteroileal strictures. Overall, 96 endourological and 35 open surgical procedures were performed. Balloon dilatation and Acucise® or Ho:YAG laser endoureterotomy were used as minimally invasive endourological interventions. Open surgical revision with stricture resection and open ureteroileal end-to-side-reanastomosis was the alternate therapy. Treatment success was defined as radiological normalization or improvement of upper urinary tract morphology combined with absent flank pain, infection, ureteral stents or percutaneous nephrostomies. Results Median followup was 29 months (range 2 to 177). The overall success rate was 26% (25 of 96 cases) for endourological intervention vs 91% (32 of 35) for open surgical revision (p <0.001). Subgroup analysis showed a significant difference in the success rate of minimally invasive endourological interventions vs open surgical revision for strictures greater than 1 cm (3 of 52 cases or 6% vs 19 of 22 or 86%, p <0.001). The success rate of endourological and open surgical procedures for strictures 1 cm or less was 50% (22 of 44 cases) and 100% (13 of 13), respectively. After adjusting for multiple preoperative stricture characteristics, only stricture length was strongly and inversely associated with a successful outcome (p <0.001). Conclusions Open surgical revision produces better results than minimally invasive endourological intervention for ureteroileal strictures, particularly those greater than 1 cm. The success rate of endourological intervention is acceptable only for ureteroileal strictures 1 cm or less. Therefore, ureteroileal strictures greater than 1 cm should be primarily managed by open surgical revision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CASE DESCRIPTION A 7-year-old 573-kg (1,261 -lb) Swiss Warmblood gelding was evaluated because of signs of acute abdominal pain. CLINICAL FINDINGS Physical examination revealed a markedly distended abdomen with subjectively reduced borborygmi in all abdominal quadrants. A large, gas-distended viscus was present at the pelvic brim preventing complete palpation of the abdomen per rectum. Ultrasonographic evaluation could not be safely performed in the initial evaluation because of severe signs of abdominal pain. TREATMENT AND OUTCOME Ventral midline celiotomy was performed, and right dorsal displacement of the ascending colon was corrected. Progressive signs of abdominal pain after surgery prompted repeat ventral midline celiotomy, and small intestinal incarceration in a large, radial mesojejunal rent was detected. The incarceration was reduced, but the defect was not fully accessible for repair via the celiotomy. Repair of the mesenteric defect was not attempted, and conservative management was planned after surgery; however, signs of colic returned. A standard laparoscopic approach was attempted from both flanks in the standing patient, but the small intestine could not be adequately mobilized for full evaluation of the rent. Hand-assisted laparoscopic surgery (HALS) allowed identification and reduction of jejunal incarceration and repair of the mesenteric rent. Although minor ventral midline incisional complications were encountered, the horse recovered fully. CLINICAL RELEVANCE HALS techniques should be considered for repair of mesenteric rents in horses. In the horse of this report, HALS facilitated identification, evaluation, and repair of a large radial mesenteric rent that was not accessible from a ventral median celiotomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Mortality of patients with acute liver failure (ALF) is still unacceptably high. Available liver support systems are still of limited success at improving survival. A new type of albumin dialysis, the Hepa Wash® system, was newly introduced. We evaluated the new liver support system as well as the Molecular Adsorbent Recycling System (MARS) in an ischemic porcine model of ALF. METHODS In the first study animals were randomly allocated to control (n=5) and Hepa Wash (n=6) groups. In a further pilot study, two animals were treated with the MARS-system. All animals received the same medical and surgical procedures. An intraparenchymal intracranial pressure was inserted. Hemodynamic monitoring and goal-directed fluid therapy using the PiCCO system was done. Animals underwent functional end-to-side portacaval shunt and ligation of hepatic arteries. Treatment with albumin dialysis was started after fall of cerebral perfusion pressure to 45 mmHg and continued for 8 h. RESULTS All animals in the Hepa Wash group survived the 13-hour observation period, except for one that died after stopping treatment. Four of the control animals died within this period (p=0.03). Hepa Wash significantly reduced impairment of cerebral perfusion pressure (23±2 vs. 10±3 mmHg, p=0.006) and mean arterial pressure (37±1 vs. 24±2 mmHg, p=0.006) but had no effect on intracranial pressure (14±1 vs. 15±1 mmHg, p=0.72). Hepa Wash also enhanced cardiac index (4.94±0.32 vs. 3.36±0.25 l/min/m2, p=0.006) and renal function (urine production, 1850 ± 570 vs. 420 ± 180 ml, p=0.045) and eliminated water soluble (creatinine, 1.3±0.2 vs. 3.2±0.3 mg/dl, p=0.01; ammonia 562±124 vs. 1382±92 μg/dl, p=0.006) and protein-bound toxins (nitrate/nitrite 5.54±1.57 vs. 49.82±13.27 μmol/l, p=0.01). No adverse events that could be attributed to the Hepa Wash treatment were observed. CONCLUSIONS Hepa Wash was a safe procedure and improved multiorgan system failure in pigs with ALF. The survival benefit could be the result of ameliorating different organ functions in association with the detoxification capacity of water soluble and protein-bound toxins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Refractory ascites (RA) affects 10% of patients with advanced cirrhosis and ascites. Usual therapy includes large volume paracentesis, and in selected patients, a transjugular portosystemic shunt (TIPS). These therapies may be associated with increased morbidity: paracentesis may induce circulatory dysfunction and impair quality of life and TIPS may induce encephalopathy and is associated with increased mortality in patients with severe liver dysfunction. We present the results of a multicenter, non-randomized trial to assess the safety and efficacy of a new automated pump system for treatment of RA. METHODS: Forty patients at 9 centers (February 2010-June 2011) received an implanted pump for the automated removal of ascites from the peritoneal cavity into the bladder, from where it was eliminated through normal urination. Patients were followed-up for 6months. The primary study outcome was safety. Secondary outcomes included recurrence of tense ascites and pump performance. RESULTS: Surgical complications occurred early in the study and became less frequent. The pump system removed 90% of the ascites and significantly reduced the median number of large volume paracentesis per month [3.4 (range 1-6) vs. 0.2 (range 0-4); p <0.01]. Cirrhosis-related adverse events decreased along follow-up. CONCLUSIONS: The automated pump seems an efficacious tool to move out ascites from the peritoneal cavity to the bladder. Its safety is still moderate, but a broad use in different countries will improve the surgical technique as well as the medical surveillance. A prospective randomized clinical trial vs. large volume paracentesis is underway to confirm these preliminary results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To assess long-term clinical outcomes of consecutive high-risk patients with severe aortic stenosis according to treatment allocation to transcatheter aortic valve implantation (TAVI), surgical aortic valve replacement (SAVR) or medical treatment (MT). METHODS Patients with severe aortic stenosis were consecutively enrolled into a prospective single centre registry. RESULTS Among 442 patients (median age 83 years, median STS-score 4.7) allocated to MT (n=78), SAVR (n=107), or TAVI (n=257) all-cause mortality amounted to 81%, 37% and 43% after a median duration of follow-up of 3.9 years (p<0.001). Rates of major adverse cerebro-cardiovascular events were lower in patients undergoing SAVR or TAVI as compared with MT (SAVR vs MT: HR 0.31, 95% CI 0.21 to 0.46) (TAVI vs MT: HR 0.34, 95% CI 0.25 to 0.46), with no significant difference between SAVR and TAVI (HR 0.88, 95% CI 0.62 to 1.25). Whereas SAVR (HR 0.39, 95% CI 0.24 to 0.61), TAVI (HR 0.37, 95% CI 0.26 to 0.52), and female gender (HR 0.72, 95% CI 0.53 to 0.99) were associated with improved survival, body mass index ≤20 kg/m(2) (HR 1.60, 95% CI 1.04 to 2.47), diabetes (HR 1.48, 95% CI 1.03 to 2.12), peripheral vascular disease (HR 2.01, 95% CI 1.44 to 2.81), atrial fibrillation (HR 1.74, 95% CI 1.28 to 2.37) and pulmonary hypertension (HR 1.43, 95% CI 1.03 to 2.00) were identified as independent predictors of mortality. CONCLUSIONS Among high-risk patients with severe aortic stenosis, long-term clinical outcome through 5 years was comparable between patients allocated to SAVR or TAVI. In contrast, patients with MT had a dismal prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five cats with large, distal extremity abrasion wounds were treated with an autogenous, full-thickness, mesh skin graft. Survival of the mesh grafts in all five cats was considered between 90 and 100%. Successful grafting requires asepsis, an adequately prepared recipient bed consisting of healthy granulation tissue, proper harvesting and preparation of the graft, meticulous surgical technique and strict postoperative care. Factors that are essential for the survival of skin grafts include good contact between the graft and the recipient bed, normal tension on the sutured graft, strict immobilization after grafting and prevention of accumulation of blood or serum under the graft. Meshing the graft provides more graft flexibility over uneven surfaces and allows adequate drainage. In contrast to previous proposals, the authors recommend no bandage change before the fourth day after grafting. Full-thickness mesh skin grafting can be used to successfully treat large distal skin wounds in cats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate the effect of metal implants in proton radiotherapy, dose distributions of different, clinically relevant treatment plans have been measured in an anthropomorphic phantom and compared to treatment planning predictions. The anthropomorphic phantom, which is sliced into four segments in the cranio-caudal direction, is composed of tissue equivalent materials and contains a titanium implant in a vertebral body in the cervical region. GafChromic® films were laid between the different segments to measure the 2D delivered dose. Three different four-field plans have then been applied: a Single-Field-Uniform-Dose (SFUD) plan, both with and without artifact correction implemented, and an Intensity-Modulated-Proton-Therapy (IMPT) plan with the artifacts corrected. For corrections, the artifacts were manually outlined and the Hounsfield Units manually set to an average value for soft tissue. Results show a surprisingly good agreement between prescribed and delivered dose distributions when artifacts have been corrected, with > 97% and 98% of points fulfilling the gamma criterion of 3%/3 mm for both SFUD and the IMPT plans, respectively. In contrast, without artifact corrections, up to 18% of measured points fail the gamma criterion of 3%/3 mm for the SFUD plan. These measurements indicate that correcting manually for the reconstruction artifacts resulting from metal implants substantially improves the accuracy of the calculated dose distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.