229 resultados para PERI-IMPLANT BONE
Resumo:
OBJECTIVE: Meticulous sealing of opened air cells in the petrous bone is necessary for the prevention of cerebrospinal fluid (CSF) fistulae after vestibular schwannoma surgery. We performed a retrospective analysis to determine whether muscle or fat tissue is superior for this purpose. METHODS: Between January 2001 and December 2006, 420 patients underwent retrosigmoidal microsurgical removal by a standardized procedure. The opened air cells at the inner auditory canal and the mastoid bone were sealed with muscle in 283 patients and with fat tissue in 137 patients. Analysis was performed regarding the incidence of postoperative CSF fistulae and correlation with the patient's sex and tumor grade. RESULTS: The rate of postoperative CSF leak after application of fat tissue was lower (2.2%) than after use of muscle (5.7%). Women had less postoperative CSF leakage (3.4%) than men (5.6%). There was an inverse correlation with tumor grade. Patients with smaller tumors seemed to have a higher rate of CSF leakage than those with large tumors without hydrocephalus. Only large tumors with severe dislocation of the brainstem causing hydrocephalus showed a higher incidence of CSF leaks. CONCLUSION: Fat implantation is superior to muscle implantation for the prevention of CSF leakage after vestibular schwannoma surgery and should, therefore, be used for the sealing of opened air cells in cranial base surgery.
Resumo:
The application of implant-borne rehabilitations in residual alveolar ridges may be restricted by various anatomic conditions, as available bone height and characteristics. Here we report the clinical outcome of implants placed in severely resorbed posterior ridges, in addition to various implant-supported treatment modalities. Extra Oral implants (Straumann, Basel, Switzerland) with the intraosseous length of 2.5–5mm were installed in the posterior alveolar ridges. Following the healing period of 4–6 months, implants were exposed and included in the distal extensions of fixed and removable prosthesis. At recall appointments were collected surgical, clinical and radiological variables, including the evidence of adverse effects. An 8-years life table analysis was calculated. The treatment protocol was applied in thirty-five patients, presenting 31 removable and 4 fixed complete implant-supported dentures. A total of 61 Extra Oral implants were placed posterior to the distal implants, at the mean distance of 29.8mm (range 15.6–62.7mm). Three implants failed during the osteointegration phase, yielding an 8-year cumulative success rate of 92.24%. Following the osteointegration period, no major bone loss or other adverse events were found. The clinical results indicated that the Extra Oral implants may be successfully used in addition to the other, longer implants. Thus, a relatively long extension in the posterior region may be employed. With careful preoperative planning, this technique offers a simple and beneficial complementary treatment option for removable and fixed complete dentures.
Resumo:
INTRODUCTION: This report of 2 cases describes the diagnostic procedures used to identify 2 Stafne's bone cavities (SBC) found in unusually anterior locations in the mandible, both mimicking periapical lesions of endodontic origin. METHODS: In the first patient, a 47-year-old man, an SBC was diagnosed in the area of teeth #27, 28, and 29. In the second patient, a 62-year-old man, the SBC was a fortuitous finding, because this patient was referred for dental implant therapy. RESULTS: In both cases, the final diagnosis was achieved by using limited cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI). In both patients, the lingual bone cavity was found to be occupied by accessory salivary gland tissue. CONCLUSIONS: The combination of CBCT and MRI as noninvasive diagnostic techniques seems ideal to avoid surgical explorations, incisional biopsies, or enucleations of the lesion for diagnostic purposes.
Resumo:
The successful treatment of primary and secondary bone tumors in a huge number of cases remains one of the major unsolved challenges in modern medicine. Malignant primary bone tumor growth predominantly occurs in younger people, whereas older people predominantly suffer from secondary bone tumors since up to 85% of the most frequently occurring malignant solid tumors, such as lung, mammary, and prostate carcinomas, metastasize into the bone. It is well known that a tumor's course may be altered by its surrounding tissue. For this reason, reported here is the protocol for the surgical preparation of a cranial bone window in mice as well as the method to implant tumors in this bone window for further investigations of angiogenesis and other microcirculatory parameters in orthotopically growing primary or secondary bone tumors using intravital microscopy. Intravital microscopy represents an internationally accepted and sophisticated experimental method to study angiogenesis, microcirculation, and many other parameters in a wide variety of neoplastic and nonneoplastic tissues. Since most physiologic and pathophysiologic processes are active and dynamic events, one of the major strengths of chronic animal models using intravital microscopy is the possibility of monitoring the regions of interest in vivo continuously up to several weeks with high spatial and temporal resolution. In addition, after the termination of experiments, tissue samples can be excised easily and further examined by various in vitro methods such as histology, immunohistochemistry, and molecular biology.
Resumo:
PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.
Resumo:
This paper constitutes a summary of the consensus documents agreed at the First European Workshop on Implant Dentistry University Education held in Prague on 19-22 June 2008. Implant dentistry is becoming increasingly important treatment alternative for the restoration of missing teeth, as patients expectations and demands increase. Furthermore, implant related complications such as peri-implantitis are presenting more frequently in the dental surgery. This consensus paper recommends that implant dentistry should be an integral part of the undergraduate curriculum. Whilst few schools will achieve student competence in the surgical placement of implants this should not preclude the inclusion of the fundamental principles of implant dentistry in the undergraduate curriculum such as the evidence base for their use, indications and contraindications and treatment of the complications that may arise. The consensus paper sets out the rationale for the introduction of implant dentistry in the dental curriculum and the knowledge base for an undergraduate programme in the subject. It lists the competencies that might be sought without expectations of surgical placement of implants at this stage and the assessment methods that might be employed. The paper also addresses the competencies and educational pathways for postgraduate education in implant dentistry.
Resumo:
PURPOSE: The aim was (1) to evaluate the soft-tissue reaction of a synthetic polyethylene glycol (PEG) hydrogel used as a barrier membrane for guided bone regeneration (GBR) compared with a collagen membrane and (2) to test whether or not the application of this in situ formed membrane will result in a similar amount of bone regeneration as the use of a collagen membrane. MATERIAL AND METHODS: Tooth extraction and preparation of osseous defects were performed in the mandibles of 11 beagle dogs. After 3 months, 44 cylindrical implants were placed within healed dehiscence-type bone defects resulting in approximately 6 mm exposed implant surface. The following four treatment modalities were randomly allocated: PEG+autogenous bone chips, PEG+hydroxyapatite (HA)/tricalcium phosphate (TCP) granules, bioresorbable collagen membrane+autogenous bone chips and autogenous bone chips without a membrane. After 2 and 6 months, six and five dogs were sacrificed, respectively. A semi-quantitative evaluation of the local tolerance and a histomorphometric analysis were performed. For statistical analysis, repeated measures analysis of variance (ANOVA) and subsequent pairwise Student's t-test were applied (P<0.05). RESULTS: No local adverse effects in association with the PEG compared with the collagen membrane was observed clinically and histologically at any time-point. Healing was uneventful and all implants were histologically integrated. Four out of 22 PEG membrane sites revealed a soft-tissue dehiscence after 1-2 weeks that subsequently healed uneventful. Histomorphometric measurement of the vertical bone gain showed after 2 months values between 31% and 45% and after 6 months between 31% and 38%. Bone-to-implant contact (BIC) within the former defect area was similarly high in all groups ranging from 71% to 82% after 2 months and 49% to 91% after 6 months. However, with regard to all evaluated parameters, the PEG and the collagen membranes did not show any statistically significant difference compared with sites treated with autogenous bone without a membrane. CONCLUSION: The in situ forming synthetic membrane made of PEG was safely used in the present study, revealing no biologically significant abnormal soft-tissue reaction and demonstrated similar amounts of newly formed bone for defects treated with the PEG membrane compared with defects treated with a standard collagen membrane.
Resumo:
This case report presents the treatment sequence of a 56 years old patient after he developed periimplantitis at the implant in position of tooth 22. This implant was integrated in an overdenture reconstruction connected to a soldered screw retained gold bar. The entire 2-stage procedure of implant explantation, simultaneous bone augmentation and new implant placement is documented. The onlay-graft was performed by means of the Transfer-Ring-Control System (Meisinger). The existing gold bar could be resoldered and adapted to the new implant. Accordingly the overdenture was relined and the female retainer mounted. The treatment period covered almost one year.
Resumo:
STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.
Resumo:
OBJECTIVES: To analyze computer-assisted diagnostics and virtual implant planning and to evaluate the indication for template-guided flapless surgery and immediate loading in the rehabilitation of the edentulous maxilla. MATERIALS AND METHODS: Forty patients with an edentulous maxilla were selected for this study. The three-dimensional analysis and virtual implant planning was performed with the NobelGuide software program (Nobel Biocare, Göteborg, Sweden). Prior to the computer tomography aesthetics and functional aspects were checked clinically. Either a well-fitting denture or an optimized prosthetic setup was used and then converted to a radiographic template. This allowed for a computer-guided analysis of the jaw together with the prosthesis. Accordingly, the best implant position was determined in relation to the bone structure and prospective tooth position. For all jaws, the hypothetical indication for (1) four implants with a bar overdenture and (2) six implants with a simple fixed prosthesis were planned. The planning of the optimized implant position was then analyzed as follows: the number of implants was calculated that could be placed in sufficient quantity of bone. Additional surgical procedures (guided bone regeneration, sinus floor elevation) that would be necessary due the reduced bone quality and quantity were identified. The indication of template-guided, flapless surgery or an immediate loaded protocol was evaluated. RESULTS: Model (a) - bar overdentures: for 28 patients (70%), all four implants could be placed in sufficient bone (total 112 implants). Thus, a full, flapless procedure could be suggested. For six patients (15%), sufficient bone was not available for any of their planned implants. The remaining six patients had exhibited a combination of sufficient or insufficient bone. Model (b) - simple fixed prosthesis: for 12 patients (30%), all six implants could be placed in sufficient bone (total 72 implants). Thus, a full, flapless procedure could be suggested. For seven patients (17%), sufficient bone was not available for any of their planned implants. The remaining 21 patients had exhibited a combination of sufficient or insufficient bone. DISCUSSION: In the maxilla, advanced atrophy is often observed, and implant placement becomes difficult or impossible. Thus, flapless surgery or an immediate loading protocol can be performed just in a selected number of patients. Nevertheless, the use of a computer program for prosthetically driven implant planning is highly efficient and safe. The three-dimensional view of the maxilla allows the determination of the best implant position, the optimization of the implant axis, and the definition of the best surgical and prosthetic solution for the patient. Thus, a protocol that combines a computer-guided technique with conventional surgical procedures becomes a promising option, which needs to be further evaluated and improved.
Resumo:
INTRODUCTION: Using a rat model, we evaluated the kinetics and histomorphometry of ectopic bone formation in association with biomimetic implant coatings containing BMP-2. MATERIALS AND METHODS: One experimental and three control groups were set up: titanium-alloy discs coated with a biomimetically co-precipitated layer of calcium phosphate and BMP-2 [1.7 microg per disc (incorporated-BMP group)]; uncoated discs (control); discs biomimetically coated with a layer of calcium phosphate alone (control); and discs biomimetically coated with a layer of calcium phosphate bearing superficially adsorbed BMP-2 [0.98 microg per disc (control)]. Discs (n = 6 per group) were implanted subcutaneously in rats and retrieved at 7-day intervals over a period of 5 weeks for kinetic, histomorphometrical, morphological and histochemical analyses. RESULTS: In the incorporated-BMP-2 group, osteogenic activity was first observed 2 weeks after implantation and thereafter continued unabated until the end of the monitoring period. The net weekly rates of bone formation per disc were 5.8 mm3 at 2 weeks and 3.64 mm3 at 5 weeks. The total volumes of bone formed per disc at these junctures were 5.8 mm3 and 10.3 mm3, respectively. Bone tissue, which was formed by a direct ossification mechanism, was deposited at distances of up to 340 microm from the implant surfaces. The biomimetic coatings were degraded gradually, initially by foreign body giant cells alone and then also by osteoclasts. Forty percent of the coating material (and thus presumably of the incorporated BMP-2) remained at the end of the monitoring period. Hence, 60% of the incorporated BMP-2 had been released. At this 5-week juncture, no bone tissue was associated with any of the control implants. CONCLUSION: BMP-2 incorporated into biomimetic calcium phosphate coatings is capable not only of inducing bone formation at an ectopic site in vivo but also of doing so with a very high potency at a low pharmacological level, and of sustaining this activity for a considerable period of time. The sustainment of osteogenic activity is of great clinical importance for the osseointegration of dental and orthopedic implants.
Resumo:
We have previously shown that proteins can be incorporated into the latticework of calcium phosphate layers when biomimetically coprecipitated with the inorganic components, upon the surfaces of titanium-alloy implants. In the present study, we wished to ascertain whether recombinant human bone morphogenetic protein 2 (rhBMP-2) thus incorporated retained its bioactivity as an osteoinductive agent. Titanium alloy implants were coated biomimetically with a layer of calcium phosphate in the presence of different concentrations of rhBMP-2 (0.1-10 microg/mL). rhBMP-2 was successfully incorporated into the crystal latticework, as revealed by protein blot staining. rhBMP-2 was taken up by the calcium phosphate coatings in a dose-dependent manner, as determined by ELISA. Rat bone marrow stromal cells were grown directly on these coatings for 8 days. Their osteogenicity was then assessed quantitatively by monitoring alkaline phosphatase activity. This parameter increased as a function of rhBMP-2 concentrations within the coating medium. rhBMP-2 incorporated into calcium phosphate coatings was more potent in stimulating the alkaline phosphatase activity of the adhering cell layer than was the freely suspended drug in stimulating that of cell layers grown on a plastic substratum. This system may be of osteoinductive value in orthopedic and dental implant surgery.
Resumo:
PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.
Resumo:
One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.