247 resultados para Orthodontic mini-implants
Resumo:
BACKGROUND AND AIM So far there is little evidence from randomised clinical trials (RCT) or systematic reviews on the preferred or best number of implants to be used for the support of a fixed prosthesis in the edentulous maxilla or mandible, and no consensus has been reached. Therefore, we reviewed articles published in the past 30 years that reported on treatment outcomes for implant-supported fixed prostheses, including survival of implants and survival of prostheses after a minimum observation period of 1 year. MATERIAL AND METHODS MEDLINE and EMBASE were searched to identify eligible studies. Short and long-term clinical studies were included with prospective and retrospective study designs to see if relevant information could be obtained on the number of implants related to the prosthetic technique. Articles reporting on implant placement combined with advanced surgical techniques such as sinus floor elevation (SFE) or extensive grafting were excluded. Two reviewers extracted the data independently. RESULTS A primary search was broken down to 222 articles. Out of these, 29 studies comprising 26 datasets fulfilled the inclusion criteria. From all studies, the number of planned and placed implants was available. With two exceptions, no RCTs were found, and these two studies did not compare different numbers of implants per prosthesis. Eight studies were retrospective; all the others were prospective. Fourteen studies calculated cumulative survival rates for 5 and more years. From these data, the average survival rate was between 90% and 100%. The analysis of the selected articles revealed a clear tendency to plan 4 to 6 implants per prosthesis. For supporting a cross-arch fixed prosthesis in the maxilla, the variation is slightly greater. CONCLUSIONS In spite of a dispersion of results, similar outcomes are reported with regard to survival and number of implants per jaw. Since the 1990s, it was proven that there is no need to install as many implants as possible in the available jawbone. The overwhelming majority of articles dealing with standard surgical procedures to rehabilitate edentulous jaws uses 4 to 6 implants.
Resumo:
OBJECTIVES The generation of learning goals (LGs) that are aligned with learning needs (LNs) is one of the main purposes of formative workplace-based assessment. In this study, we aimed to analyse how often trainer–student pairs identified corresponding LNs in mini-clinical evaluation exercise (mini-CEX) encounters and to what degree these LNs aligned with recorded LGs, taking into account the social environment (e.g. clinic size) in which the mini-CEX was conducted. METHODS Retrospective analyses of adapted mini-CEX forms (trainers’ and students’ assessments) completed by all Year 4 medical students during clerkships were performed. Learning needs were defined by the lowest score(s) assigned to one or more of the mini-CEX domains. Learning goals were categorised qualitatively according to their correspondence with the six mini-CEX domains (e.g. history taking, professionalism). Following descriptive analyses of LNs and LGs, multi-level logistic regression models were used to predict LGs by identified LNs and social context variables. RESULTS A total of 512 trainers and 165 students conducted 1783 mini-CEXs (98% completion rate). Concordantly, trainer–student pairs most often identified LNs in the domains of ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation/efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710). Of the 446 LGs noted in total, the most frequently noted were ‘physical examination’ (49%) and ‘history taking’ (21%). Corresponding LNs as well as social context factors (e.g. clinic size) were found to be predictors of these LGs. CONCLUSIONS Although trainer–student pairs often agreed in the LNs they identified, many assessments did not result in aligned LGs. The sparseness of LGs, their dependency on social context and their partial non-alignment with students’ LNs raise questions about how the full potential of the mini-CEX as not only a ‘diagnostic’ but also an ‘educational’ tool can be exploited.
Resumo:
Background: Defining learning goals (LG) in alignment with learning needs (LN) is one of the key purposes of formative workplace-based assessment, but studies about this topic are scarce. Summary of Work: We analysed quantitatively and qualitatively how often trainer-student pairs identified the same LN during Mini Clinical Evaluation Exercises (Mini-CEX) in clerkships and to what degree those LNs were in line with the recorded LGs. Multilevel logistic regression models were used to predict LGs by identified LNs, controlling for context variables. Summary of Results: 512 trainers and 165 students conducted 1783 Mini-CEX (98% completion rate). Concordantly, trainer-student pairs most often identified LNs in the domains ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation / efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710), with a total of 446 LGs. Of these, the most frequent LGs were ‘physical examination’ (49% of 446 LGs) and ‘history taking’ (21%); corresponding LNs as well as context variables (e.g. clinic size) were found to be predictors of these LGs. Discussion and Conclusions: Although trainer-student pairs often agreed in their identified LNs, many assessments did not result in an aligned LG or a LG at all. Interventions are needed to enhance the proportion of (aligned) LGs in Mini-CEX in order to tap into its full potential not only as a ‘diagnostic’ but also as an ‘educational tool’. Take-home messages: The sparseness of LGs, their dependency on context variables and their partial non-alignment with students’ LNs raise the question of how the effectiveness of Mini-CEX can be further enhanced.
Resumo:
SUMMARY BACKGROUND/OBJECTIVES Orthodontic management of maxillary canine impaction (MCI), including forced eruption, may result in significant root resorption; however, the association between MCI and orthodontically induced root resorption (OIRR) is not yet sufficiently established. The purpose of this retrospective cohort study was to comparatively evaluate the severity of OIRR of maxillary incisors in orthodontically treated patients with MCI. Additionally, impaction characteristics were associated with OIRR severity. SUBJECTS AND METHODS The sample comprised 48 patients undergoing fixed-appliance treatment-24 with unilateral/bilateral MCI and 24 matched controls without impaction. OIRR was calculated using pre- and post-operative panoramic tomograms. The orientation of eruption path, height, sector location, and follicle/tooth ratio of the impacted canine were also recorded. Mann-Whitney U-test and univariate and multivariate linear mixed models were used to test for the associations of interest. RESULTS Maxillary central left incisor underwent more OIRR in the impaction group (mean difference = 0.58mm, P = 0.04). Overall, the impaction group had 0.38mm more OIRR compared to the control (95% confidence interval, CI: 0.03, 0.74; P = 0.04). However, multivariate analysis demonstrated no difference in the amount of OIRR between impaction and non-impaction groups overall. A positive association between OIRR and initial root length was observed (95% CI: 0.08, 0.27; P < 0.001). The severity of canine impaction was not found to be a significant predictor of OIRR. LIMITATIONS This study was a retrospective study and used panoramic tomograms for OIRR measurements. CONCLUSIONS This study indicates that MCI is a weak OIRR predictor. Interpretation of the results needs caution due to the observational nature of the present study.
Resumo:
Purpose.This retrospective cohort study evaluated factors for peri-implant bone level changes (ΔIBL) associated with an implant type with inner-cone implant-abutment connection, rough neck surface, and platform switching (AT). Materials and Methods. All AT placed at the Department of Prosthodontics of the University of Bern between January 2004 and December 2005 were included in this study. All implants were examined by single radiographs using the parallel technique taken at surgery (T0) and obtained at least 6 months after surgery (T1). Possible influencing factors were analysed first using t-test (normal distribution) or the nonparametric Wilcoxon test (not normal distribution), and then a mixed model q variance analysis was performed. Results. 43 patients were treated with 109 implants. Five implants in 2 patients failed (survival rate: 95.4%).Mean ΔIBL in group 1 (T1: 6–12 months after surgery) was −0.65 ± 0.82mm and −0.69 ± 0.82mm in group 2 (T1: >12 months after surgery) (
Resumo:
PURPOSE To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction. METHODS Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy. RESULTS All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris. CONCLUSIONS This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases.
Resumo:
BACKGROUND Scientific data and clinical observations appear to indicate that an adequate width of attached mucosa may facilitate oral hygiene procedures thus preventing peri-implant inflammation and tissue breakdown (eg, biologic complications). Consequently, in order to avoid biologic complications and improve long-term prognosis, soft tissue conditions should be carefully evaluated when implant therapy is planned. At present the necessity and time-point for soft tissue grafting (eg, prior to or during implant placement or after healing) is still controversially discussed while clinical recommendations are vague. OBJECTIVES To provide a review of the literature on the role of attached mucosa to maintain periimplant health, and to propose a decision tree which may help the clinician to select the appropriate surgical technique for increasing the width of attached mucosa. RESULTS The available data indicate that ideally, soft tissue conditions should be optimized by various grafting procedures either before or during implant placement or as part of stage-two surgery. In cases, where, despite insufficient peri-implant soft tissue condition (ie, lack of attached mucosa or movements caused by buccal frena), implants have been uncovered and/or loaded, or in cases where biologic complications are already present (eg, mucositis, peri-implantitis), the treatment appears to be more difficult and less predictable. CONCLUSION Soft tissue grafting may be important to prevent peri-implant tissue breakdown and should be considered when dental implants are placed. The presented decision tree may help the clinician to select the appropriate grafting technique.
Resumo:
The objective of the present review was to summarize the evidence available on the temporal sequence of hard and soft tissue healing around titanium dental implants in animal models and in humans. A search was undertaken to find animal and human studies reporting on the temporal dynamics of hard and soft tissue integration of titanium dental implants. Moreover, the influence of implant surface roughness and chemistry on the molecular mechanisms associated with osseointegration was also investigated. The findings indicated that the integration of titanium dental implants into hard and soft tissue represents the result of a complex cascade of biological events initiated by the surgical intervention. Implant placement into alveolar bone induces a cascade of healing events starting with clot formation and continuing with the maturation of bone in contact with the implant surface. From a genetic point of view, osseointegration is associated with a decrease in inflammation and an increase in osteogenesis-, angiogenesis- and neurogenesis-associated gene expression during the early stages of wound healing. The attachment and maturation of the soft tissue complex (i.e. epithelium and connective tissue) to implants becomes established 6-8 weeks following surgery. Based on the findings of the present review it can be concluded that improved understanding of the mechanisms associated with osseointegration will provide leads and targets for strategies aimed at enhancing the clinical performance of titanium dental implants.
Resumo:
OBJECTIVES The occurrence of multinucleated giant cells (MNGCs) on bone substitute materials has been recognized for a long time. However, there have been no studies linking material characteristics with morphology of the MNGCs. The aim was to analyze the qualitative differences of MNGCs on two commercially available calcium phosphate bone substitute materials retrieved from bone defects. MATERIAL AND METHODS Six defects were prepared bilaterally in the mandibular body of three mini pigs. The defects were randomly grafted with either deproteinized bovine bone mineral (DBBM) or biphasic calcium phosphate (BCP). After a healing period of four weeks, bone blocks were embedded in LR White resin. Three consecutive sections per defect were analyzed as follows: two with light microscopy using toluidine blue and tartrate-resistant acid phosphatase (TRAP) staining and one with transmission electron microscopy. RESULTS Multinucleated giant cells appeared on both biomaterials. On BCP, MNGCs had a flat morphology and were not observed in resorption lacunae. On DBBM, the MNGCs appeared more round and were often found in shallow concavities. MNGCs on both biomaterials demonstrated a varying degree of TRAP staining, with a tendency toward higher staining intensity of MNGCs on BCP. At the ultrastructural level, signs of superficial dissolution of BCP together with phagocytosis of minor fragments were observed. MNGCs on the surface of DBBM demonstrated sealing zones and ruffled borders, both features of mature osteoclasts. CONCLUSION MNGCs demonstrated distinctly different histological features depending on the bone substitute material used. Further research is warranted to understand the clinical implications of these morphological observations.
Resumo:
OBJECTIVE Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. MATERIAL AND METHODS Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days). RESULTS The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall. CONCLUSIONS Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.
Resumo:
The important task to observe the global coverage of middle atmospheric trace gases like water vapor or ozone usually is accomplished by satellites. Climate and atmospheric studies rely upon the knowledge of trace gas distributions throughout the stratosphere and mesosphere. Many of these gases are currently measured from satellites, but it is not clear whether this capability will be maintained in the future. This could lead to a significant knowledge gap of the state of the atmosphere. We explore the possibilities of mapping middle atmospheric water vapor in the Northern Hemisphere by using Lagrangian trajectory calculations and water vapor profile data from a small network of five ground-based microwave radiometers. Four of them are operated within the frame of NDACC (Network for the Detection of Atmospheric Composition Change). Keeping in mind that the instruments are based on different hardware and calibration setups, a height-dependent bias of the retrieved water vapor profiles has to be expected among the microwave radiometers. In order to correct and harmonize the different data sets, the Microwave Limb Sounder (MLS) on the Aura satellite is used to serve as a kind of traveling standard. A domain-averaging TM (trajectory mapping) method is applied which simplifies the subsequent validation of the quality of the trajectory-mapped water vapor distribution towards direct satellite observations. Trajectories are calculated forwards and backwards in time for up to 10 days using 6 hourly meteorological wind analysis fields. Overall, a total of four case studies of trajectory mapping in different meteorological regimes are discussed. One of the case studies takes place during a major sudden stratospheric warming (SSW) accompanied by the polar vortex breakdown; a second takes place after the reformation of stable circulation system. TM cases close to the fall equinox and June solstice event from the year 2012 complete the study, showing the high potential of a network of ground-based remote sensing instruments to synthesize hemispheric maps of water vapor.
Resumo:
The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7 ± 12.2; 53.3 ± 9.0 %) and SE-PSD (46.7 ± 4.5; 61.7 ± 4.9 %) as well as AM implants (20.49 ± 5.1; 43.9 ± 9.7 %) and AM-PSD implants (19.7 ± 3.5; 48.3 ± 15.6 %) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.
Resumo:
The present study examined the impact of implant surface modifications on osseointegration in an osteoporotic rodent model. Sandblasted, acid-etched titanium implants were either used directly (control) or were further modified by surface conditioning with NaOH or by coating with one of the following active agents: collagen/chondroitin sulphate, simvastatin, or zoledronic acid. Control and modified implants were inserted into the proximal tibia of aged ovariectomised (OVX) osteoporotic rats (n = 32/group). In addition, aged oestrogen competent animals received either control or NaOH conditioned implants. Animals were sacrificed 2 and 4 weeks post-implantation. The excised tibiae were utilised for biomechanical and morphometric readouts (n = 8/group/readout). Biomechanical testing revealed at both time points dramatically reduced osseointegration in the tibia of oestrogen deprived osteoporotic animals compared to intact controls irrespective of NaOH exposure. Consistently, histomorphometric and microCT analyses demonstrated diminished bone-implant contact (BIC), peri-implant bone area (BA), bone volume/tissue volume (BV/TV) and bone-mineral density (BMD) in OVX animals. Surface coating with collagen/chondroitin sulphate had no detectable impact on osseointegration. Interestingly, statin coating resulted in a transient increase in BIC 2 weeks post-implantation; which, however, did not correspond to improvement of biomechanical readouts. Local exposure to zoledronic acid increased BIC, BA, BV/TV and BMD at 4 weeks. Yet this translated only into a non-significant improvement of biomechanical properties. In conclusion, this study presents a rodent model mimicking severely osteoporotic bone. Contrary to the other bioactive agents, locally released zoledronic acid had a positive impact on osseointegration albeit to a lesser extent than reported in less challenging models.