318 resultados para Endoprothèse (stent)
Resumo:
A new era of stroke treatment may have begun with mechanical thrombectomy (MT) by fully deployed closed-cell self-expanding stents (stent-triever). Multiple case series and the first randomised controlled trials (RCTs) have now been published. More studies are under way involving large numbers of patients, which in turn has resulted in less strict "pragmatic" study protocols. Problems with current trials include a lack of standardisation in the conduct of the recanalisation procedure, the definition of primary endpoints such as the grade of arterial recanalisation and tissue reperfusion, and the post-surgical care provided. In Part 1 of this two part series, we outline the current situation and the major research questions.
Resumo:
BACKGROUND AND PURPOSE: Currently, several new stent retriever devices for acute stroke treatment are under development and early clinical evaluation. Preclinical testing under standardized conditions is an important first step to evaluate the technical performance and potential of these devices. The aim of this study was to evaluate the immediate recanalization effect, recanalization efficacy, thrombus-device interaction, and safety of a new stent retriever intended for thrombectomy in patients with acute stroke. MATERIAL AND METHODS: The pREset thrombectomy device (4 × 20 mm) was evaluated in 16 vessel occlusions in an established swine model. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval. Flow-restoration effect immediately after deployment and after 5-minute embedding time before retrieval, recanalization rate after retrieval, thromboembolic events, and complications were assessed. High-resolution FPCT was performed to illustrate thrombus-device interaction during the embedding time. RESULTS: Immediate flow restoration was achieved in 75% of occlusions. An increase or stable percentage of recanalizations during embedding time before retrieval was seen in 56.3%; a decrease, in 12.5%; reocclusion of a previously recanalized vessel, in 18.8%; and no recanalization effect at all, in 12.5%. Complete recanalization (TICI 3) after retrieval was achieved in 93.8%; partial recanalization (TICI 2b), in 6.2%. No distal thromboembolic events were observed. High-resolution FPCT illustrated entrapment of the thrombus between the stent struts and compression against the contralateral vessel wall, leading to partial flow restoration. During retrieval, the thrombus was retained in a straight position within the stent struts. CONCLUSIONS: In this experimental study, the pREset thrombus retriever showed a high recanalization rate in vivo. High-resolution FPCT allows detailed illustration of the thrombus-device interaction during embedding time and is advocated as an add-on tool to the animal model used in this study.
Resumo:
This study sought to assess stent strut coverage, malapposition, protrusion, and coronary evaginations as markers of healing 5 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), by optical coherence tomography (OCT).
Resumo:
A first case of coronary stent implantation through a 4 French diagnostic catheter is described.
Resumo:
Coronary artery disease (CAD) and atrial fibrillation (AF) are major determinants of morbidity and mortality. A combined treatment with antiplatelet agents and vitamin K antagonists limits the risk of stent thrombosis and stroke while increasing the rate of bleeding. The objective of this study was to investigate the impact of atrial fibrillation (AF) on long-term clinical outcomes in patients with CAD undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Resumo:
Drug-coated balloons (DCB) are being increasingly used in interventional cardiology and are established for the treatment of in-stent restenosis (ISR). It is unclear how effective they are in patients with de novo lesions.
Resumo:
BACKGROUND: This prospective multicenter study compared angiographic in-lesion late lumen loss in de novo native coronary artery lesions (vessel diameter range 2.25-2.75 mm, length range > or = 15 to < or = 30 mm) 8 months after the implantation of a sirolimus-eluting stent with that of similar vessels with the same drug-eluting stent or a bare stent of the SIRIUS study (historical controls). METHODS AND RESULTS: One hundred one patients (study group) were matched and compared with 323 patients receiving the bare stent (bare control group) and with 350 receiving the Cypher stent (Cypher control group) in the SIRIUS trial. Mean in-lesion late loss in the study group was lower than that in the bare control group (0.20 versus 0.76 mm, P < .0001) and not inferior to that in the Cypher control group (0.27 mm, P = .3). Adverse event rates (death and myocardial infarction) were similar between groups. At 8 months, target lesion revascularization rates were 0% in the study group, 13.2% in the bare control group (P < .001), and 4.6% in the Cypher control group (P = .03). CONCLUSIONS: The Cypher Bx Velocity stent was confirmed to be superior to the bare Bx Velocity stent in small coronary vessels in terms of in-lesion late loss 8 months after implantation.
Resumo:
BACKGROUND AND PURPOSE: Little is known about the incidence and treatment of ureteropelvic junction (UPJ) obstruction of renal grafts. We report on three cases treated by endopyelotomy. PATIENTS AND METHODS: Graft function declined in three patients 98, 135, and 144 days after kidney transplantation. Acute rejection was excluded by renal biopsy. Ultrasonography revealed a dilated collecting system, and a percutaneous nephrostomy tube was placed. An antegrade nephrostogram showed UPJ obstruction. Percutaneous antegrade endopyelotomy was performed with the cold-knife technique, and the area was stented for 6 weeks using a 14F/8.2F Smith endopyelotomy stent. RESULTS: No intraoperative or postoperative complications occurred. The endopyelotomies were successful, and the creatinine clearances returned to normal. CONCLUSION: Antegrade endopyelotomy in patients with UPJ obstruction of a renal graft is feasible and effective. Normal kidney function was restored after correction of the obstruction.
Resumo:
OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson ; Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.
Resumo:
CONTEXT: Compared with bare metal stents, sirolimus-eluting and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been compared in a prospective multicenter study. OBJECTIVE: To compare the safety and efficacy of sirolimus-eluting vs paclitaxel-eluting coronary stents. DESIGN: Prospective, randomized comparative trial (the REALITY trial) conducted between August 2003 and February 2004, with angiographic follow-up at 8 months and clinical follow-up at 12 months. SETTING: Ninety hospitals in Europe, Latin America, and Asia. PATIENTS: A total of 1386 patients (mean age, 62.6 years; 73.1% men; 28.0% with diabetes) with angina pectoris and 1 or 2 de novo lesions (2.25-3.00 mm in diameter) in native coronary arteries. INTERVENTION: Patients were randomly assigned in a 1:1 ratio to receive a sirolimus-eluting stent (n = 701) or a paclitaxel-eluting stent (n = 685). MAIN OUTCOME MEASURES: The primary end point was in-lesion binary restenosis (presence of a more than 50% luminal-diameter stenosis) at 8 months. Secondary end points included 1-year rates of target lesion and vessel revascularization and a composite end point of cardiac death, Q-wave or non-Q-wave myocardial infarction, coronary artery bypass graft surgery, or repeat target lesion revascularization. RESULTS: In-lesion binary restenosis at 8 months occurred in 86 patients (9.6%) with a sirolimus-eluting stent vs 95 (11.1%) with a paclitaxel-eluting stent (relative risk [RR], 0.84; 95% confidence interval [CI], 0.61-1.17; P = .31). For sirolimus- vs paclitaxel-eluting stents, respectively, the mean (SD) in-stent late loss was 0.09 (0.43) mm vs 0.31 (0.44) mm (difference, -0.22 mm; 95% CI, -0.26 to -0.18 mm; P<.001), mean (SD) in-stent diameter stenosis was 23.1% (16.6%) vs 26.7% (15.8%) (difference, -3.60%; 95% CI, -5.12% to -2.08%; P<.001), and the number of major adverse cardiac events at 1 year was 73 (10.7%) vs 76 (11.4%) (RR, 0.94; 95% CI, 0.69-1.27; P = .73). CONCLUSION: In this trial comparing sirolimus- and paclitaxel-eluting coronary stents, there were no differences in the rates of binary restenosis or major adverse cardiac events. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00235092.
Resumo:
BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.
Resumo:
After 75 years of invasive and over 50 years of interventional cardiology, cardiac catheter-based procedures have become the most frequently used interventions of modern medicine. Patients undergoing a percutaneous coronary intervention (PCI) outnumber those with coronary artery bypass surgery by a factor of 2 to 4. The default approach to PCI is the implantation of a (drug-eluting) stent, in spite of the fact that it improves the results of balloon angioplasty only in about 25% of cases. The dominance of stenting over conservative therapy or balloon angioplasty on one hand and bypass surgery on the other hand is a flagrant example of how medical research is digested an applied in real life. Apart from electrophysiological interventions, closure ot the patent foramen ovale and percutaneous replacement of the aortic valve in the elderly have the potential of becoming daily routine procedures in catheterization laboratories around the world. Stem cell regeneration of vessels or heart muscle, on the other hand, may remain a dream never to come true.
Resumo:
Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents.
Resumo:
OBJECTIVES: Our purpose was to make a synthesis of the available evidence on the relative efficacy and safety of 2 drug-eluting stents (DES)--sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES)--in patients with coronary artery disease. BACKGROUND: It is not known whether there are differences in late outcomes between the 2 most commonly used DES: SES and PES. METHODS: Sixteen randomized trials of SES versus PES with a total number of 8,695 patients were included in this meta-analysis. A full set of individual outcome data from 5,562 patients was also available. Mean follow-up period ranged from 9 to 37 months. The primary efficacy end point was the need for reintervention (target lesion revascularization). The primary safety end point was stent thrombosis. Secondary end points were death and recurrent myocardial infarction (MI). RESULTS: No significant heterogeneity was found across trials. Compared with PES, SES significantly reduced the risk of reintervention (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.63 to 0.87, p < 0.001) and stent thrombosis (HR 0.66; 95% CI 0.46 to 0.94, p = 0.02) without significantly impacting on the risk of death (HR 0.92; 95% CI 0.74 to 1.13, p = 0.43) or MI (HR 0.84; 95% CI 0.69 to 1.03, p = 0.10). CONCLUSIONS: Sirolimus-eluting stents are superior to PES in terms of a significant reduction of the risk of reintervention and stent thrombosis. The risk of death was not significantly different between the 2 DES, but there was a trend toward a higher risk of MI with PES, especially after the first year from the procedure.
Resumo:
OBJECTIVES: We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND: Percutaneous coronary intervention in small-vessel disease is associated with an increased risk of major adverse cardiac events (MACE). METHODS: A total of 1,012 patients were randomly assigned to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of angiographic and clinical outcome was performed up to 2 years after PCI according to size of the treated vessel (reference vessel diameter < or =2.75 vs. >2.75 mm). RESULTS: Of 1,012 patients, 370 patients (37%) with 495 lesions underwent stent implantation in small vessels only, 504 patients (50%) with 613 lesions in large vessels only, and 138 patients (14%) with 301 lesions in both small and large vessels (mixed). In patients with small-vessel stents, SES reduced MACE by 55% (10.4% vs. 21.4%; p = 0.004), mainly driven by a 69% reduction of target lesion revascularization (TLR) (6.0% vs. 17.7%; p = 0.001) compared with PES at 2 years. In patients with large- and mixed-vessel stents, rates of MACE (large: 10.4% vs. 13.1%; p = 0.33; mixed: 16.7% vs. 18.0%; p = 0.83) and TLR (large: 6.9% vs. 8.6%; p = 0.47; mixed: 16.7% vs. 15.4%; p = 0.86) were similar for SES and PES. There were no significant differences with respect to death and myocardial infarction between the 3 groups. CONCLUSIONS: Compared with PES, SES more effectively reduced MACE and TLR in small-vessel disease. Differences between SES and PES appear less pronounced in patients with large- and mixed-vessel disease. (The SIRTAX trial; http://clinicaltrials.gov/ct/show/NCT00297661?order=1; NCT00297661).