256 resultados para Magnetic resonance imaging, perfusion-weighted


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proton magnetic resonance spectroscopy (MRS) allows the assessment of various cerebral metabolites non-invasively in vivo. Among 1H MRS-detectable metabolites, N-acetyl-aspartate and N-acetyl-aspartyl-glutamate (tNAA), trimethylamines (TMA), creatine and creatine phosphate (tCr), inositol (Ins) and glutamate (Gla) are of particular interest, since these moieties can be assigned to specific neuronal and glial metabolic pathways, membrane constituents, and energy metabolism. In this study on 94 subjects from a memory clinic population, 1H MRS results (single voxel STEAM: TE 20 ms, TR 1500 ms) on the above metabolites were assessed for five different brain regions in probable vascular dementia (VD), probable Alzheimer's disease (AD), and age-matched healthy controls. In both VD and AD, ratios of tNAA/tCr were decreased, which may be attributed to neuronal atrophy and loss, and Ins/tCr-ratios were increased indicating either enhanced gliosis or alteration of the cerebral inositol metabolism. However, the topographical distribution of the metabolic alterations in both diseases differed, revealing a temporoparietal pattern for AD and a global, subcortically pronounced pattern for VD. Furthermore, patients suffering from vascular dementia (VD) had remarkably enhanced TMA/tCr ratios, potentially due to ongoing degradation of myelin. Thus, the metabolic alterations obtained by 1H MRS in vivo allow insights into the pathophysiology of the different dementias and may be useful for diagnostic classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The transdisciplinary research project Virtopsy is dedicated to implementing modern imaging techniques into forensic medicine and pathology in order to augment current examination techniques or even to offer alternative methods. Our project relies on three pillars: three-dimensional (3D) surface scanning for the documentation of body surfaces, and both multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) to visualise the internal body. Three-dimensional surface scanning has delivered remarkable results in the past in the 3D documentation of patterned injuries and of objects of forensic interest as well as whole crime scenes. Imaging of the interior of corpses is performed using MSCT and/or MRI. MRI, in addition, is also well suited to the examination of surviving victims of assault, especially choking, and helps visualise internal injuries not seen at external examination of the victim. Apart from the accuracy and three-dimensionality that conventional documentations lack, these techniques allow for the re-examination of the corpse and the crime scene even decades later, after burial of the corpse and liberation of the crime scene. We believe that this virtual, non-invasive or minimally invasive approach will improve forensic medicine in the near future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem decomposition of brain tissue was investigated by (1)H-magnetic resonance spectroscopy (MRS) in a sheep head model and selected human cases. Aiming at the eventual estimation of postmortem intervals in forensic medicine, this study focuses on the characterization and identification of newly observed metabolites. In situ single-voxel (1)H-MRS at 1.5 T was complemented by multidimensional homo- and heteronuclear high-resolution NMR spectroscopy of an extract of sheep brain tissue. The inclusion of spectra of model solutions in the program LC Model confirmed the assignments in situ. The first postmortem phase was characterized mainly by changes in the concentrations of metabolites usually observed in vivo and by the appearance of previously reported decay products. About 3 days postmortem, new metabolites, including free trimethylammonium, propionate, butyrate, and iso-butyrate, started to appear in situ. Since the observed metabolites and the time course is comparable in sheep and human brain tissue, the model system seems to be appropriate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

MR imaging at 1.5T is considered the prime cross-sectional imaging modality for characterization of adrenal lesions. This is of utmost clinical importance, because non-functioning adenoma and adrenal metastasis are fairly common. The differentiation of these two tumor entities primarily is based on chemical shift imaging, also known as dual echo in-phase and opposed-phase imaging. At 3.0 T, the echo time pairs for in-phase and opposed-phase MR imaging need to be adjusted because the frequency difference is double that of standard 1.5T MR systems. Unfortunately, the acquisition of the first opposed-phase echo at 1.1 milliseconds and the first in-phase echo at 2.2 milliseconds within the same breath-hold requires unacceptably high receiver bandwidths at 3.0 T. Therefore, alternative data collection schemes have been implemented. This article reviews the current literature regarding adrenal imaging at 3.0 T with a focus on the chemical shift technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: During recent years, (chemo)radiotherapy has evolved into a primary treatment modality for both early and advanced laryngeal and hypopharyngeal carcinomas. Head and neck surgeons will be concerned more frequently with patients presenting symptoms and signs suggesting recurrent tumor or complications of (chemo)radiotherapy. RECENT FINDINGS: Analysis of histologic characteristics and tumor spread of recurrent carcinomas on whole-organ slices of salvage laryngectomy specimens showed that recurrent laryngeal carcinomas are often present with multiple tumor foci dispersed in different regions; furthermore, they may develop beneath an intact mucosa. Only a few articles analyze the reliability of laryngoscopy and biopsy in detecting recurrences after (chemo)radiotherapy: the number of false negative biopsies is relatively high. The differentiation between radionecrosis and tumor recurrence is difficult by computed tomography scan and magnetic resonance imaging in many cases. Positron emission tomography-computed tomography and diffusion-weighted magnetic resonance imaging are promising diagnostic modalities to detect or exclude persistent or recurrent disease after (chemo)radiotherapy. SUMMARY: Endoscopy with biopsy, computed tomography scan and conventional magnetic resonance imaging present several deficiencies in diagnosing recurrent disease after (chemo)radiotherapy. New imaging modalities such as positron emission tomography-computed tomography and diffusion-weighted magnetic resonance imaging show promising results, increasing the diagnostic efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem examination of chest trauma is an important domain in forensic medicine, which is today performed using autopsy. Since the implementation of cross-sectional imaging methods in forensic medicine such as computed tomography (CT) and magnetic resonance imaging (MRI), a number of advantages in comparison with autopsy have been described. Within the scope of validation of cross-sectional radiology in forensic medicine, the comparison of findings of postmortem imaging and autopsy in chest trauma was performed. METHODS: This retrospective study includes 24 cases with chest trauma that underwent postmortem CT, MRI, and autopsy. Two board-certified radiologists, blind to the autopsy findings, evaluated the radiologic data independently. Each radiologist interpreted postmortem CT and MRI data together for every case. The comparison of the results of the radiologic assessment with the autopsy and a calculation of interobserver discrepancy was performed. RESULTS: Using combined CT and MRI, between 75% and 100% of the investigated findings, except for hemomediastinum (70%), diaphragmatic ruptures (50%; n=2) and heart injury (38%), were discovered. Although the sensitivity and specificity regarding pneumomediastinum, pneumopericardium, and pericardial effusion were not calculated, as these findings were not mentioned at the autopsy, these findings were clearly seen radiologically. The averaged interobserver concordance was 90%. CONCLUSION: The sensitivity and specificity of our results demonstrate that postmortem CT and MRI are useful diagnostic methods for assessing chest trauma in forensic medicine as a supplement to autopsy. Further radiologic-pathologic case studies are necessary to define the role of postmortem CT and MRI as a single examination modality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess magnetic resonance (MR)-colonography (MRC) for detection of colorectal lesions using two different T1w three-dimensional (3D)-gradient-recalled echo (GRE)-sequences and integrated parallel data acquisition (iPAT) at a 3.0 Tesla MR-unit. MATERIALS AND METHODS: In this prospective study, 34 symptomatic patients underwent dark lumen MRC at a 3.0 Tesla unit before conventional colonoscopy (CC). After colon distension with tap water, 2 high-resolution T1w 3D-GRE [3-dimensional fast low angle shot (3D-FLASH), iPAT factor 2 and 3D-volumetric interpolated breathhold examination (VIBE), iPAT 3] sequences were acquired without and after bolus injection of gadolinium. Prospective evaluation of MRC was performed. Image quality of the different sequences was assessed qualitatively and quantitatively. The findings of the same day CC served as standard of reference. RESULTS: MRC identified all polyps >5 mm (16 of 16) in size and all carcinomas (4 of 4) correctly. Fifty percent of the small polyps 0.6). CONCLUSIONS: MRC using 3D-GRE-sequences and iPAT is feasible at 3.0 T-systems. The high-resolution 3D-FLASH was slightly preferred over the 3D-VIBE because of better image quality, although both used sequences showed no statistical significant difference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteoarthritis is thought to be caused by a combination of intrinsic vulnerabilities of the joint, such as anatomic shape and alignment, and environmental factors, such as body weight, injury, and overuse. It has been postulated that much of osteoarthritis is due to anatomic deformities. Advances in surgical techniques such as the periacetabular osteotomy, safe surgical dislocation of the hip, and hip arthroscopy have provided us with effective and safe tools to correct these anatomical problems. The limiting factor in treatment outcome in many mechanically compromised hips is the degree of cartilage damage which has occurred prior to treatment. In this regard, the role of imaging, utilizing plain radiographs in conjunction with magnetic resonance imaging, is becoming vitally important for the detection of these anatomic deformities and pre-radiographic arthritis. In this article, we will outline the plain radiographic features of hip deformities that can cause instability or impingement. Additionally, we will illustrate the use of MRI imaging to detect subtle anatomic abnormalities, as well as the use of biochemical imaging techniques such as dGEMRIC to guide clinical decision making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to evaluate the feasibility and reproducibility of high-resolution magnetic resonance imaging (MRI) and quantitative T2 mapping of the talocrural cartilage within a clinically applicable scan time using a new dedicated ankle coil and high-field MRI. MATERIALS AND METHODS: Ten healthy volunteers (mean age 32.4 years) underwent MRI of the ankle. As morphological sequences, proton density fat-suppressed turbo spin echo (PD-FS-TSE), as a reference, was compared with 3D true fast imaging with steady-state precession (TrueFISP). Furthermore, biochemical quantitative T2 imaging was prepared using a multi-echo spin-echo T2 approach. Data analysis was performed three times each by three different observers on sagittal slices, planned on the isotropic 3D-TrueFISP; as a morphological parameter, cartilage thickness was assessed and for T2 relaxation times, region-of-interest (ROI) evaluation was done. Reproducibility was determined as a coefficient of variation (CV) for each volunteer; averaged as root mean square (RMSA) given as a percentage; statistical evaluation was done using analysis of variance. RESULTS: Cartilage thickness of the talocrural joint showed significantly higher values for the 3D-TrueFISP (ranging from 1.07 to 1.14 mm) compared with the PD-FS-TSE (ranging from 0.74 to 0.99 mm); however, both morphological sequences showed comparable good results with RMSA of 7.1 to 8.5%. Regarding quantitative T2 mapping, measurements showed T2 relaxation times of about 54 ms with an excellent reproducibility (RMSA) ranging from 3.2 to 4.7%. CONCLUSION: In our study the assessment of cartilage thickness and T2 relaxation times could be performed with high reproducibility in a clinically realizable scan time, demonstrating new possibilities for further investigations into patient groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-parametric and quantitative magnetic resonance imaging (MRI) techniques have come into the focus of interest, both as a research and diagnostic modality for the evaluation of patients suffering from mild cognitive decline and overt dementia. In this study we address the question, if disease related quantitative magnetization transfer effects (qMT) within the intra- and extracellular matrices of the hippocampus may aid in the differentiation between clinically diagnosed patients with Alzheimer disease (AD), patients with mild cognitive impairment (MCI) and healthy controls. We evaluated 22 patients with AD (n=12) and MCI (n=10) and 22 healthy elderly (n=12) and younger (n=10) controls with multi-parametric MRI. Neuropsychological testing was performed in patients and elderly controls (n=34). In order to quantify the qMT effects, the absorption spectrum was sampled at relevant off-resonance frequencies. The qMT-parameters were calculated according to a two-pool spin-bath model including the T1- and T2 relaxation parameters of the free pool, determined in separate experiments. Histograms (fixed bin-size) of the normalized qMT-parameter values (z-scores) within the anterior and posterior hippocampus (hippocampal head and body) were subjected to a fuzzy-c-means classification algorithm with downstreamed PCA projection. The within-cluster sums of point-to-centroid distances were used to examine the effects of qMT- and diffusion anisotropy parameters on the discrimination of healthy volunteers, patients with Alzheimer and MCIs. The qMT-parameters T2(r) (T2 of the restricted pool) and F (fractional pool size) differentiated between the three groups (control, MCI and AD) in the anterior hippocampus. In our cohort, the MT ratio, as proposed in previous reports, did not differentiate between MCI and AD or healthy controls and MCI, but between healthy controls and AD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In general, vascular contributions to the in vivo magnetic resonance (MR) brain spectrum are too small to be relevant. In cerebral uptake studies, however, vascular contributions may constitute a major confounder. MR visibility of vascular Phe was investigated by recording localized spectra from fully oxygenated and well-mixed whole blood. Blood Phe levels determined by MR spectroscopy (MRS) and ion-exchange chromatography showed excellent correlation. In addition, effects of blood flow were shown to have a small effect on signal amplitude with the MRS methodology used. Hence, blood Phe is almost completely MR visible at 1.5 T, even though it is severely broadened at higher fields. Without appropriate correction, cerebral Phe influx in studies of brain Phe uptake in phenylketonuria patients or healthy subjects would appear to be faster and lead to higher levels. Similar effects are envisaged for studies of ethanol or glucose uptake across the blood-brain barrier.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In spite of the facts that magnetic resonance spectroscopy (MRS) is applied as clinical tool in non-specialized institutions and that semi-automatic acquisition and processing tools can be used to produce quantitative information from MRS exams without expert information, issues of spectral quality and quality assessment are neglected in the literature of MR spectroscopy. Even worse, there is no consensus among experts on concepts or detailed criteria of quality assessment for MR spectra. Furthermore, artifacts are not at all conspicuous in MRS and can easily be taken for true, interpretable features. This article aims to increase interest in issues of spectral quality and quality assessment, to start a larger debate on generally accepted criteria that spectra must fulfil to be clinically and scientifically acceptable, and to provide a sample gallery of artifacts, which can be used to raise awareness for potential pitfalls in MRS.