333 resultados para VIDEO-ASSISTED THORACIC SURGERY
Resumo:
BACKGROUND. The high rate of reperfusion injury in clinical lung transplantation mandates significant improvements in lung preservation. Innovations should be validated using standardized and low-cost experimental models. METHODS. The model introduced here is analyzed by comparing global lung function after varying ischemic times (2, 4, 8, 16, and 24 hours). A rat double-lung block is flush-perfused, and the main pulmonary artery and left atrium are connected to the left pulmonary artery and vein of a syngeneic recipient using a T-shaped stent. With pressure side ports and incorporated flow crystals, measurement of vascular resistance and graft oxygenation can be performed. The transplant is ventilated separately, and compliance and resistance are determined. RESULTS. The increase in the ischemic interval from 2 to 24 hours caused an increase in the alveolar arterial oxygen difference from 220 +/- 20 to 600 +/- 34 mm Hg, pulmonary vascular resistance from 198 +/- 76 to 638 +/- 212 mm Hg.mL-1.min-1, and resistance to airflow from 274 +/- 50 to 712 +/- 30 cm H2O/L H2O, and a decrease in pulmonary compliance from 0.4 +/- 0.05 to 0.12 +/- 0.06 mL/cm H2O. CONCLUSIONS. This in situ, syngeneic rat lung transplantation model offers an alternative to large animal models for verification of lung preservation solutions and for modification of donor or recipient treatment regimens.
Resumo:
In the present report the prevalence, severity, and risk factors of tricuspid valve regurgitation (TR) in 251 heart transplant recipients have been analyzed retrospectively. Tricuspid valve function was studied by color-flow Doppler echocardiogram and annual heart catheterization. The presence or severity of TR was graded on a scale from 0 (no TR) to 4 (severe). Additional postoperative data included rate of rejection, number of endomyocardial biopsies, incidence of transplant vasculopathy, and preoperative and postoperative hemodynamics. The incidence of grade 3 TR increases from 5% at 1 year to 50% at 4 years after transplantation. Multivariate analysis showed rate of rejection and donor heart weight to be significant risk factors. The ischemic intervals as well as the preoperative and postoperative pulmonary hemodynamics did not affect the severity or prevalence of TR. These results indicate that various factors appear to have an impact on the development of TR and that the prevalence might be lowered by a reduction of the number of biopsies performed and when possible, oversizing of donor hearts.
Resumo:
The endomyocardial biopsy (EMB) in heart transplant recipients has been considered the "gold standard" for diagnosis of graft rejection (REJ). The purpose of this retrospective study is to develop long-term strategies (frequency and postoperative duration of EMB) for REJ monitoring. Between 1985 and 1992, 346 patients (mean age 44.5 years, female patients = 14%) received 382 heart grafts. For graft surveillance EMBs were performed according to a fixed schedule depending on postoperative day and the results of previous biopsies. In the first year the average number (no.) of EMBs/patient was 20 with 19% positive for REJ in the first quarter, dropping to 7% REJ/EMB by the end of the first year. The percentage of REJ/EMB declined annually from 4.7% to 4.5%, 2.2% and less than 1% after the fifth year. Individual biopsy results in the first 3 postoperative months had little predictive value. Patients with fewer than two REJ (group 1), vs patients with two or more REJ in the first 6 postoperative months (group 2), were significantly less likely to reject in the second half of the first year (group 1: 0.29 +/- 0.6 REJ/patient; group 2:0.83 +/- 1.3 REJ/patient; P < 0.001) and third postoperative year (group 1:0.12 +/- 0.33 REJ/patients; group 2:0.46 +/- 0.93 REJ/patient; P < 0.05). In conclusion, routine EMBs in the first 3 postoperative months have only limited predictive value, however the number of routine EMBs can be drastically reduced later depending on the intermediate postoperative REJ pattern.
Resumo:
The toxicity of long-term immunosuppressive therapy has become a major concern in long-term follow-up of heart transplant recipients. In this respect the quality of renal function is undoubtedly linked to cyclosporin A (CsA) drug levels. In cardiac transplantation, specific CsA trough levels have historically been maintained between 250 and 350 micrograms/L in many centers without direct evidence for the necessity of such high levels while using triple-drug immunosuppression. This retrospective analysis compares the incidence of acute and chronic graft rejection as well as overall mortality between groups of patients with high (250 to 350 micrograms/L) and low (150 to 250 micrograms/L) specific CsA trough levels. A total of 332 patients who underwent heart transplantation between October 1985 and October 1992 with a minimum follow-up of 30 days were included in this study (46 women and 276 men; aged, 44 +/- 12 years; mean follow-up, 1,122 +/- 777 days). Standard triple-drug immunosuppression included first-year specific CsA target trough levels of 250 to 300 micrograms/L. Patients were grouped according to their average creatinine level in the first postoperative year (group I, < 130 mumol/L, n = 234; group II, > or = 130 mumol/L, n = 98). The overall 5-year survival excluding the early 30-day mortality was 92% (group I, 216/232) and 91% (group II, 89/98) with 75% of the mortality due to chronic rejection. The rate of rejection for the entire follow-up period was similar in both groups (first year: group I, 3.2 +/- 2.6 rejection/patient/year; group II, 3.6 +/- 2.7 rejection/patient/year; p = not significant).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Prolongation of the safe period of ischemia of the heart is an efficient way to overcome donor organ shortage, as demonstrated in renal and hepatic transplantation. We present the results of a prospective, randomized study comparing preservation with University of Wisconsin solution (UWS) versus St. Thomas' Hospital solution (STS) in clinical heart transplantation. A total of 39 patients were enrolled in the study (n = 20 for UWS and n = 19 for STS). Hemodynamic, electron microscopic, and biochemical evaluation did not reveal any significant differences in postoperative myocardial performance. Only the number of intraoperative defibrillations (0.82 for UWS versus 1.7 for STS) and the rhythm stability after reperfusion (13/20 UWS hearts versus 6/19 STS hearts in sinus rhythm) were significantly different. Heart preservation with UWS and STS appears to be of comparable efficacy at mean ischemic times of less than 4 hours.
Resumo:
The introduction of cyclosporine A (CyA) into the immunosuppressive therapy has significantly improved the results of heart transplantation (HTX). Its nephrotoxicity and hepatotoxicity, however, often limit the perioperative and postoperative use of this drug. The purpose of this retrospective study was to evaluate the effect of early postoperative CyA blood levels on the incidence of early as well as late cardiac rejection and patients' survival. Between October 1985 and June 1991, HTX was performed in 311 patients. Standard immunosuppression consisted of azathioprine (1-2 mg/kg), prednisolone (0.5 to 0.1 mg/kg) and CyA. Rabbit-antithymocyte-globulin (RATG - 1.5 mg/kg) was administered for the first 4 days postoperatively. Moderate rejection was treated with 3 x 500 mg methylprednisolone, severe rejection with RATG (1.5 mg/kg three times a day). Patients were excluded from this study because of a positive cross-matching, early death unrelated to rejection or alternate forms of immunosuppression (n = 111). Follow-up was complete in 200 patients (mean age 44 +/- 11; 18 female, 182 male; 204,233 patient days) with a total of 5380 biopsies. The cohort was divided into group I (no CyA for day 0 to 2; n = 108) and group II (CyA during day 0 to 2; n = 92) according to the onset of CyA therapy. In 101 patients (group A) the mean CyA blood level was less than 150 ng/ml from day 0 to 14 and in 99 patients more than 150 ng/ml (group B).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
The occurrence of severe graft failure after lung transplantation which appears refractory to conventional treatment represents a difficult situation with regard to the therapeutic strategies available. Of 17 patients undergoing single lung transplantation at our center, 2 developed early graft failure. In both, temporary artificial cardiopulmonary support by means of extracorporeal membrane oxygenation became necessary as a bridge to retransplantation. Both patients were successfully retransplanted after 8 h and 232 h, respectively, of extra-corporeal support. Postoperatively, there was a variety of complications. The first patient completely recovered from temporary severe cerebral dysfunction diagnosed as "locked-in syndrome". She was discharged from hospital on the 93rd postoperative day and remains alive and well 10 months after her operation. The other patient recovered well early after retransplantation. Later, however, airway problems developed, requiring the implantation of endotracheal stents. Cachexia and several episodes of viral pneumonia contributed to the progressive deterioration of her clinical status. She finally died after being hospitalized for 5 months after the original operation. These two cases illustrate the feasibility of using extracorporeal membrane oxygenation as a bridge to pulmonary transplantation.
Resumo:
Direct revascularization of a bronchial artery has been proposed as a measure to alleviate the problem of bronchial ischemia after lung transplantation. To assess the effect of restoration of arterial blood flow to the transplanted bronchus, bronchial mucosal blood flow was measured in a model of modified unilateral lung transplantation in pigs. Laser Doppler velocimetry (LDV) and radioisotope studies using radio-labeled erythrocytes (RI) were used to measure blood flow at the donor main carina (DC) and upper lobe carina (DUC) after 3 h of reperfusion. The recipient carina was used as a reference point; values obtained by LDV and RI were expressed as percentage of blood flow at the recipient carina. Two groups of animals were studied. In group 1 (n = 6) standard unilateral transplantation was performed; in group 2 (n = 6) a left bronchial artery was reimplanted into the descending thoracic aorta of the recipient. No differences were observed between the two groups with respect to preoperative or postoperative gas exchange or hemodynamics. In group 1, bronchial blood flow at the DC was 37.6 +/- 2.2% (LDV) and 44.1 +/- 14.8% (RI) of reference blood flow. At the DUC, blood flow was 54.9 +/- 7.7% (LDV) and 61.6 +/- 25.7% (RI) of normal flow. In group 2, blood flow was increased at the DC as measured by LDV (55.3 +/- 17.1%; p less than 0.05) and by RI (60.8 +/- 25.3%; p less than 0.2). A similar increase was found at the DUC (LDV: 81.8 +/- 19.3%; p less than 0.05; RI: 88.6 +/- 31.0%; p less than 0.2). It is concluded that there is a significant gradient of blood flow from intra- to extrapulmonary airways after lung transplantation. Reimplantation of a bronchial artery results in significant improvement of graft bronchial blood flow. Restoration of bronchial perfusion to normal levels, however, cannot be achieved, suggesting a possible defect in the microcirculation of the donor airways.
Resumo:
We describe a case of massive embolization of atherosclerotic material during aortic cannulation and the surgical approach chosen to treat it, that is, retrograde cerebral perfusion and subtotal arch replacement in deep hypothermic circulatory arrest.
Resumo:
BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.
Resumo:
Here we investigate the expression of OCT4 human lung adenocarcinoma and bronchioloalveolar carcinoma (BAC) tumor biopsies and tumor-derived primary cell cultures. OCT4 has been detected in several human tumors suggesting a potentially critical role in tumorigenesis. We assessed the presence of OCT4 in clinical tumor samples of both adenocarcinoma and BAC at the cellular and transcriptional levels, respectively. Furthermore, we evaluated tumor-derived cell cultures for potential differences in OCT4 expression. Immunohistochemical analysis depicted OCT4 in 2 of 8 adenocarcinoma tumor samples and 3 of 5 BAC tumor samples, with no apparent difference in the degree of expression among the sections examined. These results were validated by transcript analysis. Flow cytometric assessment of 11 adenocarcinoma-derived cell cultures and 3 BAC-derived cell cultures revealed significantly higher OCT4 expression in adenocarcinoma tumors compared to their normal counterparts. This, however, was not observed in the BAC cultures. Comparative studies of OCT4 in adenocarcinoma and BAC tumor cell cultures demonstrated a dramatically higher expression in the former. The expression of OCT4 may represent a specific and effective target for therapeutic intervention in adenocarcinoma and BAC. In addition, the aberrant expression and distribution of OCT4 may indicate important parameters concerning the differences between adenocarcinoma and BAC.
Resumo:
PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.
Resumo:
BACKGROUND: This study analyzes the effects on coagulation and fibrinolysis comparing off-pump coronary artery bypass (OPCAB) and on-pump CABG operations. METHODS: In a prospective, nonrandomized, comparative evaluation, patients scheduled for elective myocardial revascularization were studied. Due to possible confounding factors patients with postoperative retransfusion of mediastinal shed blood were excluded. Nine patients underwent OPCAB operation and 16 underwent on-pump CABG. Activated clotting time (ACT) was adjusted to 250 seconds in OPCAB (81 +/- 18 [mean +/- SD] IU/kg heparin) and to more than 480 seconds in on-pump CABG (400 IU/kg heparin, additional 10,000 IU in pump prime). Perioperatively blood samples were collected and hematologic and hemostatic variables including fibrinopeptide A (FPA), fibrin monomer (FM), thrombin-antithrombin complex (TAT), and D-dimer were analyzed. RESULTS: Both groups showed comparable demographic variables. Number of grafts per patient was slightly higher in the on-pump group (3.6 +/- 0.6 versus 3.0 +/- 1.1, p = 0.23). The FPA levels did not differ significantly between the groups. The FM, TAT, and D-dimer values were significantly higher in on-pump CABG (p < 0.0001, p < 0.01, and p < 0.0001, respectively), reflecting increased coagulant and fibrinolytic activity. This was also the case when values were corrected for hemodilution. CONCLUSIONS: Despite lower systemic anticoagulation activation of coagulation and fibrinolysis is reduced in OPCAB compared with on-pump CABG. Reduced thrombin generation and reduced fibrinolytic activity in OPCAB indicates better preservation of hemostasis. We suggest the term "preserved hemostasis" instead of "hypercoagulant activity" with respect to OPCAB.