355 resultados para stent thrombosis
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.
Resumo:
BACKGROUND: Studies continue to identify percutaneous coronary intervention procedural volume both at the institutional level and at the operator level as being strongly correlated with outcome. High-volume centers have been defined as those that perform >400 percutaneous coronary intervention procedures per year. The relationship between drug-eluting stent procedural volume and outcome is unknown. We investigated this relationship in the German Cypher Registry. METHODS AND RESULTS: The present analysis included 8201 patients treated with sirolimus-eluting stents between April 2002 and September 2005 in 51 centers. Centers that recruited >400 sirolimus-eluting stent patients in this time period were considered high-volume centers; those with 150 to 400 patients were considered intermediate-volume centers; and those with <150 patients were designated as low-volume centers. The primary end point was all death, myocardial infarction, and target-vessel revascularization at 6 months. This end point occurred in 11.3%, 12.1%, and 9.0% of patients in the low-, intermediate-, and high-volume center groups, respectively (P=0.0001). There was no difference between groups in the rate of target-vessel revascularization (P=0.2) or cerebrovascular accidents (P=0.5). The difference in death/myocardial infarction remained significant after adjustment for baseline factors (odds ratio 1.85, 95% confidence interval 1.31 to 2.59, P<0.001 for low-volume centers; odds ratio 1.69, 95% confidence interval 1.29 to 2.21, P<0.001 for intermediate-volume centers). Patient and lesion selection, procedural features, and postprocedural medications differed significantly between groups. CONCLUSIONS: The volume of sirolimus-eluting stent procedures performed on an institutional level was inversely related to death and myocardial infarction but not to target-vessel revascularization at 6-month follow-up. Safety issues are better considered in high-volume centers. These findings have important public health policy implications.
Resumo:
A 49-year-old male patient presented with a paravalvular leakage 18 years after aortic valve replacement. The patient received a mechanical valve and was weaned uneventfully from cardiopulmonary bypass. After a drop in the pressure curve of the left radial artery an additional line was placed in the proximal ascending aorta showing normal systemic pressure. Transesophageal echocardiography showed a massive circular thrombosis of the distal aortic arch. The patient received a covered stent to expand the residual aortic lumen and left the hospital in good health.
Resumo:
BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.
Resumo:
BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.
Resumo:
This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.
Resumo:
Aims: Early-generation drug-eluting stent (DES) overlap (OL) is associated with impaired long-term clinical outcomes whereas the impact of OL with newer-generation DES is unknown. Our aim was to assess the impact of OL on long-term clinical outcomes among patients treated with newer-generation DES. Methods and results: We analysed the three-year clinical outcomes of 3,133 patients included in a prospective DES registry according to stent type (sirolimus-eluting stents [SES; N=1,532] versus everolimus-eluting stents [EES; N=1,601]), and the presence or absence of OL. The primary outcome was a composite of death, myocardial infarction (MI), and target vessel revascularisation (TVR). The primary endpoint was more common in patients with OL (25.1%) than in those with multiple DES without OL (20.8%, adj HR=1.46, 95% CI: 1.03-2.09) and patients with a single DES (18.8%, adj HR=1.74, 95% CI: 1.34-2.25, p<0.001) at three years. A stratified analysis by stent type showed a higher risk of the primary outcome in SES with OL (28.7%) compared to other SES groups (without OL: 22.6%, p=0.04; single DES: 17.6%, p<0.001), but not between EES with OL (22.3%) and other EES groups (without OL: 18.5%, p=0.30; single DES: 20.4%, p=0.20). Conclusions: DES overlap is associated with impaired clinical outcomes during long-term follow-up. Compared with SES, EES provide similar clinical outcomes irrespective of DES overlap status.
Resumo:
AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.
Resumo:
OBJECTIVE to compare the vascular healing process between the sirolimus-eluting NEVO and the everolimus-eluting Xience stent by optical coherence tomography (OCT) at 1-year follow-up. BACKGROUND Presence of durable polymer on a drug-eluting metallic stent may be the basis of an inflammatory reaction with abnormal healing response. The NEVO stent, having a bioresorbable polymer eluted by reservoir technology, may overcome this problem. METHODS All consecutive patients, who received NEVO or Xience stent implantation between September 2010 and October 2010 in our institution, were included. Vascular healing was assessed at 1-year as percentage of uncovered struts, neointimal thickness (NIT), in-stent/stent area obstruction and pattern of neointima. RESULTS A total 47 patients (2:1 randomization, n = 32 NEVO, n = 15 Xience) were included. Eighteen patients underwent angiographic follow-up (eight patients with nine lesions for NEVO vs. 10 patients with 11 lesions for Xience). The angiographic late loss was numerically higher but not statistically different in NEVO compared with Xience treated lesions (0.38 ± 0.47 mm vs. 0.18 ± 0.27 mm; P = 0.171). OCT analysis of 4,912 struts demonstrated similar rates of uncovered struts (0.5 vs. 0.7%, P = 0.462), higher mean NIT (177.76 ± 87.76 µm vs. 132.22 ± 30.91 µm; P = 0.170) and in stent/stent area obstruction (23.02 ± 14.74% vs. 14.17 ± 5.94%, P = 0.120) in the NEVO as compared with Xience. CONCLUSION The NEVO stent with a reservoir technology seems to exhibit more neointimal proliferation as compared to Xience stent. The findings of our study, which currently represent the unique data existing on this reservoir technology, would need to be confirmed in a large population.
Resumo:
OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.
Resumo:
Oral contraceptives containing synthetic oestrogens have been used successfully as birth control for > 40 years and are currently prescribed to > 100 million women worldwide. Several new progestins have been introduced and the third generation of progestins has now been available for two decades. Oral contraceptives are prescribed over a prolonged period of time and therefore substantially impact on hormonal, metabolic and plasmatic functions. Oral contraceptives increase the risk for venous thrombosis and pulmonary embolism, particularly if associated with confounding factors, such as genetic predisposition, smoking, hypertension or obesity. The risk of developing coronary artery disease is also increased in users with cardiovascular risk factors. This article discusses mechanistic and clinical issues and reviews the need for novel approaches targeting the considerable side effects in order to reduce cardiovascular morbidity in women using oral contraceptives.