208 resultados para Hip Prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limited data exist on the efficacy of long-term therapies for osteoporosis. In osteoporotic postmenopausal women receiving denosumab for 7 years, nonvertebral fracture rates significantly decreased in years 4-7 versus years 1-3. This is the first demonstration of a further benefit on fracture outcomes with long-term therapy for osteoporosis. INTRODUCTION This study aimed to evaluate whether denosumab treatment continued beyond 3 years is associated with a further reduction in nonvertebral fracture rates. METHODS Participants who completed the 3-year placebo-controlled Fracture REduction Evaluation of Denosumab in Osteoporosis every 6 Months (FREEDOM) study were invited to participate in an open-label extension. The present analysis includes 4,074 postmenopausal women with osteoporosis (n = 2,343 long-term; n = 1,731 cross-over) who enrolled in the extension, missed ≤1 dose during their first 3 years of denosumab treatment, and continued into the fourth year of treatment. Comparison of nonvertebral fracture rates during years 1-3 of denosumab with that of the fourth year and with the rate during years 4-7 was evaluated. RESULTS For the combined group, the nonvertebral fracture rate per 100 participant-years was 2.15 for the first 3 years of denosumab treatment (referent) and 1.36 in the fourth year (rate ratio [RR] = 0.64; 95 % confidence interval (CI) = 0.48 to 0.85, p = 0.003). Comparable findings were observed in the groups separately and when nonvertebral fracture rates during years 1-3 were compared to years 4-7 in the long-term group (RR = 0.79; 95 % CI = 0.62 to 1.00, p = 0.046). Fracture rate reductions in year 4 were most prominent in subjects with persisting low hip bone mineral density (BMD). CONCLUSIONS Denosumab treatment beyond 3 years was associated with a further reduction in nonvertebral fracture rate that persisted through 7 years of continuous denosumab administration. The degree to which denosumab further reduces nonvertebral fracture risk appears influenced by the hip bone density achieved with initial therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the issue of fully automatic segmentation of a hip CT image with the goal to preserve the joint structure for clinical applications in hip disease diagnosis and treatment. For this purpose, we propose a Multi-Atlas Segmentation Constrained Graph (MASCG) method. The MASCG method uses multi-atlas based mesh fusion results to initialize a bone sheetness based multi-label graph cut for an accurate hip CT segmentation which has the inherent advantage of automatic separation of the pelvic region from the bilateral proximal femoral regions. We then introduce a graph cut constrained graph search algorithm to further improve the segmentation accuracy around the bilateral hip joint regions. Taking manual segmentation as the ground truth, we evaluated the present approach on 30 hip CT images (60 hips) with a 15-fold cross validation. When the present approach was compared to manual segmentation, an average surface distance error of 0.30 mm, 0.29 mm, and 0.30 mm was found for the pelvis, the left proximal femur, and the right proximal femur, respectively. A further look at the bilateral hip joint regions demonstrated an average surface distance error of 0.16 mm, 0.21 mm and 0.20 mm for the acetabulum, the left femoral head, and the right femoral head, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hip dysplasia is characterized by insufficient femoral head coverage (FHC). Quantification of FHC is of importance as the underlying goal of the surgery to treat hip dysplasia is to restore a normal acetabular morphology and thereby to improve FHC. Unlike a pure 2D X-ray radiograph-based measurement method or a pure 3D CT-based measurement method, previously we presented a 2.5D method to quantify FHC from a single anteriorposterior (AP) pelvic radiograph. In this study, we first quantified and compared 3D FHC between a normal control group and a patient group using a CT-based measurement method. Taking the CT-based 3D measurements of FHC as the gold standard, we further quantified the bias, precision and correlation between the 2.5D measurements and the 3D measurements on both the control group and the patient group. Based on digitally reconstructed radiographs (DRRs), we investigated the influence of the pelvic tilt on the 2.5D measurements of FHC. The intraclass correlation coefficients (ICCs) for absolute agreement was used to quantify interobserver reliability and intraobserver reproducibility of the 2.5D measurement technique. The Pearson correlation coefficient, r, was used to determine the strength of the linear association between the 2.5D and the 3D measurements. Student's t-test was used to determine whether the differences between different measurements were statistically significant. Our experimental results demonstrated that both the interobserver reliability and the intraobserver reproducibility of the 2.5D measurement technique were very good (ICCs > 0.8). Regression analysis indicated that the correlation was very strong between the 2.5D and the 3D measurements (r = 0.89, p < 0.001). Student's t-test showed that there were no statistically significant differences between the 2.5D and the 3D measurements of FHC on the patient group (p > 0.05). The results of this study provided convincing evidence demonstrating the validity of the 2.5D measurements of FHC from a single AP pelvic radiograph and proved that it could serve as a surrogate for 3D CT-based measurements. Thus it may be possible to use this method to avoid a CT scan for the purpose of estimating 3D FHC in diagnosis and post-operative treatment evaluation of patients with hip dysplasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. MATERIALS AND METHODS Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. RESULTS A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. CONCLUSIONS The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pelvic discontinuity is a complex problem in revision total hip arthroplasty. Although rare, the incidence is likely to increase due to the ageing population and the increasing number of total hip arthroplasties being performed. The various surgical options available to solve this problem include plating, massive allografts, reconstruction rings, custom triflanged components and tantalum implants. However, the optimal solution remains controversial. None of the known methods completely solves the major obstacles associated with this problem, such as restoration of massive bone loss, implant failure in the short- and long-term and high complication rates. This review discusses the diagnosis, decision making, and treatment options of pelvic discontinuity in revision total hip arthroplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To identify the influence of fixed prosthesis type on biologic and technical complication rates in the context of screw versus cement retention. Furthermore, a multivariate analysis was conducted to determine which factors, when considered together, influence the complication and failure rates of fixed implant-supported prostheses. MATERIALS AND METHODS Electronic searches of MEDLINE (PubMed), EMBASE, and the Cochrane Library were conducted. Selected inclusion and exclusion criteria were used to limit the search. Data were analyzed statistically with simple and multivariate random-effects Poisson regressions. RESULTS Seventy-three articles qualified for inclusion in the study. Screw-retained prostheses showed a tendency toward and significantly more technical complications than cemented prostheses with single crowns and fixed partial prostheses, respectively. Resin chipping and ceramic veneer chipping had high mean event rates, at 10.04 and 8.95 per 100 years, respectively, for full-arch screwed prostheses. For "all fixed prostheses" (prosthesis type not reported or not known), significantly fewer biologic and technical complications were seen with screw retention. Multivariate analysis revealed a significantly greater incidence of technical complications with cemented prostheses. Full-arch prostheses, cantilevered prostheses, and "all fixed prostheses" had significantly higher complication rates than single crowns. A significantly greater incidence of technical and biologic complications was seen with cemented prostheses. CONCLUSION Screw-retained fixed partial prostheses demonstrated a significantly higher rate of technical complications and screw-retained full-arch prostheses demonstrated a notably high rate of veneer chipping. When "all fixed prostheses" were considered, significantly higher rates of technical and biologic complications were seen for cement-retained prostheses. Multivariate Poisson regression analysis failed to show a significant difference between screw- and cement-retained prostheses with respect to the incidence of failure but demonstrated a higher rate of technical and biologic complications for cement-retained prostheses. The incidence of technical complications was more dependent upon prosthesis and retention type than prosthesis or abutment material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periazetabuläre Frakturen bei Hüftprothesen nehmen aufgrund der Überalterung und der zunehmenden Aktivität alter Menschen zu. Die periprothetischen Azetabulumfrakturen werden anhand der Einteilung von Letournel klassifiziert. Wenn beide Azetabulumpfeiler bei Hüftprothese betroffen sind, wird auch von einer Beckendiskontinuität gesprochen. Durch eine laterale Kompression können auch periazetabuläre Schambeinastfrakturen und/oder transiliakale Frakturen auftreten. Für die Therapieentscheidung (konservativ, alleinige Osteosynthese, Revisionshüfttotalprothese mit oder ohne zusätzliche Osteosynthese des Vorder- und/oder Hinterpfeilers) und die Zugangswahl bei operativer Versorgung werden patientenspezifische (Alter, Morbidität, Osteoporose, Aktivitätslevel des Patienten), frakturspezifische (Frakturtyp, Dislokationsausmaß, Impression des Doms oder der Hinterwand) und auch prothesenspezifische Faktoren (Art der implantierten Prothese [Hemiprothese vs. Totalprothese], Pfannenstabilität, Zeichen eines Prothesenabriebs, Ausmaß und Lokalisation einer azetabulären Lyse, Stabilität und Lysezeichen des Prothesenschafts) berücksichtigt. Bei akuten Beckendiskontinuitäten werden neben einer Osteosynthese des dorsalen Pfeilers zunehmend eine schnell ossär integrierbare Pfanne (Tantalum [„Trabecular Metal“: TM]) mit oder ohne Augment und/oder Allograft und allenfalls in einer sog. „Cup-Cage“-Technik (TM-Pfanne mit einem abstützenden Revisionsring [Burch-Schneider-Ring] analog zur Therapie von chronischen Beckendiskontinuitäten empfohlen. Bei großen Lysezonen und starken Dislokationen des vorderen Pfeilers und der quadrilateralen Fläche können intrapelvine Zugänge (modifizierter Stoppa- oder Pararectus-Zugang nach Keel) zur zusätzlichen Zuggurtungsosteosynthese des vorderen Pfeilers und Abstützung der quadrilateralen Fläche gewählt werden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Non-steroidal anti-inflammatory drugs (NSAIDs) are the backbone of osteoarthritis pain management. We aimed to assess the effectiveness of different preparations and doses of NSAIDs on osteoarthritis pain in a network meta-analysis. METHODS For this network meta-analysis, we considered randomised trials comparing any of the following interventions: NSAIDs, paracetamol, or placebo, for the treatment of osteoarthritis pain. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) and the reference lists of relevant articles for trials published between Jan 1, 1980, and Feb 24, 2015, with at least 100 patients per group. The prespecified primary and secondary outcomes were pain and physical function, and were extracted in duplicate for up to seven timepoints after the start of treatment. We used an extension of multivariable Bayesian random effects models for mixed multiple treatment comparisons with a random effect at the level of trials. For the primary analysis, a random walk of first order was used to account for multiple follow-up outcome data within a trial. Preparations that used different total daily dose were considered separately in the analysis. To assess a potential dose-response relation, we used preparation-specific covariates assuming linearity on log relative dose. FINDINGS We identified 8973 manuscripts from our search, of which 74 randomised trials with a total of 58 556 patients were included in this analysis. 23 nodes concerning seven different NSAIDs or paracetamol with specific daily dose of administration or placebo were considered. All preparations, irrespective of dose, improved point estimates of pain symptoms when compared with placebo. For six interventions (diclofenac 150 mg/day, etoricoxib 30 mg/day, 60 mg/day, and 90 mg/day, and rofecoxib 25 mg/day and 50 mg/day), the probability that the difference to placebo is at or below a prespecified minimum clinically important effect for pain reduction (effect size [ES] -0·37) was at least 95%. Among maximally approved daily doses, diclofenac 150 mg/day (ES -0·57, 95% credibility interval [CrI] -0·69 to -0·46) and etoricoxib 60 mg/day (ES -0·58, -0·73 to -0·43) had the highest probability to be the best intervention, both with 100% probability to reach the minimum clinically important difference. Treatment effects increased as drug dose increased, but corresponding tests for a linear dose effect were significant only for celecoxib (p=0·030), diclofenac (p=0·031), and naproxen (p=0·026). We found no evidence that treatment effects varied over the duration of treatment. Model fit was good, and between-trial heterogeneity and inconsistency were low in all analyses. All trials were deemed to have a low risk of bias for blinding of patients. Effect estimates did not change in sensitivity analyses with two additional statistical models and accounting for methodological quality criteria in meta-regression analysis. INTERPRETATION On the basis of the available data, we see no role for single-agent paracetamol for the treatment of patients with osteoarthritis irrespective of dose. We provide sound evidence that diclofenac 150 mg/day is the most effective NSAID available at present, in terms of improving both pain and function. Nevertheless, in view of the safety profile of these drugs, physicians need to consider our results together with all known safety information when selecting the preparation and dose for individual patients. FUNDING Swiss National Science Foundation (grant number 405340-104762) and Arco Foundation, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Patients after primary hip or knee replacement surgery can benefit from postoperative treatment in terms of improvement of independence in ambulation, transfers, range of motion and muscle strength. After discharge from hospital, patients are referred to different treatment destination and modalities: intensive inpatient rehabilitation (IR), cure (medically prescribed stay at a convalescence center), or ambulatory treatment (AT) at home. The purpose of this study was to 1) measure functional health (primary outcome) and function relevant factors in patients with hip or knee arthroplasty and to compare them in relation to three postoperative management strategies: AT, Cure and IR and 2) compare the post-operative changes in patient's health status (between preoperative and the 6 month follow-up) for three rehabilitation settings. METHODS Natural observational, prospective two-center study with follow-up. Sociodemographic data and functional mobility tests, Timed Up and Go (TUG) and Iowa Level of Assistance Scale (ILOAS) of 201 patients were analysed before arthroplasty and at the end of acute hospital stay (mean duration of stay: 9.7 days +/- 3.9). Changes in health state were measured with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) before and 6 months after arthroplasty. RESULTS Compared to patients referred for IR and Cure, patients referred for AT were significantly younger and less comorbid. Patients admitted to IR had the highest functional disability before arthroplasty. Before rehabilitation, mean TUG was 40.0 s in the IR group, 33.9 s in the Cure group, and 27.5 s in the AT group, and corresponding mean ILOAS was 16.0, 13.0 and 12.2 (50.0 = worst). At the 6 months follow-up, the corresponding effect sizes of the WOMAC global score were 1.32, 1.87, and 1.51 (>0 means improvement). CONCLUSIONS Age, comorbidity and functional disability are associated with referral for intensive inpatient rehabilitation after hip or knee arthroplasty and partly affect health changes after rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To assess whether reaction time (RT) and movement time (MT), as the two components of the total brake response time (TBRT) and brake force (BF) are different in patients with a foot joint arthrodesis in comparison to controls. METHODS The study was a comparative case series in a driving simulator under realistic driving conditions. Mobile patients without a walker, ≥6 months after surgery who were driving a car and had no neurological co-morbidity, knee or hip joint prosthesis were included in the study. The selection criteria resulted in 12 patients with right tibiotalar joint arthrodesis (TTJA) and 12 patients with another right foot joint arthrodesis (OFJA), who were compared to 17 individuals without any ankle-joint pathology. For TBRT, an empirical safe driving threshold of 700 ms was used. The outcome measures were RT, MT, TBRT, BF and McGuire score. RESULTS MT (p = 0.034) and TBRT (p = 0.026) were longer in TTJA patients in comparison with the controls. Also, more patients with TTJA than patients with OFJA and controls exceeded the safe driving threshold (p = 0.028). The outcomes in OFJA patients and in controls were comparable. The McGuire score was similar between the TTJA and OFJA patients (p = 0.26). CONCLUSIONS Significantly slower MT and TBRT, and significantly more patients exceeding the safe driving threshold, were observed after a tibiotalar-joint arthrodesis in comparison to the controls. Patients with OFJAs were not significantly different from the controls. Driving and emergency braking may be impaired after tibiotalar-joint arthrodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.