319 resultados para coronary artery bypass
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.
Resumo:
BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Recent studies have suggested placental growth factor (PlGF) and vascular endothelial growth factor (VEGF) as promising new biomarkers for risk stratification in acute coronary syndromes (ACS). However, little is known about the influence of percutaneous coronary intervention (PCI) on circulating PlGF and VEGF levels. METHODS: Thirty-five patients with ACS, 27 patients with stable coronary artery disease (sCAD), and nine healthy controls were enrolled in the study. Although all patients with ACS and 14 patients with stable angina pectoris underwent PCI, 13 patients with coronary artery disease required no revascularization (sCAD). PlGF and VEGF plasma concentrations were measured by immunoassay during and at the end of PCI and coronary angiography. RESULTS: Plasma PlGF levels were comparable in patients with ACS and sCAD on admission. Although coronary angiography or heparin alone did not alter PlGF and VEGF levels, immediately after PCI a dramatic increase was seen in circulating PlGF and a decrease in VEGF, which was independent of the clinical presentation of the patients, heparin administration, or the angiographic procedure itself, but was associated with the extent of coronary artery disease and the amount of the injected contrast media. In-vitro experiments revealed that radiocontrast agents induced the release of PlGF from endothelial cells without altering PlGF mRNA expression. CONCLUSION: Patients undergoing PCI exhibit an increase in circulating PlGF, probably caused by posttranslational modifications of radiocontrast agents in endothelial cells. Therefore, analysis of plasma PlGF and VEGF levels may consider the timing of blood sampling with respect to PCI and contrast media exposure.
Resumo:
OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.
Resumo:
AIMS The aim of our study in patients with coronary artery disease (CAD) and present, or absent, myocardial ischaemia during coronary occlusion was to test whether (i) left ventricular (LV) filling pressure is influenced by the collateral circulation and, on the other hand, that (ii) its resistance to flow is directly associated with LV filling pressure. METHODS AND RESULTS In 50 patients with CAD, the following parameters were obtained before and during a 60 s balloon occlusion: LV, aortic (Pao) and coronary pressure (Poccl), flow velocity (Voccl), central venous pressure (CVP), and coronary flow velocity after coronary angioplasty (V(Ø-occl)). The following variables were determined and analysed at 10 s intervals during occlusion, and at 60 s of occlusion: LV end-diastolic pressure (LVEDP), velocity-derived (CFIv) and pressure-derived collateral flow index (CFIp), coronary collateral (Rcoll), and peripheral resistance index to flow (Rperiph). Patients with ECG signs of ischaemia during coronary occlusion (insufficient collaterals, n = 33) had higher values of LVEDP over the entire course of occlusion than those without ECG signs of ischaemia during occlusion (sufficient collaterals, n = 17). Despite no ischaemia in the latter, there was an increase in LVEDP from 20 to 60 s of occlusion. In patients with insufficient collaterals, CFIv decreased and CFIp increased during occlusion. Beyond an occlusive LVEDP > 27 mmHg, Rcoll and Rperiph increased as a function of LVEDP. CONCLUSION Recruitable collaterals are reciprocally tied to LV filling pressure during occlusion. If poorly developed, they affect it via myocardial ischaemia; if well grown, LV filling pressure still increases gradually during occlusion despite the absence of ischaemia indicating transmission of collateral perfusion pressure to the LV. With low, but not high, collateral flow, resistance to collateral as well as coronary peripheral flow is related to LV filling pressure in the high range.
Resumo:
OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve. RESULTS 16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66). CONCLUSIONS Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.
Resumo:
BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.
Resumo:
The functional relevance of coronary collaterals in humans has yet to be fully explored. Several studies demonstrated a protective role of collaterals in patients with coronary artery disease. On the other hand, negative aspects of well-developed coronary collaterals have been reported, e.g. a higher rate of restenosis following coronary angioplasty, or a redistribution of blood via collaterals away from the myocardial area in need towards normally perfused areas (coronary steal). In the past, the coronary collateral circulation has been assessed only qualitatively, using visual angiographic or nuclear imaging methods. With the recent advent of intracoronary Doppler and pressure-transducers, quantitative assessment of functional parameters of the coronary circulation has become feasible. This article reviews ongoing research in the field of coronary collaterals in humans, concerning their exact determination, the positive and negative aspects of their structure as well as their functional aspects.
Resumo:
OBJECTIVES The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Inc., Santa Rosa, California) in patients with coronary artery disease and diabetes. BACKGROUND The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. METHODS We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. RESULTS The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p < 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with noninsulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). CONCLUSIONS The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with noninsulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Medtronic RESOLUTE Clinical Trial; NCT00248079; Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; The Medtronic RESOLUTE US Clinical Trial (R-US); NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [R-Int]; NCT00752128; RESOLUTE Japan-The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent [RJ]; NCT00927940).
Resumo:
OBJECTIVE To expand the limited information on the prognostic impact of quantitatively obtained collateral function in patients with coronary artery disease (CAD) and to estimate causality of such a relation. DESIGN Prospective cohort study with long-term observation of clinical outcome. SETTING University Hospital. PATIENTS One thousand one hundred and eighty-one patients with chronic stable CAD undergoing 1771 quantitative, coronary pressure-derived collateral flow index measurements, as obtained during a 1-min coronary balloon occlusion (CFI is the ratio between mean distal coronary occlusive pressure and mean aortic pressure both subtracted by central venous pressure). Subgroup of 152 patients included in randomised trials on the longitudinal effect of different arteriogenic protocols on CFI. INTERVENTIONS Collection of long-term follow-up information on clinical outcome. MAIN OUTCOME MEASURES All-cause mortality and major adverse cardiac events. RESULTS Cumulative 15-year survival rate was 48% in patients with CFI<0.25 and 65% in the group with CFI≥0.25 (p=0.0057). Cumulative 10-year survival rate was 75% in patients without arteriogenic therapy and 88% (p=0.0482) in the group with arteriogenic therapy and showing a significant increase in CFI at follow-up. By proportional hazard analysis, the following variables predicted increased all-cause mortality: age, low CFI, left ventricular end-diastolic pressure and number of vessels with CAD. CONCLUSIONS A well-functioning coronary collateral circulation independently predicts lowered mortality in patients with chronic CAD. This relation appears to be causal, because augmented collateral function by arteriogenic therapy is associated with prolonged survival.
Resumo:
OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.
Resumo:
This study investigated the contribution of estrogen receptors (ERs) alpha and beta for epicardial coronary artery function, vascular NO bioactivity, and superoxide (O(2)(-)) formation. Porcine coronary rings were suspended in organ chambers and precontracted with prostaglandin F(2alpha) to determine direct effects of the selective ER agonists 4,4',4''-(4-propyl-[(1)H]pyrazole-1,3,5-triyl)tris-phenol (PPT) or 2,3-bis(4-hydroxyphenyl)-propionitrile (DPN) or the nonselective ER agonist 17beta-estradiol. Indirect effects on contractility to U46619 and relaxation to bradykinin were assessed and effects on NO, nitrite, and O(2)(-) formation were measured in cultured cells. Within 5 minutes, selective ERalpha activation by PPT, but not 17beta-estradiol or the ERbeta agonist DPN, caused rapid, NO-dependent, and endothelium-dependent relaxation (49+/-5%; P<0.001 versus ethanol). PPT also caused sustained endothelium- and NO-independent vasodilation similar to 17beta-estradiol after 60 minutes (72+/-3%; P<0.001 versus ethanol). DPN induced endothelium-dependent NO-independent relaxation via endothelium-dependent hyperpolarization (40+/-4%; P<0.01 versus ethanol). 17beta-Estradiol and PPT, but not DPN, attenuated the responses to U46619 and bradykinin. All of the ER agonists increased NO and nitrite formation in vascular endothelial but not smooth muscle cells and attenuated vascular smooth muscle cell O(2)(-) formation (P<0.001). ERalpha activation had the most potent effects on both nitrite formation and inhibiting O(2)(-) (P<0.05). These data demonstrate novel and differential mechanisms by which ERalpha and ERbeta activation control coronary artery vasoreactivity in males and females and regulate vascular NO and O(2)(-) formation. The findings indicate that coronary vascular effects of sex hormones differ with regard to affinity to ERalpha and ERbeta, which will contribute to beneficial and adverse effects of hormone replacement therapy.
Resumo:
AIMS To investigate a pressure-controlled intermittent coronary sinus occlusion (PICSO) system in an ischaemia/reperfusion model. METHODS AND RESULTS We randomly assigned 18 pigs subjected to 60 minutes ischaemia by left anterior descending (LAD) coronary artery balloon occlusion to PICSO (n=12, groups A and B) or to controls (n=6, group C). PICSO started 10 minutes before (group A), or 10 minutes after (group B) reperfusion and was maintained for 180 minutes. A continuous drop of distal LAD pressure was observed in group C. At 180 minutes of reperfusion, LAD diastolic pressure was significantly lower in group C compared to groups A and B (p=0.02). LAD mean pressure was significantly less than the systemic arterial mean pressure in group C (p=0.02), and the diastolic flow slope was flat, compared to groups A and B (p=0.03). IgG and IgM antibody deposition was significantly higher in ischaemic compared to non-ischaemic tissue in group C (p<0.05). Significantly more haemorrhagic lesions were seen in the ischaemic myocardium of group C, compared to groups A and B (p=0.002). The necrotic area differed non-significantly among groups. CONCLUSIONS PICSO was safe and effective in improving coronary perfusion pressure and reducing antibody deposition consistent with reduced microvascular obstruction and ischaemia/reperfusion injury.
Resumo:
Temporary transcoronary unipolar pacing is a validated simple, effective, and safe alternative to temporary transvenous pacing of the right ventricle for the treatment of relevant bradyarrhythmias complicating percutaneous coronary intervention. We describe the use of rapid transcoronary pacing to aid precise placement of a stent in the left main coronary artery bifurcation.
Resumo:
Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist. Methods: In 45 patients a 19-lead ECG was registered during a 1-minute balloon occlusion of a coronary artery (left anterior descending artery [LAD], right coronary artery [RCA] or left circumflex artery [LCX]). ST-segment shifts and sensitivity/specificity of the leads were measured. Results: During LAD occlusion, V3 showed maximal ST-segment elevation (0.26 mV [IQR 0.16–0.33 mV], p = 0.001) and sensitivity/specificity (88% and 80%). During RCA occlusion, III showed maximal ST-elevation (0.2 mV [IQR 0.09–0.26 mV], p = 0.004), aVF had the best sensitivity/specificity (85% and 68%). During LCX occlusion, V6 showed maximal ST-segment elevation (0.04 mV [IQR 0.02–0.14 mV], p = 0.005), and sensitivity/specificity was (31%/92%) but could be improved (63%/72%) using an optimized cut-off for ischemia. Conclusion: V3, aVF and V6 show the best performance to detect transient ischemia.