274 resultados para Valve
Resumo:
Introduction Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may result in faster left ventricular recovery. Methods We investigated clinical outcomes of high-risk patients with severe aortic stenosis undergoing medical treatment (n = 71) or TAVI (n = 256) stratified by left ventricular ejection fraction (LVEF) in a prospective single center registry. Results Twenty-five patients (35%) among the medical cohort were found to have an LVEF≤30% (mean 26.7±4.1%) and 37 patients (14%) among the TAVI patients (mean 25.2±4.4%). Estimated peri-interventional risk as assessed by logistic EuroSCORE was significantly higher in patients with severely impaired LVEF as compared to patients with LVEF>30% (medical/TAVI 38.5±13.8%/40.6±16.4% versus medical/TAVI 22.5±10.8%/22.1±12.8%, p <0.001). In patients undergoing TAVI, there was no significant difference in the combined endpoint of death, myocardial infarction, major stroke, life-threatening bleeding, major access-site complications, valvular re-intervention, or renal failure at 30 days between the two groups (21.0% versus 27.0%, p = 0.40). After TAVI, patients with LVEF≤30% experienced a rapid improvement in LVEF (from 25±4% to 34±10% at discharge, p = 0.002) associated with improved NYHA functional class at 30 days (decrease ≥1 NYHA class in 95%). During long-term follow-up no difference in survival was observed in patients undergoing TAVI irrespective of baseline LVEF (p = 0.29), whereas there was a significantly higher mortality in medically treated patients with severely reduced LVEF (log rank p = 0.001). Conclusion TAVI in patients with severely reduced left ventricular function may be performed safely and is associated with rapid recovery of systolic left ventricular function and heart failure symptoms.
Resumo:
The ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures.
Resumo:
Surgery offers several options in prevention of chronic venous insufficiency and its sequelae. Both the operation on veins with valve dysfunction to reduce reflux and the elimination of obstruction in thrombosed veins aim for the reduction of venous hypertension. Elevated venous pressure, impairment of cutaneous capillaries and a chronic inflammatory process result in sclerosis of skin and subcutaneous tissue and might proceed to the fascia resulting in a chronic compartment syndrome. Non- healing chronic venous ulcers under conservative therapy for more than three months may be treated by vein-surgery, local wound care therapy like shaving and negative pressure treatment and if necessary by lowering of elevated intracompartimental pressure by fasciotomy or even fasciectomy.
Resumo:
Sinotubular junction dilation is one of the most frequent pathologies associated with aortic root incompetence. Hence, we create a finite element model considering the whole root geometry; then, starting from healthy valve models and referring to measures of pathological valves reported in the literature, we reproduce the pathology of the aortic root by imposing appropriate boundary conditions. After evaluating the virtual pathological process, we are able to correlate dimensions of non-functional valves with dimensions of competent valves. Such a relation could be helpful in recreating a competent aortic root and, in particular, it could provide useful information in advance in aortic valve sparing surgery.
Resumo:
It is not well known if the size of the ascending thoracic aorta at presentation predicts features of presentation, management, and outcomes in patients with acute type B aortic dissection. The International Registry of Acute Aortic Dissection (IRAD) database was queried for all patients with acute type B dissection who had documentation of ascending thoracic aortic size at time of presentation. Patients were categorized according to ascending thoracic aortic diameters ≤4.0, 4.1 to 4.5, and ≥4.6 cm. Four hundred eighteen patients met inclusion criteria; 291 patients (69.6%) were men with a mean age of 63.2 ± 13.5 years. Ascending thoracic aortic diameter ≤4.0 cm was noted in 250 patients (59.8%), 4.1 to 4.5 cm in 105 patients (25.1%), and ≥4.6 cm in 63 patients (15.1%). Patients with an ascending thoracic aortic diameter ≥4.6 cm were more likely to be men (p = 0.01) and have Marfan syndrome (p <0.001) and known bicuspid aortic valve disease (p = 0.003). In patients with an ascending thoracic aorta ≥4.1 cm, there was an increased incidence of surgical intervention (p = 0.013). In those with an ascending thoracic aorta ≥4.6 cm, the root, ascending aorta, arch, and aortic valve were more often involved in surgical repair. Patients with an ascending thoracic aorta ≤4.0 were more likely to have endovascular therapy than those with larger ascending thoracic aortas (p = 0.009). There was no difference in overall mortality or cause of death. In conclusion, ascending thoracic aortic enlargement in patients with acute type B aortic dissection is common. Although its presence does not appear to predict an increased risk of mortality, it is associated with more frequent open surgical intervention that often involves replacement of the proximal aorta. Those with smaller proximal aortas are more likely to receive endovascular therapy.
Resumo:
Construction of a continent catheterizable urinary reservoir or an orthotopic bladder substitute requires substantial bowel resection, which can cause changes in bowel transit time. The reported incidence of chronic diarrhea after ileocecal resection is about 20%. Studies assessing bowel function after resection of 55-60 cm of ileum without compromising the ileocecal valve are scarce, and long-term results have not been reported.
Resumo:
A 77-year-old woman underwent aortic valve replacement and coronary bypass grafting in 2007 in the Emirates. Evolution was uneventful until December 2011. After repeated episodes of unspecific infections, a computed tomographic scan showed a large pseudoaneurysm of the distal ascending aorta. The site of aortic rupture was closed with a Gore-Tex patch and a Staphylococcus aureus infection treated appropriately. Two months later, a small cutaneous lesion on the cranial part of the sternotomy started bleeding. Computed tomographic scan demonstrated recurrence of a false aneurysm with erosion of the sternum and a large subcutaneous hematoma caused by the fistula. The patient was transferred to our institution. The challenges of this case included safe surgical approach (sternotomy, cannulation, perfusion, cerebral protection) as well as complete removal and extensive debridement of the infected material and reconstruction of the aortic arch. Using fully biological material, reconstruction of the ascending aorta and proximal arch was successfully performed.
Resumo:
Patients with severe aortic stenosis at increased surgical risk continue to experience compromised long-term survival despite successful transcatheter aortic valve implantation. We used time-related pathways in a multistate analysis to identify predictors of adverse long-term outcome in patients who underwent transcatheter aortic valve implantation.
Resumo:
Aims Cardiac grafts from non-heartbeating donors (NHBDs) could significantly increase organ availability and reduce waiting-list mortality. Reluctance to exploit hearts from NHBDs arises from obligatory delays in procurement leading to periods of warm ischemia and possible subsequent contractile dysfunction. Means for early prediction of graft suitability prior to transplantation are thus required for development of heart transplantation programs with NHBDs. Methods and Results Hearts (n = 31) isolated from male Wistar rats were perfused with modified Krebs-Henseleit buffer aerobically for 20 min, followed by global, no-flow ischemia (32°C) for 30, 50, 55 or 60 min. Reperfusion was unloaded for 20 min, and then loaded, in working-mode, for 40 min. Left ventricular (LV) pressure was monitored using a micro-tip pressure catheter introduced via the mitral valve. Several hemodynamic parameters measured during early, unloaded reperfusion correlated significantly with LV work after 60 min reperfusion (p<0.001). Coronary flow and the production of lactate and lactate dehydrogenase (LDH) also correlated significantly with outcomes after 60 min reperfusion (p<0.05). Based on early reperfusion hemodynamic measures, a composite, weighted predictive parameter, incorporating heart rate (HR), developed pressure (DP) and end-diastolic pressure, was generated and evaluated against the HR-DP product after 60 min of reperfusion. Effective discriminating ability for this novel parameter was observed for four HR*DP cut-off values, particularly for ≥20 *103 mmHg*beats*min−1 (p<0.01). Conclusion Upon reperfusion of a NHBD heart, early evaluation, at the time of organ procurement, of cardiac hemodynamic parameters, as well as easily accessible markers of metabolism and necrosis seem to accurately predict subsequent contractile recovery and could thus potentially be of use in guiding the decision of accepting the ischemic heart for transplantation.
Resumo:
Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement (SAVR) for patients with symptomatic severe aortic stenosis (AS) and a high operative risk. Risk stratification plays a decisive role in the optimal selection of therapeutic strategies for AS patients. The accuracy of contemporary surgical risk algorithms for AS patients has spurred considerable debate especially in the higher risk patient population. Future trials will explore TAVI in patients at intermediate operative risk. During the design of the SURgical replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trial, a novel concept of risk stratification was proposed based upon age in combination with a fixed number of predefined risk factors, which are relatively prevalent, easy to capture and with a reasonable impact on operative mortality. Retrospective application of this algorithm to a contemporary academic practice dealing with clinically significant AS patients allocates about one-fourth of these patients as being at intermediate operative risk. Further testing is required for validation of this new paradigm in risk stratification. Finally, the Heart Team, consisting of at least an interventional cardiologist and cardiothoracic surgeon, should have the decisive role in determining whether a patient could be treated with TAVI or SAVR.
Resumo:
BACKGROUND: The arterial switch operation (ASO) is currently the treatment of choice in neonates with transposition of the great arteries (TGA). The outcome in childhood is encouraging but only limited data for long-term outcome into adulthood exist. METHODS AND RESULTS: We studied 145 adult patients (age>16, median 25years) with ASO followed at our institution. Three patients died in adulthood (mortality 2.4/1000-patient-years). Most patients were asymptomatic and had normal left ventricular function. Coronary lesions requiring interventions were rare (3 patients) and in most patients related to previous surgery. There were no acute coronary syndromes. Aortic root dilatation was frequent (56% patients) but rarely significant (>45mm in 3 patients, maximal-diameter 49mm) and appeared not to be progressive. There were no acute aortic events and no patient required elective aortic root surgery. Progressive neo-aortic-valve dysfunction was not observed in our cohort and only 1 patient required neo-aortic-valve replacement. Many patients (42.1%), however, had significant residual lesions or required reintervention in adulthood. Right ventricular outflow tract lesions or dysfunction of the neo-pulmonary-valve were frequent and 8 patients (6%) required neo-pulmonary-valve replacement. Cardiac interventions during childhood (OR 3.0, 95% CI 1.7-5.4, P<0.0001) were strong predictors of outcome (cardiac intervention/significant residual lesion/death) in adulthood. CONCLUSIONS: Adult patients with previous ASO remain free of acute coronary or aortic complications and have low mortality. However, a large proportion of patients require re-interventions or present with significant right sided lesions. Life-long cardiac follow-up is, therefore, warranted. Periodic noninvasive surveillance for coronary complications appears to be safe in adult ASO patients.
Acute hyponatremia after cardioplegia by histidine-tryptophane-ketoglutarate - a retrospective study
Resumo:
Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.
Resumo:
OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.
Resumo:
Cerebrospinal fluid (CSF) shunts carry a high risk of complications. Infections represent a major cause of shunt failure. Diagnosis and therapy of such infections are complicated by the formation of bacterial biofilms attached to shunt surfaces. This study correlated the pathophysiology and clinical course of biofilm infections with microscopical findings on the respective shunts. Surface irregularities, an important risk-factor for shunt colonisation with bacteria, were found to increase over time because of silicone degradation. Scanning electron-microscopy (SEM) documented residual biological material (dead biofilm), which can further promote extant bacterial adhesion, on newly manufactured shunts. Clinical course and SEM both documented bacterial dissemination against CSF flow and the monodirectional valve. In all cases, biofilms grew on both the inner and outer surfaces of the shunts. Microscopy and conventional culture detected all bacterial shunt infections. Analyses of 16S rDNA sequences using conserved primers identified bacteria in only one of three cases, probably because of previous formalin fixation of the samples.
Resumo:
OBJECTIVE: Adequacy of organ perfusion depends on sufficient oxygen supply in relation to the metabolic needs. The aim of this study was to evaluate the relationship between gradients of free energy change, and the more commonly used parameter for the evaluation of the adequacy of organ perfusion, such as oxygen-extraction in patients undergoing valve replacement surgery using normothermic cardiopulmonary bypass (CPB). METHODS: In 43 cardiac patients, arterial, mixed venous, and hepato-venous blood samples were taken synchronously after induction of anaesthesia (preCPB), during CPB, and 2 and 7 h after admission to the intensive care unit (ICU+2, ICU+7). Blood gas analysis, cardiac output, and hepato-splanchnic blood flow were measured. Free energy change gradients between mixed venous and arterial (-deltadeltaG(v - a)) and hepato-venous and arterial (-deltadeltaG(hv - a)) compartments were calculated. MEASUREMENTS AND RESULTS: Cardiac index (CI) increased from 1.9 (0.7) to 2.8 (1.3) L/min/m (median, inter-quartile range) (p = 0.001), and hepato-splanchnic blood flow index (HBFI) from 0.6 (0.22) to 0.8 (0.53) L/min/m (p = 0.001). Despite increasing flow, systemic oxygen extraction increased after CPB from 24 (10)% to 35 (10)% at ICU+2 (p = 0.002), and splanchnic oxygen extraction increased during CPB from 37 (19)% to 52 (14)% (p = 0.001), and remained high thereafter. After CPB, high splanchnic and systemic gradients of free energy change gradients were associated with high splanchnic and systemic oxygen extraction, respectively (p = 0.001, 0.033, respectively). CONCLUSION: Gradients of free energy change may be helpful in characterising adequacy of perfusion in cardiac surgery patients independently from measurements or calculations of data from oxygen transport.