201 resultados para METALLIC STENT
Resumo:
Background Among patients with acute ischemic stroke due to occlusions in the proximal anterior intracranial circulation, less than 40% regain functional independence when treated with intravenous tissue plasminogen activator (t-PA) alone. Thrombectomy with the use of a stent retriever, in addition to intravenous t-PA, increases reperfusion rates and may improve long-term functional outcome. Methods We randomly assigned eligible patients with stroke who were receiving or had received intravenous t-PA to continue with t-PA alone (control group) or to undergo endovascular thrombectomy with the use of a stent retriever within 6 hours after symptom onset (intervention group). Patients had confirmed occlusions in the proximal anterior intracranial circulation and an absence of large ischemic-core lesions. The primary outcome was the severity of global disability at 90 days, as assessed by means of the modified Rankin scale (with scores ranging from 0 [no symptoms] to 6 [death]). Results The study was stopped early because of efficacy. At 39 centers, 196 patients underwent randomization (98 patients in each group). In the intervention group, the median time from qualifying imaging to groin puncture was 57 minutes, and the rate of substantial reperfusion at the end of the procedure was 88%. Thrombectomy with the stent retriever plus intravenous t-PA reduced disability at 90 days over the entire range of scores on the modified Rankin scale (P<0.001). The rate of functional independence (modified Rankin scale score, 0 to 2) was higher in the intervention group than in the control group (60% vs. 35%, P<0.001). There were no significant between-group differences in 90-day mortality (9% vs. 12%, P=0.50) or symptomatic intracranial hemorrhage (0% vs. 3%, P=0.12). Conclusions In patients receiving intravenous t-PA for acute ischemic stroke due to occlusions in the proximal anterior intracranial circulation, thrombectomy with a stent retriever within 6 hours after onset improved functional outcomes at 90 days.
Resumo:
PURPOSE To investigate the 2-year technical and clinical results of primary nitinol stent placement in comparison with percutaneous transluminal angioplasty (PTA) in the treatment of de novo lesions of the popliteal artery. METHODS The ETAP study (Endovascular Treatment of Atherosclerotic Popliteal Artery Lesions: balloon angioplasty vs. primary stenting; www.ClinicalTrials.gov identifier NCT00712309) is a prospective, randomized trial that enrolled 246 patients (158 men; mean age 72 years) who were randomly assigned to receive a nitinol stent (n=119) or PTA (n=127) for lesions averaging 42.3 mm in length. The results of the primary study endpoint were published. Secondary outcome measures and endpoints included primary patency (freedom from duplex-detected target lesion restenosis), target lesion revascularization (TLR), secondary patency, changes in ankle-brachial index and Rutherford class, and event-free survival (freedom from target limb amputation, TLR, myocardial infarction, and death). RESULTS In total, 183 patients (89 stent and 94 PTA) were available for the 2-year analysis. The primary patency rate was significantly higher in the stent group (64.2%) than in the PTA group (31.3%, p=0.0001). TLR rates were 22.4% and 59.5%, respectively (p=0.0001). When provisional stent placement in the PTA arm was not considered as TLR and loss in patency, the differences prevailed between the study groups but were not significant (64.2% vs. 56.1% for primary patency, respectively; p=0.44). A significant improvement in ABI and Rutherford category was observed at 2 years in both groups. CONCLUSION In treatment of obstructive popliteal artery lesions, provisional stenting reveals equivalent patency in comparison to primary stenting. However, the 2-year results of this trial suggest the possibility of a shift toward higher patency rates in favor of primary stenting.
Resumo:
INTRODUCTION Diagnostic tools to show emboli reliably and protection techniques against embolization when employing stent retrievers are necessary to improve endovascular stroke therapy. The aim of the present study was to investigate iatrogenic emboli using susceptibility-weighted imaging (SWI) in an open series of patients who had been treated with stent retriever thrombectomy using emboli protection techniques. METHODS Patients with anterior circulation stroke examined with MRI before and after stent retriever thrombectomy were assessed for iatrogenic embolic events. Thrombectomy was performed in flow arrest and under aspiration using a balloon-mounted guiding catheter, a distal access catheter, or both. RESULTS In 13 of 57 patients (22.8 %) post-interventional SWI sequences detected 16 microemboli. Three of them were associated with small ischemic lesions on diffusion-weighted imaging (DWI). None of the microemboli were located in a new vascular territory, none showed clinical signs, and all 13 patients have been rated as Thrombolysis in Cerebral Infarction (TICI) 2b (n = 3) or 3 (n = 10). Retrospective reevaluation of the digital subtraction angiography (DSA) detected discrete flow stagnation nearby the iatrogenic microemboli in four patients with a positive persistent collateral sign in one. CONCLUSION Our study demonstrates two things: First, SWI seems to be more sensitive to detect emboli than DWI and DSA and, second, proximal or distal protected stent retriever thrombectomy seems to prevent iatrogenic embolization into new vascular territories during retraction of the thrombus, but not downstream during mobilization of the thrombus. Both techniques should be investigated and refined further.
Resumo:
BACKGROUND Percutaneous coronary intervention (PCI) with drug-eluting stents is the standard of care for treatment of native coronary artery stenoses, but optimum treatment strategies for bare metal stent and drug-eluting stent in-stent restenosis (ISR) have not been established. We aimed to compare and rank percutaneous treatment strategies for ISR. METHODS We did a network meta-analysis to synthesise both direct and indirect evidence from relevant trials. We searched PubMed, the Cochrane Library Central Register of Controlled Trials, and Embase for randomised controlled trials published up to Oct 31, 2014, of different PCI strategies for treatment of any type of coronary ISR. The primary outcome was percent diameter stenosis at angiographic follow-up. This study is registered with PROSPERO, number CRD42014014191. FINDINGS We deemed 27 trials eligible, including 5923 patients, with follow-up ranging from 6 months to 60 months after the index intervention. Angiographic follow-up was available for 4975 (84%) of 5923 patients 6-12 months after the intervention. PCI with everolimus-eluting stents was the most effective treatment for percent diameter stenosis, with a difference of -9·0% (95% CI -15·8 to -2·2) versus drug-coated balloons (DCB), -9·4% (-17·4 to -1·4) versus sirolimus-eluting stents, -10·2% (-18·4 to -2·0) versus paclitaxel-eluting stents, -19·2% (-28·2 to -10·4) versus vascular brachytherapy, -23·4% (-36·2 to -10·8) versus bare metal stents, -24·2% (-32·2 to -16·4) versus balloon angioplasty, and -31·8% (-44·8 to -18·6) versus rotablation. DCB were ranked as the second most effective treatment, but without significant differences from sirolimus-eluting (-0·2% [95% CI -6·2 to 5·6]) or paclitaxel-eluting (-1·2% [-6·4 to 4·2]) stents. INTERPRETATION These findings suggest that two strategies should be considered for treatment of any type of coronary ISR: PCI with everolimus-eluting stents because of the best angiographic and clinical outcomes, and DCB because of its ability to provide favourable results without adding a new stent layer. FUNDING None.
Resumo:
Nitinol stent oversizing is frequently performed in peripheral arteries to ensure a desirable lumen gain. However, the clinical effect of mis-sizing remains controversial. The goal of this study was to provide a better understanding of the structural and hemodynamic effects of Nitinol stent oversizing. Five patient-specific numerical models of non-calcified popliteal arteries were developed to simulate the deployment of Nitinol stents with oversizing ratios ranging from 1.1 to 1.8. In addition to arterial biomechanics, computational fluid dynamics methods were adopted to simulate the physiological blood flow inside the stented arteries. Results showed that stent oversizing led to a limited increase in the acute lumen gain, albeit at the cost of a significant increase in arterial wall stresses. Furthermore, localized areas affected by low Wall Shear Stress increased with higher oversizing ratios. Stents were also negatively impacted by the procedure as their fatigue safety factors gradually decreased with oversizing. These adverse effects to both the artery walls and stents may create circumstances for restenosis. Although the ideal oversizing ratio is stent-specific, this study showed that Nitinol stent oversizing has a very small impact on the immediate lumen gain, which contradicts the clinical motivations of the procedure.
Resumo:
AIMS The GLOBAL LEADERS trial is a superiority study in patients undergoing percutaneous coronary intervention, with a uniform use of Biolimus A9-eluting stents (BES) and bivalirudin. GLOBAL LEADERS was designed to assess whether a 24-month antithrombotic regimen with ticagrelor and one month of acetylsalicylic acid (ASA), compared to conventional dual antiplatelet therapy (DAPT), improves outcomes. METHODS AND RESULTS Patients (n >16,000) are randomised (1:1 ratio) to ticagrelor 90 mg twice daily for 24 months plus ASA ≤100 mg for one month versus DAPT with either ticagrelor (acute coronary syndrome) or clopidogrel (stable coronary artery disease) for 12 months plus ASA ≤100 mg for 24 months. The primary outcome is a composite of all-cause mortality or non-fatal, new Q-wave myocardial infarction at 24 months. The key safety endpoint is investigator-reported class 3 or 5 bleeding according to the Bleeding Academic Research Consortium (BARC) definitions. Sensitivity analysis will be carried out to explore potential differences in outcome across geographic regions and according to specific angiographic and clinical risk estimates. CONCLUSIONS The GLOBAL LEADERS trial aims to assess the role of ticagrelor as a single antiplatelet agent after a short course of DAPT for the long-term prevention of cardiac adverse events, across a wide spectrum of patients, following BES implantation.
Resumo:
OBJECTIVES This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. BACKGROUND Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. METHODS Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. RESULTS Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). CONCLUSIONS DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938).
Resumo:
AIMS Newer-generation drug-eluting stents (DES) have been shown to be superior to first-generation DES. Current-generation DES have zotarolimus, everolimus or biolimus as antiproliferative drugs. Novolimus, a metabolite of sirolimus, has been specifically developed to provide efficacy similar to currently available agents at a lower dose and thus requires a lower polymer load. We report the final five-year outcomes of the EXCELLA II trial comparing a zotarolimus-eluting stent (ZES) with a novolimus-eluting stent (NES). METHODS AND RESULTS EXCELLA II is a prospective, multicentre, single-blind, non-inferiority clinical trial. Patients (n=210) with a maximum of two de novo lesions in two different epicardial vessels were randomised (2:1) to treatment with either NES (n=139) or ZES (n=71). At five-year follow-up, patients in the NES group had a significantly lower incidence of the patient-oriented (HR 0.53, 95% CI: 0.32-0.87, p=0.013) and device-oriented (HR 0.38, 95% CI: 0.17-0.83, p=0.011) composite endpoints. There was no difference in cardiac death and definite/probable stent thrombosis between the two groups; however, there was a trend towards reduction in myocardial infarction and repeat revascularisation in the NES group at five-year follow-up. CONCLUSIONS At five-year follow-up, the incidence of device- and patient-oriented events was significantly lower in the NES group. Further studies, adequately powered for clinical outcomes, are warranted. TRIAL REGISTRATION ClinicalTrials.gov number NCT00792753.
Resumo:
BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.
Resumo:
OBJECTIVES To assess the clinical profile and long-term mortality in SYNTAX score II based strata of patients who received percutaneous coronary interventions (PCI) in contemporary randomized trials. BACKGROUND The SYNTAX score II was developed in the randomized, all-comers' SYNTAX trial population and is composed by 2 anatomical and 6 clinical variables. The interaction of these variables with the treatment provides individual long-term mortality predictions if a patient undergoes coronary artery bypass grafting (CABG) or PCI. METHODS Patient-level (n=5433) data from 7 contemporary coronary drug-eluting stent (DES) trials were pooled. The mortality for CABG or PCI was estimated for every patient. The difference in mortality estimates for these two revascularization strategies was used to divide the patients into three groups of theoretical treatment recommendations: PCI, CABG or PCI/CABG (the latter means equipoise between CABG and PCI for long term mortality). RESULTS The three groups had marked differences in their baseline characteristics. According to the predicted risk differences, 5115 patients could be treated either by PCI or CABG, 271 should be treated only by PCI and, rarely, CABG (n=47) was recommended. At 3-year follow-up, according to the SYNTAX score II recommendations, patients recommended for CABG had higher mortality compared to the PCI and PCI/CABG groups (17.4%; 6.1% and 5.3%, respectively; P<0.01). CONCLUSIONS The SYNTAX score II demonstrated capability to help in stratifying PCI procedures.