220 resultados para computed tomography images


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Endoscopic or microscopic surgery for chronic rhinosinusitis with or without nasal polyps is a routine intervention in daily practice. It is often a delicate and difficult minimally invasive intervention in a narrow space, with a tunnel view of 4 mm in the case of endoscopy and frequent bleeding in chronically inflamed tissue. Therefore, orientation in such a "labyrinth" is often difficult. In the case of polyp recurrence or tumors, the normal anatomical landmarks are often missing, which renders orientation even more difficult. In such cases, computer-aided navigation together with images such as those from computed tomography or magnetic resonance imaging can support the surgeon to make the operation more accurate and, in some cases, faster. Computer-aided surgery also has great potential for education.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The objective of the study was to evaluate tissue reactions such as bone genesis, cartilage genesis and graft materials in the early phase of lumbar intertransverse process fusion in a rabbit model using computed tomography (CT) imaging with CT intensity (Hounsfield units) measurement, and to compare these data with histological results. MATERIALS AND METHODS: Lumbar intertransverse process fusion was performed on 18 rabbits. Four graft materials were used: autograft bone (n = 3); collagen membrane soaked with recombinant human bone morphogenetic protein-2 (rhBMP-2) (n = 5); granular calcium phosphate (n = 5); and granular calcium phosphate coated with rhBMP-2 (n = 5). All rabbits were euthanized 3 weeks post-operatively and lumbar spines were removed for CT imaging and histological examination. RESULTS: Computed tomography imaging demonstrated that each fusion mass component had the appropriate CT intensity range. CT also showed the different distributions and intensities of bone genesis in the fusion masses between the groups. Each component of tissue reactions was identified successfully on CT images using the CT intensity difference. Using CT color mapping, these observations could be easily visualized, and the results correlated well with histological findings. CONCLUSIONS: The use of CT intensity is an effective approach for observing and comparing early tissue reactions such as newly synthesized bone, newly synthesized cartilage, and graft materials after lumbar intertransverse process fusion in a rabbit model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: In the acute respiratory distress syndrome potentially recruitable lung volume is currently discussed. (3)He-magnetic resonance imaging ((3)He-MRI) offers the possibility to visualize alveolar recruitment directly. METHODS: With the approval of the state animal care committee, unilateral lung damage was induced in seven anesthetized pigs by saline lavage of the right lungs. The left lung served as an intraindividual control (healthy lung). Unilateral lung damage was confirmed by conventional proton MRI and spiral-CT scanning. The total aerated lung volume was determined both at a positive end-expiratory pressure (PEEP) of 0 and 10 mbar from three-dimensionally reconstructed (3)He images, both for healthy and damaged lungs. The fractional increase of aerated volume in damaged and healthy lungs, followed by a PEEP increase from 0 to 10 mbar, was compared. RESULTS: Aerated gas space was visualized with a high spatial resolution in the three-dimensionally reconstructed (3)He-MR images, and aeration defects in the lavaged lung matched the regional distribution of atelectasis in proton MRI. After recruitment and PEEP increase, the aerated volume increased significantly both in healthy lungs from 415 ml [270-445] (median [min-max]) to 481 ml [347-523] and in lavaged lungs from 264 ml [71-424] to 424 ml [129-520]. The fractional increase in lavaged lungs was significantly larger than that in healthy lungs (healthy: 17% [11-38] vs. lavage: 42% [14-90] (P=0.031). CONCLUSION: The (3)He-MRI signal might offer an experimental approach to discriminate atelectatic vs. poor aerated lung areas in a lung damage animal model. Our results confirm the presence of potential recruitable lung volume by either alveolar collapse or alveolar flooding, in accordance with previous reports by computed tomography.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fractures and soft-tissue injuries of the neck are of great importance in forensic pathology, as they help in assessing whether strangulation took place, and if so, how severely. In this study, we examined the usefulness of post-mortem imaging with multislice computed tomography (MSCT) in detecting lesions of the laryngohyoid structures and the surrounding soft-tissues. For this purpose, we examined MSCT images of the neck of eight deceased persons who had suffered different types of strangulation and compared the findings with those obtained at the subsequent forensic autopsy. In six of the eight cases (75%), the fracture findings at autopsy were concordant with those found with MSCT. In the two non-congruent cases, MSCT revealed fractures, which were not discovered at autopsy. Soft-tissue haemorrhages were detected by autopsy in five cases, but only in one case with MSCT. MSCT does not suffice in detecting soft-tissue injuries. These preliminary results are promising regarding the detection of fractures in strangulation cases. If these results can be confirmed in larger studies, we believe that post-mortem MSCT may serve - in combination with a thorough external examination and a profound incident-scene investigation - as a useful decision-making tool regarding the necessity of further examinations, i.e. autopsy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the present study is to define an optimally performing computer-aided diagnosis (CAD) architecture for the classification of liver tissue from non-enhanced computed tomography (CT) images into normal liver (C1), hepatic cyst (C2), hemangioma (C3), and hepatocellular carcinoma (C4). To this end, various CAD architectures, based on texture features and ensembles of classifiers (ECs), are comparatively assessed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, a computer-aided diagnostic (CAD) system for the classification of hepatic lesions from computed tomography (CT) images is presented. Regions of interest (ROIs) taken from nonenhanced CT images of normal liver, hepatic cysts, hemangiomas, and hepatocellular carcinomas have been used as input to the system. The proposed system consists of two modules: the feature extraction and the classification modules. The feature extraction module calculates the average gray level and 48 texture characteristics, which are derived from the spatial gray-level co-occurrence matrices, obtained from the ROIs. The classifier module consists of three sequentially placed feed-forward neural networks (NNs). The first NN classifies into normal or pathological liver regions. The pathological liver regions are characterized by the second NN as cyst or "other disease." The third NN classifies "other disease" into hemangioma or hepatocellular carcinoma. Three feature selection techniques have been applied to each individual NN: the sequential forward selection, the sequential floating forward selection, and a genetic algorithm for feature selection. The comparative study of the above dimensionality reduction methods shows that genetic algorithms result in lower dimension feature vectors and improved classification performance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The complexity of the equine skull makes the temporomandibular joint a difficult area to evaluate radiographically. The goal of this study was to determine the optimal angle for a complementary radiographic projection of the equine temporomandibular joint based on a computed tomography (CT) cadaver study. CT was performed on six equine cadaver heads of horses that were euthanized for other reasons than temporomandibular joint disease. After the CT examination, 3D reconstruction of the equine skull was performed to subjectively determine the angle for a complementary radiographic projection of the temporomandibular joint. The angle was measured on the left and right temporomandibular joint of each head. Based on the measurements obtained from the CT images, a radiographic projection of the temporomandibular joint in a rostra-145 degrees ventral-caudodorsal oblique (R45 degrees V-CdDO) direction was developed by placing the X-ray unit 30 degrees laterally, maintaining at the same time the R45 degrees V-CdDO angle (R45 degrees V30 degrees L-CdDLO). This radiographic projection was applied to all cadaver heads and on six live horses. In three of the live horses abnormal findings associated with the temporomandibular joint were detected. We conclude that this new radiographic projection of the temporomandibular joint provides superior visualization of the temporomandibular joint space and the articular surface of the mandibular condyle.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION The aims of this study were to compare lateral cephalograms with other radiologic methods for diagnosing suspected fusions of the cervical spine and to validate the assessment of congenital fusions and osteoarthritic changes against the anatomic truth. METHODS Four cadaver heads were selected with fusion of vertebrae C2 and C3 seen on a lateral cephalogram. Multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) were performed and assessed by 5 general radiologists and 5 oral radiologists, respectively. Vertebrae C2 and C3 were examined for osseous fusions, and the left and right facet joints were diagnosed for osteoarthritis. Subsequently, the C2 and C3 were macerated and appraised by a pathologist. Descriptive analysis was performed, and interrater agreements between and within the groups were computed. RESULTS All macerated specimens showed osteoarthritic findings of varying degrees, but no congenital bony fusion. All observers agreed that no fusion was found on MDCT or CBCT. They disagreed on the prevalence of osteoarthritic deformities (general radiologists/MDCT, 100%; oral radiologists/CBCT, 93.3%) and joint space assessment in the facet joints (kappa = 0.452). The agreement within the rater groups differed considerably (general radiologists/MDCT, kappa = 0.612; oral radiologists/CBCT, kappa = 0.240). CONCLUSIONS Lateral cephalograms do not provide dependable data to assess the cervical spine for fusions and cause false-positive detections. Both MDCT interpreted by general radiologists and CBCT interpreted by oral radiologists are reliable methods to exclude potential fusions. Degenerative osteoarthritic changes are diagnosed more accurately and consistently by general radiologists evaluating MDCT.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to analyze the width and height of edentulous sites in the posterior maxilla using cone beam computed tomography (CBCT) images from patients referred for implant therapy. A total of 122 CBCT scans were included in the analysis, resulting in a sample size of 252 edentulous sites. The orofacial crest width was measured in coronal slices, perpendicular to the alveolar ridge. The bone height was analyzed in the respective sagittal slices. Additionally, the following secondary outcome parameters were evaluated: the morphology of the sinus floor, the presence of septa in the maxillary sinus, and the thickness of the sinus membrane. The mean crest width for all analyzed sites was 8.28 mm, and the mean bone height was 7.22 mm. The percentage of patients with a crest width of less than 6 mm was 27% in premolar sites and 7.8% in molar sites. The bone height decreased from premolar to molar areas, with a high percentage of first and second molar sites exhibiting a bone height of less than 5 mm (54.12% and 44.64%, respectively). Regarding the morphology of the sinus floor, 53% of the edentulous sites exhibited a flat configuration. A septum was present in 67 edentulous sites (26.59%). Analysis of the sinus membrane revealed 88 sites (34.9%) with increased mucosal thickness (> 2 mm). For the crest width, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. For the crest width and mean bone height, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. The study confirmed that a high percentage of edentulous sites in the posterior maxilla do require sinus floor elevation to allow the placement of dental implants. Therefore, a detailed three-dimensional radiograph using CBCT is indicated in most patients for proper treatment planning.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

STUDY DESIGN Descriptive anatomical study on ovine and human cadaveric lumbar spinal segments. OBJECTIVE To describe the alternative transpedicular approach to deliver therapeutic agents into intervertebral disc (IVD). SUMMARY OF BACKGROUND DATA The present delivery approach of therapeutic agents (growth factors/cells/hydrogels) within the IVD is through injection, via the annulus fibrosus (AF). However, it has recently been demonstrated that small needle puncture of the AF leads to further degeneration and disc herniation. In addition, the injected material has a high chance to be extruded through the AF injury. METHODS Lumbar ovine and human spinal segments were used. Under fluoroscopy, a 2-mm Kirschner wire was introduced in the caudal vertebra through the pedicle and the inferior endplate to the nucleus pulposus. Gross anatomy analysis and high-resolution peripheral quantitative computed tomography (HR-pQCT) were performed to assess the right position of the wire in pedicles. Discography and nucleotomy were performed using a 14G cannula insertion or a 2-mm arthroscopic shaver blade, respectively. Nucleoplasty was also performed with agarose gel/contrast agent and imaged with HR-pQCT. RESULTS Gross anatomy, fluoroscopy, and HR-pQCT images showed that the nucleus pulposus could be approached through the endplate via the pedicle without affecting the spinal canal and the neural foramina. The contrast agent was delivered into the IVD and nucleus pulposus was removed from the disc and filled with agarose gel. CONCLUSION This study describes how a transpedicular approach can be used as an alternative route to deliver therapeutic agents to the disc without disruption of the AF showing the potential use of this technique in preclinical research and highlighting its clinical relevance for IVD regeneration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Conventional cross-sectional imaging with computed tomography and magnetic resonance imaging (MRI) has limited accuracy for lymph node (LN) staging in bladder and prostate cancer patients. Objective To prospectively assess the diagnostic accuracy of combined ultrasmall superparamagnetic particles of iron oxide (USPIO) MRI and diffusion-weighted (DW) MRI in staging of normal-sized pelvic LNs in bladder and/or prostate cancer patients. Design, setting, and participants Examinations with 3-Tesla MRI 24–36 h after administration of USPIO using conventional MRI sequences combined with DW-MRI (USPIO-DW-MRI) were performed in 75 patients with clinically localised bladder and/or prostate cancer staged previously as N0 by conventional cross-sectional imaging. Combined USPIO-DW-MRI findings were analysed by three independent readers and correlated with histopathologic LN findings after extended pelvic LN dissection (PLND) and resection of primary tumours. Outcome measurements and statistical analysis Sensitivity and specificity for LN status of combined USPIO-DW-MRI versus histopathologic findings were evaluated per patient (primary end point) and per pelvic side (secondary end point). Time required for combined USPIO-DW-MRI reading was assessed. Results and limitations At histopathologic analysis, 2993 LNs (median: 39 LNs; range: 17–68 LNs per patient) with 54 LN metastases (1.8%) were found in 20 of 75 (27%) patients. Per-patient sensitivity and specificity for detection of LN metastases by the three readers ranged from 65% to 75% and 93% to 96%, respectively; sensitivity and specificity per pelvic side ranged from 58% to 67% and 94% to 97%, respectively. Median reading time for the combined USPIO-DW-MRI images was 9 min (range: 3–26 min). A potential limitation is the absence of a node-to-node correlation of combined USPIO-DW-MRI and histopathologic analysis. Conclusions Combined USPIO-DW-MRI improves detection of metastases in normal-sized pelvic LNs of bladder and/or prostate cancer patients in a short reading time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose Femoral fracture is a common medical problem in osteoporotic individuals. Bone mineral density (BMD) is the gold standard measure to evaluate fracture risk in vivo. Quantitative computed tomography (QCT)-based homogenized voxel finite element (hvFE) models have been proved to be more accurate predictors of femoral strength than BMD by adding geometrical and material properties. The aim of this study was to evaluate the ability of hvFE models in predicting femoral stiffness, strength and failure location for a large number of pairs of human femora tested in two different loading scenarios. Methods Thirty-six pairs of femora were scanned with QCT and total proximal BMD and BMC were evaluated. For each pair, one femur was positioned in one-legged stance configuration (STANCE) and the other in a sideways configuration (SIDE). Nonlinear hvFE models were generated from QCT images by reproducing the same loading configurations imposed in the experiments. For experiments and models, the structural properties (stiffness and ultimate load), the failure location and the motion of the femoral head were computed and compared. Results In both configurations, hvFE models predicted both stiffness (R2=0.82 for STANCE and R2=0.74 for SIDE) and femoral ultimate load (R2=0.80 for STANCE and R2=0.85 for SIDE) better than BMD and BMC. Moreover, the models predicted qualitatively well the failure location (66% of cases) and the motion of the femoral head. Conclusions The subject specific QCT-based nonlinear hvFE model cannot only predict femoral apparent mechanical properties better than densitometric measures, but can additionally provide useful qualitative information about failure location.