327 resultados para Mediastinitis, coronary artery bypass graft, antimicrobial prophylaxis
Meta-analysis: diagnostic performance of low-radiation-dose coronary computed tomography angiography
Resumo:
A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.
Resumo:
Animal experiments have shown that the coronary circulation is pressure distensible, i.e., myocardial blood volume (MBV) increases with perfusion pressure. In humans, however, corresponding measurements are lacking so far. We sought to quantify parameters reflecting coronary distensibility such as MBV and coronary resistance (CR) during and after coronary angioplasty. Thirty patients with stable coronary artery disease underwent simultaneous coronary perfusion pressure assessment and myocardial contrast echocardiography (MCE) of 37 coronary arteries and their territories during and after angioplasty. MCE yielded MBV and myocardial blood flow (MBF; in ml · min(-1) · g(-1)). Complete data sets were obtained in 32 coronary arteries and their territories from 26 patients. During angioplasty, perfusion pressure, i.e., coronary occlusive pressure, and MBV varied between 9 and 57 mmHg (26.9 ± 11.9 mmHg) and between 1.2 and 14.5 ml/100 g (6.7 ± 3.7 ml/100 g), respectively. After successful angioplasty, perfusion pressure and MBV increased significantly (P < 0.001 for both) and varied between 64 and 118 mmHg (93.5 ± 12.8 mmHg) and between 3.7 and 17.3 ml/100 g (9.8 ± 3.4 ml/100 g), respectively. Mean MBF increased from 31 ± 20 ml · min(-1) · g(-1) during coronary occlusion, reflecting collateral flow, to 121 ± 33 ml · min(-1) · g(-1) (P < 0.01), whereas mean CR, i.e., the ratio of perfusion pressure and MBF, decreased by 20% (P < 0.001). In conclusion, the human coronary circulation is pressure distensible. MCE allows for the quantification of CR and MBV in humans.
Resumo:
The preferred initial treatment for patients with stable coronary artery disease is the best available medical therapy. We hypothesized that in patients with functionally significant stenoses, as determined by measurement of fractional flow reserve (FFR), percutaneous coronary intervention (PCI) plus the best available medical therapy would be superior to the best available medical therapy alone.
Resumo:
The prognostic relevance of quantitative an intracoronary occlusive electrocardiographic (ECG) ST-segment shift and its determinants have not been investigated in humans. In 765 patients with chronic stable coronary artery disease, the following simultaneous quantitative measurements were obtained during a 1-minute coronary balloon occlusion: intracoronary ECG ST-segment shift (recorded by angioplasty guidewire), mean aortic pressure, mean distal coronary pressure, and mean central venous pressure (CVP). Collateral flow index (CFI) was calculated as follows: (mean distal coronary pressure minus CVP)/(mean aortic pressure minus CVP). During an average follow-up duration of 50 ± 34 months, the cumulative mortality rate from all causes was significantly lower in the group with an ST-segment shift <0.1 mV (n = 89) than in the group with an ST-segment shift ≥0.1 mV (n = 676, p = 0.0211). Factors independently related to intracoronary occlusive ECG ST-segment shift <0.1 mV (r(2) = 0.189, p <0.0001) were high CFI (p <0.0001), intracoronary occlusive RR interval (p = 0.0467), right coronary artery as the ischemic region (p <0.0001), and absence of arterial hypertension (p = 0.0132). "High" CFI according to receiver operating characteristics analysis was ≥0.217 (area under receiver operating characteristics curve 0.647, p <0.0001). In conclusion, absence of ECG ST-segment shift during brief coronary occlusion in patients with chronic coronary artery disease conveys a decreased mortality and is directly influenced by a well-developed collateral supply to the right versus left coronary ischemic region and by the absence of systemic hypertension in a patient's history.
Resumo:
AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.
Resumo:
AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.
Resumo:
OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.
Resumo:
BACKGROUND: This prospective multicenter study compared angiographic in-lesion late lumen loss in de novo native coronary artery lesions (vessel diameter range 2.25-2.75 mm, length range > or = 15 to < or = 30 mm) 8 months after the implantation of a sirolimus-eluting stent with that of similar vessels with the same drug-eluting stent or a bare stent of the SIRIUS study (historical controls). METHODS AND RESULTS: One hundred one patients (study group) were matched and compared with 323 patients receiving the bare stent (bare control group) and with 350 receiving the Cypher stent (Cypher control group) in the SIRIUS trial. Mean in-lesion late loss in the study group was lower than that in the bare control group (0.20 versus 0.76 mm, P < .0001) and not inferior to that in the Cypher control group (0.27 mm, P = .3). Adverse event rates (death and myocardial infarction) were similar between groups. At 8 months, target lesion revascularization rates were 0% in the study group, 13.2% in the bare control group (P < .001), and 4.6% in the Cypher control group (P = .03). CONCLUSIONS: The Cypher Bx Velocity stent was confirmed to be superior to the bare Bx Velocity stent in small coronary vessels in terms of in-lesion late loss 8 months after implantation.
Resumo:
AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.
Resumo:
CONTEXT: The effect of a percutaneous coronary intervention (PCI) on the long-term prognosis of patients with silent ischemia after a myocardial infarction (MI) is not known. OBJECTIVE: To determine whether PCI compared with drug therapy improves long-term outcome of asymptomatic patients with silent ischemia after an MI. DESIGN, SETTING, AND PARTICIPANTS: Randomized, unblinded, controlled trial (Swiss Interventional Study on Silent Ischemia Type II [SWISSI II]) conducted from May 2, 1991, to February 25, 1997, at 3 public hospitals in Switzerland of 201 patients with a recent MI, silent myocardial ischemia verified by stress imaging, and 1- or 2-vessel coronary artery disease. Follow-up ended on May 23, 2006. INTERVENTIONS: Percutaneous coronary intervention aimed at full revascularization (n = 96) or intensive anti-ischemic drug therapy (n = 105). All patients received 100 mg/d of aspirin and a statin. MAIN OUTCOME MEASURES: Survival free of major adverse cardiac events defined as cardiac death, nonfatal MI, and/or symptom-driven revascularization. Secondary measures included exercise-induced ischemia and resting left ventricular ejection fraction during follow-up. RESULTS: During a mean (SD) follow-up of 10.2 (2.6) years, 27 major adverse cardiac events occurred in the PCI group and 67 events occurred in the anti-ischemic drug therapy group (adjusted hazard ratio, 0.33; 95% confidence interval, 0.20-0.55; P<.001), which corresponds to an absolute event reduction of 6.3% per year (95% confidence interval, 3.7%-8.9%; P<.001). Patients in the PCI group had lower rates of ischemia (11.6% vs 28.9% in patients in the drug therapy group at final follow-up; P = .03) despite fewer drugs. Left ventricular ejection fraction remained preserved in PCI patients (mean [SD] of 53.9% [9.9%] at baseline to 55.6% [8.1%] at final follow-up) and decreased significantly (P<.001) in drug therapy patients (mean [SD] of 59.7% [11.8%] at baseline to 48.8% [7.9%] at final follow-up). CONCLUSION: Among patients with recent MI, silent myocardial ischemia verified by stress imaging, and 1- or 2-vessel coronary artery disease, PCI compared with anti-ischemic drug therapy reduced the long-term risk of major cardiac events. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00387231.
Resumo:
BACKGROUND: In humans, it is not known whether physical endurance exercise training promotes coronary collateral growth. The following hypotheses were tested: the expected collateral flow reduction after percutaneous coronary intervention of a stenotic lesion is prevented by endurance exercise training; collateral flow supplied to an angiographically normal coronary artery improves in response to exercise training; there is a direct relationship between the change of fitness after training and the coronary collateral flow change. METHODS AND RESULTS: Forty patients (age 61+/-8 years) underwent a 3-month endurance exercise training program with baseline and follow-up assessments of coronary collateral flow. Patients were divided into an exercise training group (n=24) and a sedentary group (n=16) according to the fact whether they adhered or not to the prescribed exercise program, and whether or not they showed increased endurance (VO2max in ml/min per kg) and performance (W/kg) during follow-up versus baseline bicycle spiroergometry. Collateral flow index (no unit) was obtained using pressure sensor guidewires positioned in the coronary artery undergoing percutaneous coronary intervention and in a normal vessel. In the vessel initially undergoing percutaneous coronary intervention, there was an increase in collateral flow index among exercising but not sedentary patients from 0.155+/-0.081 to 0.204+/-0.056 (P=0.03) and from 0.189+/-0.084 to 0.212+/-0.077 (NS), respectively. In the normal vessel, collateral flow index changes were from 0.176+/-0.075 to 0.227+/-0.070 in the exercise group (P=0.0002), and from 0.219+/-0.103 to 0.238+/-0.086 in the sedentary group (NS). A direct correlation existed between the change in collateral flow index from baseline to follow-up and the respective alteration of VO2max (P=0.007) and Watt (P=0.03). CONCLUSION: A 3-month endurance exercise training program augments coronary collateral supply to normal vessels, and even to previously stenotic arteries having undergone percutaneous coronary intervention before initiating the program. There appears to be a dose-response relation between coronary collateral flow augmentation and exercise capacity gained.
Resumo:
INTRODUCTION: Nebivolol, a highly selective beta1-adrenergic receptor-blocker, increases basal and stimulated endothelial nitric oxide (NO)-release. It is unknown, whether coronary perfusion is improved by the increase in NO availability. Therefore, we sought to evaluate the effect of nebivolol on coronary flow reserve (CFR) and collateral flow. METHODS: Doppler-flow wire derived coronary flow velocity measurements were obtained in ten controls and eight patients with coronary artery disease (CAD) at rest and after intracoronary nebivolol. CFR was defined as maximal flow during adenosine-induced hyperemia divided by resting flow. In the CAD group, collateral flow was determined after dilatation of a flow-limiting coronary stenosis. Collateral flow index (CFI) was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS: CFR at rest was 3.0+/-0.6 in controls and 2.1+/-0.4 in CAD patients. After intracoronary doses of 0.1, 0.25, and 0.5 mg nebivolol, CFR increased to 3.4+/-0.7, 3.9+/-0.9, and 4.0+/-0.1 (p<0.01) in controls, and to 2.3+/-0.7, 2.6+/-0.9, and 2.6+/-0.5 (p<0.05) in CAD patients. CFI decreased significantly with intracoronary nebivolol and correlated to changes in heart rate (r=0.75, p<0.001) and rate-pressure product (r=0.59, p=0.001). DISCUSSION: Intracoronary nebivolol is associated with a significant increase in CFR due to reduction in resting flow (controls), or due to an increase in maximal coronary flow (CAD patients). CFI decreased with nebivolol parallel to the reduction in myocardial oxygen consumption.
Resumo:
BACKGROUND: Paclitaxel-eluting stents (PES) have been shown to reduce the rate of restenosis and the need for repeated revascularization procedures compared with bare metal stents. However, long-term effects of paclitaxel on vascular function are unknown. The purpose of the present study was to assess coronary vasomotor response to exercise after paclitaxel-eluting stent implantation. METHODS: Coronary vasomotion was evaluated by biplane quantitative coronary angiography at rest and during supine bicycle exercise in 27 patients with coronary artery disease. Twelve patients were treated with a bare metal stent (controls), and fifteen patients with a paclitaxel-eluting stent. All patients were restudied 6+/-2 (range 2-12) months after stent implantation. Minimal luminal diameter, stent diameter, proximal, distal and a reference vessel diameter were determined. RESULTS: Reference vessels showed exercise-induced vasodilation in both groups (+20+/-5% controls; +26+/-3% PES group). Vasomotion within the stented vessel segments was abolished. In the controls, the adjacent segments proximal and distal to the stent showed exercise-induced vasodilation (+17+/-3% and +24+/-4%). In contrast, there was exercise-induced vasoconstriction of the proximal and distal vessel segments adjacent to the paclitaxel-eluting stent (-13+/-6% and -18+/-4%; p<0.005). After sublingual nitroglycerin, the proximal and distal vessel segments dilated in both groups. Exercise-induced vasoconstriction adjacent to paclitaxel-eluting stent correlated inversely with the time interval after stent implantation. CONCLUSIONS: Paclitaxel-eluting stent implantation is associated with exercise-induced vasoconstriction in the persistent region suggesting endothelial dysfunction as the underlying mechanism. Improvement of vascular function occurs over time, indicating delayed vascular healing.
Resumo:
AIMS: We investigated whether myeloid-related protein 8/14 complex (MRP8/14) expressed by infiltrating monocytes and granulocytes may represent a mediator and early biomarker of acute coronary syndromes (ACS). METHODS AND RESULTS: Immunohistochemistry of coronary thrombi was done in 41 ACS patients. Subsequently, levels of MRP8/14 were assessed systemically in 75 patients with ACS and culprit lesions, with stable coronary artery disease (CAD), or with normal coronary arteries. In a subset of patients, MRP8/14 was measured systemically and at the site of coronary occlusion. Macrophages and granulocytes, but not platelets stained positive for MRP8/14 in 76% of 41 thrombi patients. In ACS, local MRP8/14 levels [22.0 (16.2-41.5) mg/L] were increased when compared with systemic levels [13.4 (8.1-14.7) mg/L, P = 0.03]. Systemic levels of MRP8/14 were markedly elevated [15.1 (12.1-21.8) mg/L, P = 0.001] in ACS when compared with stable CAD [4.6 (3.5-7.1) mg/L] or normals [4.8 (4.0-6.3) mg/L]. Using a cut-off level of 8 mg/L, MRP8/14 but not myoglobin or troponin, identified ACS presenting within 3 h from symptom onset. CONCLUSION: In ACS, MRP8/14 is markedly expressed at the site of coronary occlusion by invading phagocytes. The occurrence of elevated MRP8/14 in the systemic circulation prior to markers of myocardial necrosis makes it a prime candidate for the detection of unstable plaques and management of ACS.
Resumo:
Although rare, stent thrombosis remains a severe complication after stent implantation owing to its high morbidity and mortality. Since the introduction of drug-eluting stents (DES), most interventional centers have noted stent thrombosis up to 3 years after implantation, a complication rarely seen with bare-metal stents. Some data from large registries and meta-analyses of randomized trials indicate a higher risk for DES thrombosis, whereas others suggest an absence of such a risk. Several factors are associated with an increased risk of stent thrombosis, including the procedure itself (stent malapposition and/or underexpansion, number of implanted stents, stent length, persistent slow coronary blood flow, and dissections), patient and lesion characteristics, stent design, and premature cessation of antiplatelet drugs. Drugs released from DES exert distinct biological effects, such as activation of signal transduction pathways and inhibition of cell proliferation. As a result, although primarily aimed at preventing vascular smooth muscle cell proliferation and migration (ie, key factors in the development of restenosis), they also impair reendothelialization, which leads to delayed arterial healing, and induce tissue factor expression, which results in a prothrombogenic environment. In the same way, polymers used to load these drugs have been associated with DES thrombosis. Finally, DES impair endothelial function of the coronary artery distal to the stent, which potentially promotes the risk of ischemia and coronary occlusion. Although several reports raise the possibility of a substantially higher risk of stent thrombosis in DES, evidence remains inconclusive; as a consequence, both large-scale and long-term clinical trials, as well as further mechanistic studies, are needed. The present review focuses on the pathophysiological mechanisms and pathological findings of stent thrombosis in DES.