285 resultados para Coronary Artery Disease
Resumo:
AIMS Cystatin C is a well established marker of kidney function. There is evidence that cystatin C concentrations are also associated with mortality. The present analysis prospectively evaluated the associations of cystatin C with all-cause and cardiovascular (CV) mortality in a well-characterized cohort of persons undergoing angiography, but without overt renal insufficiency. METHODS Cystatin C was available in 2998 persons (mean age: 62.7 ± 10.5 years; 30.3% women). Of those 2346 suffered from coronary artery disease (CAD) and 652 (controls) did not. Creatinine (mean ± SD: 83.1 ± 47.8 vs. 74.1 ± 24.7 μmol/L, p = 0.036) but not Cystatin C (mean ± SD: 1.02 ± 0.44 vs. 0.92 ± 0.26 mg/L, p = 0.065) was significantly higher in patients with CAD. After a median follow-up of 9.9 years, in total 898 (30%) deaths occurred, 554 (18.5%) due to CV disease and 326 (10.9%) due to non-CV causes. Multivariable-adjusted Cox analysis (adjusting for eGFR and established cardiovascular risk factors, lipid lowering therapy, angiographic coronary artery disease, and C-reactive protein) revealed that patients in the highest cystatin C quartile were at an increased risk for all-cause (hazard ratio (HR) 1.93, 95% CI 1.50-2.48) and CV mortality (HR 2.05 95% CI 1.48-2.84) compared to those in the lowest quartile. The addition of cystatin C to a model consisting of established cardiovascular risk factors increased the area under the receiver-operating characteristic curve for CV and all-cause mortality, but the difference was statistically not significant. However, reclassification analysis revealed significant improvement by addition of cystatin C for CV and all-cause mortality (p < 0.001), respectively. CONCLUSION The concentration of cystatin C is strongly associated with long-term all-cause and cardiovascular mortality in patients referred to coronary angiography, irrespective of creatinine-based renal function.
Resumo:
BACKGROUND Patients with prior coronary artery bypass graft surgery (CABG) who present with an acute coronary syndrome have a high risk for recurrent events. Whether intensive antiplatelet therapy with ticagrelor might be beneficial compared with clopidogrel is unknown. In this substudy of the PLATO trial, we studied the effects of randomized treatment dependent on history of CABG. METHODS Patients participating in PLATO were classified according to whether they had undergone prior CABG. The trial's primary and secondary end points were compared using Cox proportional hazards regression. RESULTS Of the 18,613 study patients, 1,133 (6.1%) had prior CABG. Prior-CABG patients had more high-risk characteristics at study entry and a 2-fold increase in clinical events during follow-up, but less major bleeding. The primary end point (composite of cardiovascular death, myocardial infarction, and stroke) was reduced to a similar extent by ticagrelor among patients with (19.6% vs 21.4%; adjusted hazard ratio [HR], 0.91 [0.67, 1.24]) and without (9.2% vs 11.0%; adjusted HR, 0.86 [0.77, 0.96]; P(interaction) = .73) prior CABG. Major bleeding was similar with ticagrelor versus clopidogrel among patients with (8.1% vs 8.7%; adjusted HR, 0.89 [0.55, 1.47]) and without (11.8% vs 11.4%; HR, 1.08 [0.98, 1.20]; P(interaction) = .46) prior CABG. CONCLUSIONS Prior-CABG patients presenting with acute coronary syndrome are a high-risk cohort for death and recurrent cardiovascular events but have a lower risk for major bleeding. Similar to the results in no-prior-CABG patients, ticagrelor was associated with a reduction in ischemic events without an increase in major bleeding.
Resumo:
Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population. Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years. Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.
Resumo:
The human coronary collateral circulation is prognostically relevant. The understanding of collateral formation and its determinants may guide future therapeutic strategies aiming at promoting collateral growth and functionality, and hence reducing the global burden of coronary artery disease (CAD).
Resumo:
BACKGROUND The function of naturally existing internal mammary (IMA)-to-coronary artery bypasses and their quantitative effect on myocardial ischemia are unknown. METHODS AND RESULTS The primary end point of this study was collateral flow index (CFI) obtained during two 1-minute coronary artery balloon occlusions, the first with and the second without simultaneous distal IMA occlusion. The secondary study end point was the quantitatively determined intracoronary ECG ST-segment elevation. CFI is the ratio of simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. A total of 180 pairs of CFI measurements were performed among 120 patients. With and without IMA occlusion, CFI was 0.110±0.074 and 0.096±0.072, respectively (P<0.0001). The difference of CFI obtained in the presence minus CFI obtained in the absence of IMA occlusion was highest and most consistently positive during left IMA with left anterior descending artery occlusion and during right IMA with right coronary artery occlusion (ipsilateral occlusions): 0.033±0.044 and 0.025±0.027, respectively. This CFI difference was absent during right IMA with left anterior descending artery occlusion and during left IMA with right coronary artery occlusion (contralateral occlusions): -0.007±0.034 and 0.001±0.023, respectively (P=0.0002 versus ipsilateral occlusions). The respective CFI differences during either IMA with left circumflex artery occlusion were inconsistently positive. Intracoronary ECG ST-segment elevations were significantly reduced during ipsilateral IMA occlusions but not during contralateral or left circumflex artery occlusions. CONCLUSION There is a functional, ischemia-reducing extracardiac coronary artery supply via ipsilateral but not via contralateral natural IMA bypasses. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCTO1676207.
Resumo:
AIMS Due to a high burden of systemic cardiovascular events, current guidelines recommend the use of statins in all patients with peripheral artery disease (PAD). We sought to study the impact of statin use on limb prognosis in patients with symptomatic PAD enrolled in the international REACH registry. METHODS Statin use was assessed at study enrolment, as well as a time-varying covariate. Rates of the primary adverse limb outcome (worsening claudication/new episode of critical limb ischaemia, new percutaneous/surgical revascularization, or amputation) at 4 years and the composite of cardiovascular death/myocardial infarction/stroke were compared among statin users vs. non-users. RESULTS A total of 5861 patients with symptomatic PAD were included. Statin use at baseline was 62.2%. Patients who were on statins had a significantly lower risk of the primary adverse limb outcome at 4 years when compared with those who were not taking statins [22.0 vs. 26.2%; hazard ratio (HR), 0.82; 95% confidence interval (CI), 0.72-0.92; P = 0.0013]. Results were similar when statin use was considered as a time-dependent variable (P = 0.018) and on propensity analysis (P < 0.0001). The composite of cardiovascular death/myocardial infarction/stroke was similarly reduced (HR, 0.83; 95% CI, 0.73-0.96; P = 0.01). CONCLUSION Among patients with PAD in the REACH registry, statin use was associated with an ∼18% lower rate of adverse limb outcomes, including worsening symptoms, peripheral revascularization, and ischaemic amputations. These findings suggest that statin therapy not only reduces the risk of adverse cardiovascular events, but also favourably affects limb prognosis in patients with PAD.
Resumo:
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Resumo:
INTRODUCTION Anemia and renal impairment are important co-morbidities among patients with coronary artery disease undergoing Percutaneous Coronary Intervention (PCI). Disease progression to eventual death can be understood as the combined effect of baseline characteristics and intermediate outcomes. METHODS Using data from a prospective cohort study, we investigated clinical pathways reflecting the transitions from PCI through intermediate ischemic or hemorrhagic events to all-cause mortality in a multi-state analysis as a function of anemia (hemoglobin concentration <120 g/l and <130 g/l, for women and men, respectively) and renal impairment (creatinine clearance <60 ml/min) at baseline. RESULTS Among 6029 patients undergoing PCI, anemia and renal impairment were observed isolated or in combination in 990 (16.4%), 384 (6.4%), and 309 (5.1%) patients, respectively. The most frequent transition was from PCI to death (6.7%, 95% CI 6.1-7.3), followed by ischemic events (4.8%, 95 CI 4.3-5.4) and bleeding (3.4%, 95% CI 3.0-3.9). Among patients with both anemia and renal impairment, the risk of death was increased 4-fold as compared to the reference group (HR 3.9, 95% CI 2.9-5.4) and roughly doubled as compared to patients with either anemia (HR 1.7, 95% CI 1.3-2.2) or renal impairment (HR 2.1, 95% CI 1.5-2.9) alone. Hazard ratios indicated an increased risk of bleeding in all three groups compared to patients with neither anemia nor renal impairment. CONCLUSIONS Applying a multi-state model we found evidence for a gradient of risk for the composite of bleeding, ischemic events, or death as a function of hemoglobin value and estimated glomerular filtration rate at baseline.
Resumo:
OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).
Resumo:
Aortic valve stenosis and coronary artery disease (CAD) frequently coexist in elderly patients selected for transcatheter aortic valve implantation (TAVI). Therapeutic strategies to manage concomitant obstructive CAD are therefore an important consideration in the overall management of patients with severe aortic stenosis (AS) undergoing TAVI. Conventional surgical aortic valve replacement and coronary artery bypass grafting is the treatment of choice for low and intermediate risk patients with symptomatic severe AS and concomitant obstructive CAD. However, TAVI and percutaneous coronary intervention (PCI) are viable alternative options for high-risk or inoperable patients presenting with symptomatic severe AS. PCI has been shown to be feasible and safe in selected high-risk or inoperable patients with symptomatic severe AS. However, the optimal timing of PCI relative to the TAVI procedure has been a subject of debate. The most frequent approch is staged PCI typically performed a few weeks prior to TAVI. However, concomitant PCI has also been shown to be a feasible and safe approach, particularly in patients with a low level of CAD complexity and an absence of severe renal impairment. Conversely, staged PCI should be considered in patients with higher degrees of CAD complexity, particularly in the presence of severe renal impairment. The aim of the present review is to discuss the safety and feasibility of performing PCI in elderly patients with severe AS and the optimal timing of PCI relative to the TAVI procedure using the most up-to-date available evidence.
Resumo:
CONTEXT Subclinical hypothyroidism has been associated with increased risk of coronary heart disease (CHD), particularly with thyrotropin levels of 10.0 mIU/L or greater. The measurement of thyroid antibodies helps predict the progression to overt hypothyroidism, but it is unclear whether thyroid autoimmunity independently affects CHD risk. OBJECTIVE The objective of the study was to compare the CHD risk of subclinical hypothyroidism with and without thyroid peroxidase antibodies (TPOAbs). DATA SOURCES AND STUDY SELECTION A MEDLINE and EMBASE search from 1950 to 2011 was conducted for prospective cohorts, reporting baseline thyroid function, antibodies, and CHD outcomes. DATA EXTRACTION Individual data of 38 274 participants from six cohorts for CHD mortality followed up for 460 333 person-years and 33 394 participants from four cohorts for CHD events. DATA SYNTHESIS Among 38 274 adults (median age 55 y, 63% women), 1691 (4.4%) had subclinical hypothyroidism, of whom 775 (45.8%) had positive TPOAbs. During follow-up, 1436 participants died of CHD and 3285 had CHD events. Compared with euthyroid individuals, age- and gender-adjusted risks of CHD mortality in subclinical hypothyroidism were similar among individuals with and without TPOAbs [hazard ratio (HR) 1.15, 95% confidence interval (CI) 0.87-1.53 vs HR 1.26, CI 1.01-1.58, P for interaction = .62], as were risks of CHD events (HR 1.16, CI 0.87-1.56 vs HR 1.26, CI 1.02-1.56, P for interaction = .65). Risks of CHD mortality and events increased with higher thyrotropin, but within each stratum, risks did not differ by TPOAb status. CONCLUSIONS CHD risk associated with subclinical hypothyroidism did not differ by TPOAb status, suggesting that biomarkers of thyroid autoimmunity do not add independent prognostic information for CHD outcomes.
Resumo:
Ischemia-reperfusion has been reported to be associated with augmented oxidative stress in the course of surgery, which might be causally involved in the onset of atrial fibrillation (AF), the most common arrhythmia after cardiac surgery. We hypothesized that supplementation of antioxidants and n-3 polyunsaturated fatty acids (n-3 PUFAs) might lower the incidence of AF following coronary artery bypass graft (CABG) surgery. In the present study, by monitoring oxidative stress in the course of CABG surgery, we analyzed the efficacy of vitamins (ascorbic acid and α-tocopherol) and/or n-3 PUFAs (eicosapentaenoic acid and docosahexaenoic acid). Subjects (n = 75) were divided into 4 subgroups: control, vitamins, n-3 PUFAs, and a combination of vitamins and n-3 PUFAs. Fluorescent techniques were used to measure the antioxidative capacity, i.e. ability to inhibit oxidation. Total peroxides, endogenous peroxidase activity, and antibodies against oxidized LDL (oLAb) were used as serum oxidative stress biomarkers. Post-operative increase in oxidative stress was associated with the consumption of antioxidants and a simultaneous onset of AF. This was confirmed through an increased peroxide level and a decreased oLAb titer in control and n-3 PUFAs groups, indicating the binding of antibodies to oxidative modified epitopes. In both subgroups that were supplemented with vitamins, total peroxides decreased, and the maintenance of a constant IgG antibody titer was facilitated. However, treatment with vitamins or n-3 PUFAs was inefficient with respect to AF onset and its duration. We conclude that the administration of vitamins attenuates post-operative oxidative stress in the course of CABG surgery.
Resumo:
OBJECTIVES Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary artery bypass grafting (CABG) by electroencephalogram P300 wave event-related potentials and number connection test (NCT) as metrics of cognitive function. METHODS Cognitive brain function was assessed in 31 patients in 2013 with a mean age of 65 years [standard deviation (SD) 10] undergoing CABG by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds) directly prior to intervention, 7 days after and 3 months later. Number connection test, serving as method of control, was performed simultaneously in all patients. RESULTS Seven days following CABG, cognitive P300 evoked potentials were comparable with preoperative baseline values [vertex (Cz) 376 (SD 11) ms vs 378 (18) ms, P = 0.39; frontal (Fz) 377 (11) vs 379 (21) ms, P = 0.53]. Cognitive brain function at 3 months was compared with baseline values [(Cz) 376 (11) ms vs 371 (14 ms) P = 0.09; (Fz) 377 (11) ms vs 371 (15) ms, P = 0.04]. Between the first postoperative measurement and 3 months later, significant improvement was observed [(Cz) 378 (18) ms vs 371 (14) ms, P = 0.03; (Fz) 379 (21) vs 371 (15) ms, P = 0.02]. Similar clearly corresponding patterns could be obtained via the number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (P = 0.05) and (Fz) results (P = 0.04). CONCLUSIONS MECC does not adversely affect cognitive brain function after CABG. Additionally, these patients experience a substantial significant cognitive improvement after 3 months, evidentiary proving that the concept of MECC ensures safety and outcome in terms of brain function.
Resumo:
BACKGROUND Antifibrinolytics have been used for 2 decades to reduce bleeding in cardiac surgery. MDCO-2010 is a novel, synthetic, serine protease inhibitor. We describe the first experience with this drug in patients. METHODS In this phase II, double-blind, placebo-controlled study, 32 patients undergoing isolated primary coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to 1 of 5 increasing dosage groups of MDCO-2010. The primary aim was to evaluate pharmacokinetics (PK) with assessment of plasmatic concentrations of the drug, short-term safety, and tolerance of MDCO-2010. Secondary end points were influence on coagulation, chest tube drainage, and transfusion requirements. RESULTS PK analysis showed linear dosage-proportional correlation between MDCO-2010 infusion rate and PK parameters. Blood loss was significantly reduced in the 3 highest dosage groups compared with control (P = 0.002, 0.004 and 0.011, respectively). The incidence of allogeneic blood product transfusions was lower with MDCO-2010 4/24 (17%) vs 4/8 (50%) in the control group. MDCO-2010 exhibited dosage-dependent antifibrinolytic effects through suppression of D-dimer generation and inhibition of tissue plasminogen activator-induced lysis in ROTEM analysis as well as anticoagulant effects demonstrated by prolongation of activated clotting time and activated partial thromboplastin time. No systematic differences in markers of end organ function were observed among treatment groups. Three patients in the MDCO-2010 groups experienced serious adverse events. One patient experienced intraoperative thrombosis of venous grafts considered possibly related to the study drug. No reexploration for mediastinal bleeding was required, and there were no deaths. CONCLUSIONS This first-in-patient study demonstrated dosage-proportional PK for MDCO-2010 and reduction of chest tube drainage and transfusions in patients undergoing primary coronary artery bypass grafting. Antifibrinolytic and anticoagulant effects were demonstrated using various markers of coagulation. MDCO-2010 was well tolerated and showed an acceptable initial safety profile. Larger multi-institutional studies are warranted to further investigate the safety and efficacy of this compound.