224 resultados para Occlusion intestinale


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: We set out to investigate the predictors and time course for recanalization of spontaneous dissection of the cervical internal carotid artery (SICAD). METHODS: We prospectively included 249 consecutive patients (mean age, 45+/-11 years) with 268 SICAD. Ultrasound examinations were performed at presentation, during the first month, and then at 3, 6, and 12 months, and clinical follow-ups after 3, 6, and 12 months. RESULTS: Of 268 SICADs, 20 (7.5%) presented with occlusion. Antithrombotic treatment included anticoagulation in 174 (67%) patients, aspirin in 64 (24%) patients, and aspirin followed by anticoagulation or vice versa in 22 (8%) patients. Follow-up ultrasound showed normal findings in 160 (60%), occlusion in 51 (19%) vessels. The rate of complete recanalization was 16% at 1 month, 50% at 3 months, and 60% at 6 and 12 months. Initial occlusion of the dissected vessels reduced the odds of recanalization (OR, 4.0; 95% CI, 2.2-7.3; P<0.001), whereas the occurrence of local symptoms and signs only at presentation were independently associated with complete recanalization (OR, 0.4; 95% CI, 0.2-0.8; P=0.048). CONCLUSIONS: These results suggest that recanalization of SICAD occurs mainly within the first 6 months after the onset of symptoms. Initial occlusion reduces the likelihood of complete recanalization, whereas presentation with local symptoms and signs only increases it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To test the hypothesis that the National Institutes of Health Stroke Scale (NIHSS) score is associated with the findings of arteriography performed within the first hours after ischemic stroke. METHODS: We analyzed NIHSS scores on hospital admission and clinical and arteriographic findings of 226 consecutive patients (94 women, 132 men; mean age 62+/-12 years) who underwent arteriography within 6 hours of symptom onset in carotid stroke and within 12 hours in vertebrobasilar stroke. RESULTS: From stroke onset to hospital admission, 155+/-97 minutes elapsed, and from stroke onset to arteriography 245+/-100 minutes elapsed. Median NIHSS was 14 (range 3 to 38), and scores differed depending on the arteriographic findings (P<0.001). NIHSS scores in basilar, internal carotid, and middle cerebral artery M1 and M2 segment occlusions (central occlusions) were higher than in more peripherally located, nonvisible, or absent occlusions. Patients with NIHSS scores > or =10 had positive predictive values (PPVs) to show arterial occlusions in 97% of carotid and 96% of vertebrobasilar strokes. With an NIHSS score of > or =12, PPV to find a central occlusion was 91%. In a multivariate analysis, NIHSS subitems such as "level of consciousness questions," "gaze," "motor leg," and "neglect" were predictors of central occlusions. CONCLUSIONS: There is a significant association of NIHSS scores and the presence and location of a vessel occlusion. With an NIHSS score > or =10, a vessel occlusion will likely be seen on arteriography, and with a score > or =12, its location will probably be central.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Surgical treatment of renal artery aneurysms is inevitably associated with temporary renal artery occlusion and risk of ischemic injury. We present a technique for renal artery grafting and aneurysm exclusion without interrupting renal blood flow. REPORT: A symptomatic renal artery aneurysm was bypassed with a venous graft between the abdominal aorta and the very distal renal artery utilizing a distal anastomotic device without interruption of renal blood flow. The aneurysm was then excluded by means of hemostatic clips. CONCLUSION: The presented surgical technique offers the major advantage of avoiding organ ischemia and accelerating the surgical procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the case of a patient who presented with acute inferior myocardial infarction and embolic occlusion of the distal left anterior descending and proximal right coronary artery. A large atrial septal defect (ASD) was seen on transesophageal echocardiography and the ASD was closed during the same session as coronary angiography and percutaneous coronary intervention. The presence of embolic or thrombotic occlusions of coronary arteries should prompt interventional cardiologists to look for a patent foramen ovale or ASD and perform percutaneous closure right away.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Patients with refractory angina pectoris in end-stage coronary artery disease represent a severe condition with a higher reduction of life-expectancy and quality of life as compared to patients with stable coronary artery disease. It was the purpose of this study to invasively re-evaluate highly symptomatic patients with formerly diagnosed refractory angina pectoris in end-stage coronary artery disease for feasible options of myocardial revascularization. METHODS: Thirty-four patients formerly characterized as having end stage coronary artery disease with refractory angina pectoris were retrospectively followed for coronary interventions. RESULTS: Of those 34 patients 21 (61.8%) were eventually revascularized with percutaneous interventional revascularization (PCI). Due to complex coronary morphology (angulation, chronic total occlusion) PCI demanded an above-average amount of time (66 +/- 42 minutes, range 25-206 minutes) and materials (contrast media 247 +/- 209 ml, range 50-750 ml; PCI guiding wires 2.0 +/- 1.4, range 1-6 wires). Of PCI patients 7 (33.3%) showed a new lesion as a sign of progression of atherosclerosis. Clinical success rate with a reduction to angina class II or lower was 71.4% at 30 days. Surgery was performed in a total of8 (23.5%) patients with a clinical success rate of 62.5%. Based on an intention-to-treat 2 patients of originally 8 (25%) demonstrated clinical success. Mortality during follow-up (1-18 months) was 4.8% in patients who underwent PCI, 25% in patients treated surgically and 25% in those only treated medically. CONCLUSION: The majority of patients with end-stage coronary artery disease can be treated effectively with conventional invasive treatment modalities. Therefore even though it is challenging and demanding PCI should be considered as a first choice before experimental interventions are considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The efficacy of granulocyte colony-stimulating factor (G-CSF) for coronary collateral growth promotion and thus impending myocardial salvage has not been studied so far, to our best knowledge. METHODS AND RESULTS: In 52 patients with chronic stable coronary artery disease, age 62+/-11 years, the effect on a marker of myocardial infarct size (ECG ST segment elevation) and on quantitative collateral function during a 1-minute coronary balloon occlusion was tested in a randomized, placebo-controlled, double-blind fashion. The study protocol before coronary intervention consisted of occlusive surface and intracoronary lead ECG recording as well as collateral flow index (CFI, no unit) measurement in a stenotic and a > or =1 normal coronary artery before and after a 2-week period with subcutaneous G-CSF (10 microg/kg; n=26) or placebo (n=26). The CFI was determined by simultaneous measurement of mean aortic, distal coronary occlusive, and central venous pressure. The ECG ST segment elevation >0.1 mV disappeared significantly more often in response to G-CSF (11/53 vessels; 21%) than to placebo (0/55 vessels; P=0.0005), and simultaneously, CFI changed from 0.121+/-0.087 at baseline to 0.166+/-0.086 at follow-up in the G-CSF group, and from 0.152+/-0.082 to 0.131+/-0.071 in the placebo group (P<0.0001 for interaction of treatment and time). The absolute change in CFI from baseline to follow-up amounted to +0.049+/-0.062 in the G-CSF group and to -0.010+/-0.060 in the placebo group (P<0.0001). CONCLUSIONS: Subcutaneous G-CSF is efficacious during a short-term protocol in improving signs of myocardial salvage by coronary collateral growth promotion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The noble gas helium is devoid of anesthetic effects, and it elicits cardiac preconditioning. We hypothesized that inhalation of helium provides protection against postocclusive endothelial dysfunction after ischemia-reperfusion of the forearm in humans. METHODS: Eight healthy male subjects were enrolled in this study with a crossover design. Each volunteer was randomly exposed to 15 min of forearm ischemia in the presence or absence of helium inhalation. Helium was inhaled at an end-tidal concentration of 50 vol% from 15 min before ischemia until 5 min after the onset of reperfusion ("helium conditioning"). Hyperemic reaction, a marker of nitric oxide bioavailability and endothelial function, was determined at 15 and 30 min of reperfusion on the forearm using venous occlusion plethysmography. Expression of the proinflammatory markers CD11b, ICAM-1, PSGL-1, and L-selectin (CD62L) on leukocytes and P-selectin (CD62P), PSGL-1, and CD42b on platelets were measured by flow cytometry during reperfusion. RESULTS: Ischemia-reperfusion consistently reduced the postocclusive endothelium-dependent hyperemic reaction at 15 and 30 min of reperfusion. Periischemic inhalation of helium at 50 vol% did not improve postocclusive hyperemic reaction. Helium decreased expression of the proinflammatory marker CD11b and ICAM-1 on leukocytes and attenuated the expression of the procoagulant markers CD42b and PSGL-1 on platelets. CONCLUSIONS: Although inhalation of helium diminished the postischemic inflammatory reaction, our data indicate that human endothelium, which is a component of all vital organs, is not amenable to protection by helium at 50 vol% in vivo. This is in contrast to sevoflurane, which protects human endothelium at low subanesthetic concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eight premature infants ventilated for hyaline membrane disease and enrolled in the OSIRIS surfactant trial were studied. Lung mechanics, gas exchange [PaCO2, arterial/alveolar PO2 ratio (a/A ratio)], and ventilator settings were determined 20 minutes before and 20 minutes after the end of Exosurf instillation, and subsequently at 12-24 hour intervals. Respiratory system compliance (Crs) and resistance (Rrs) were measured by means of the single breath occlusion method. After surfactant instillation there were no significant immediate changes in PaCO2 (36 vs. 37 mmHg), a/A ratio (0.23 vs. 0.20), Crs (0.32 vs. 0.31 mL/cm H2O/kg), and Rrs (0.11 vs. 0.16 cmH2O/mL/s) (pooled data of 18 measurement pairs). During the clinical course, mean a/A ratio improved significantly each time from 0.17 (time 0) to 0.29 (time 12-13 hours), to 0.39 (time 24-36 hours) and to 0.60 (time 48-61 hours), although mean airway pressure was reduced substantially. Mean Crs increased significantly from 0.28 mL/cmH2O/kg (time 0) to 0.38 (time 12-13 hours), to 0.37 (time 24-38 hours), and to 0.52 (time 48-61 hours), whereas mean Rrs increased from 0.10 cm H2O/mL/s (time 0) to 0.11 (time 12-13 hours), to 0.13 (time 24-36 hours) and to (time 48-61 hours) with no overall significance. A highly significant correlation was found between Crs and a/A ratio (r = 0.698, P less than 0.001). We conclude that Exosurf does not induce immediate changes in oxygenation as does the instillation of (modified) natural surfactant preparations. However, after 12 and 24 hours of treatment oxygenation and Crs improve significantly.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The standard technique of two-dimensional intra-arterial digital subtraction angiography (2D-DSA) for the imaging of experimental rabbit aneurysms is invasive and has considerable surgical risks. Therefore, minimally invasive techniques ideally providing three-dimensional imaging for intervention planning and follow-up are needed. This study evaluates the feasibility and quality of three-dimensional 3-T magnetic resonance angiography (3D-3T-MRA) and compares 3D-3T-MRA with 2D-DSA in experimental aneurysms in the rabbit. METHOD: Three microsurgically created aneurysms in three rabbits were evaluated using 2D-DSA and 3D-3T-MRA. Imaging of the aneurysms was performed 2 weeks after creation using 2D-DSA and contrast-enhanced (CE) MRA. Measurements included aneurysm dome (length and width) and aneurysm neck. Aneurysm volumes were determined using CE-MRA. RESULTS: The measurements of the aneurysms' dimensions and the evaluation of vicinity vessels with both techniques showed a good correlation. The mean aneurysm length, aneurysm width and neck width measured with DSA (6.9, 4.1 and 2.8 mm, respectively) correlated with the measurements performed in 3D-3T-MRA (6.9, 4 and 2.5 mm, respectively). The mean aneurysm volumes measured with CE-MRA was 46.7 mm(3). CONCLUSION: 3D-3T CE-MRA is feasible and less invasive and is a safer imaging alternative to DSA for experimental aneurysm. Additionally, aneurysm technique this precise offers the possibility of repetitive 3D aneurysm volumetry for long-term follow-up studies after endovascular aneurysm occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS The aim of our study in patients with coronary artery disease (CAD) and present, or absent, myocardial ischaemia during coronary occlusion was to test whether (i) left ventricular (LV) filling pressure is influenced by the collateral circulation and, on the other hand, that (ii) its resistance to flow is directly associated with LV filling pressure. METHODS AND RESULTS In 50 patients with CAD, the following parameters were obtained before and during a 60 s balloon occlusion: LV, aortic (Pao) and coronary pressure (Poccl), flow velocity (Voccl), central venous pressure (CVP), and coronary flow velocity after coronary angioplasty (V(Ø-occl)). The following variables were determined and analysed at 10 s intervals during occlusion, and at 60 s of occlusion: LV end-diastolic pressure (LVEDP), velocity-derived (CFIv) and pressure-derived collateral flow index (CFIp), coronary collateral (Rcoll), and peripheral resistance index to flow (Rperiph). Patients with ECG signs of ischaemia during coronary occlusion (insufficient collaterals, n = 33) had higher values of LVEDP over the entire course of occlusion than those without ECG signs of ischaemia during occlusion (sufficient collaterals, n = 17). Despite no ischaemia in the latter, there was an increase in LVEDP from 20 to 60 s of occlusion. In patients with insufficient collaterals, CFIv decreased and CFIp increased during occlusion. Beyond an occlusive LVEDP > 27 mmHg, Rcoll and Rperiph increased as a function of LVEDP. CONCLUSION Recruitable collaterals are reciprocally tied to LV filling pressure during occlusion. If poorly developed, they affect it via myocardial ischaemia; if well grown, LV filling pressure still increases gradually during occlusion despite the absence of ischaemia indicating transmission of collateral perfusion pressure to the LV. With low, but not high, collateral flow, resistance to collateral as well as coronary peripheral flow is related to LV filling pressure in the high range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve. RESULTS 16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66). CONCLUSIONS Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.