217 resultados para dose escalation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The γ-aminobutyric acid (GABA) system has been proposed as a target for novel antidepressant and anxiolytic treatments. Emerging evidence suggests that gabapentin (GBP), an anticonvulsant drug that significantly increases brain GABA levels, is effective in the treatment of anxiety disorders. The current study was designed to measure prefrontal and occipital GABA levels in medication-free healthy subjects after taking 0 mg, 150 mg and 300 mg GBP. Subjects were scanned on a 3T scanner using a transmit-receive head coil that provided a relatively homogenous radiofrequency field to obtain spectroscopy measurement in the medial prefrontal (MPFC) and occipital cortex (OCC). There was no dose-dependent effect of GBP on GABA levels in the OCC or MPFC. There was also no effect on Glx, choline or N-acetyl-aspartate concentrations. The previously reported finding of increased GABA levels after GBP treatment is not evident for healthy subjects at the dose of 150 and 300 mg. As a result, if subjects are scanned on a 3T scanner, low dose GPB is not useful as an experimental challenge agent on the GABA system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salvage radiation therapy is the sole curative treatment for patients experiencing biochemical relapse after radical surgical treatment of prostate cancer. The main dilemma in salvage radiation therapy is, whether or not biochemical relapse represents purely localized recurrent disease in the prostatic fossa or systemic micrometastasis. Initiating salvage radiation therapy at an early time point raises its chances of success, but may lead to overtreatment of patients. Target volume definition and treatment techniques are a matter of current research, with still many questions unanswered. Strategies of treatment escalation either by increasing the treatment dose or combining radiation therapy with androgen deprivation therapy are being addressed in clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: We compare the dose parameters between 3 different radiosurgery delivery techniques which may have an impact on cochlea function. Methods: Five patients with unilateral vestibular schwannoma (VS) were selected for this study. Planning procedure was carried out using the BrainLAB® iPlan planning system v. 4.5. For each patient three different planning techniques were used: dynamic arc (DA) with 5 arcs per plan, hybrid arc (HA) with 5 arcs per plan and IMRT with 8 fields per plan. For each technique, two plans were generated with different methods: with the first method (PTV coverage) it was the goal to fully cover the PTV with at least 12 Gy (normalization: 12 Gy covered 99% of the PTV) and with the second method (cochlea sparing) it was the goal to spare the cochlea (normalization: 12 Gy covers 50% of the PTV/V4Gy of cochlea lower than 1%). Plan evaluation was done considering target volume and coverage (conformity and homogeneity) and OAR constraints (mean (Dmean) and maximum dose (Dmax) to cochlea, Dmax to brainstem and cochlea). The total number of monitor units (MU) was analyzed. Results: The median tumor volume was 0.95 cm³ (range, 0.86-3 cm³). The median PTV was 1.44 cm³ (range, 1-3.5 cm³). The median distance between the tumor and the cochlea's modiulus was 2.7 mm (range, 1.8-6.3 mm). For the PTV coverage method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.872) and in Dmean (p= 0.860). We found a significant correlation (p< 0.05) between the target volume and the cochlear Dmean for all plans with Pearson's coefficient correlation of 0.90, 0.92 and 0.94 for the DA, HA and IMRT techniques, respectively. For the cochlea sparing method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.310) and in Dmean (p= 0.275). However, in this group the V4Gy of the ipsilateral cochlea represents less than 1%. When using the HA or IMRT technique, the homogeneity and conformity in the PTV, but also the number of MUs were increased in comparison to the DA technique. Conclusion: VS tumors that extend distally into the IAC had an equivalent sparing of cochlea with DA approach compared with the HA and IMRT techniques. Disclosure: No significant relationships.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To compare the computed tomography (CT) dose and image quality with the filtered back projection against the iterative reconstruction and CT with a minimal electronic noise detector. METHODS A lung phantom (Chest Phantom N1 by Kyoto Kagaku) was scanned with 3 different CT scanners: the Somatom Sensation, the Definition Flash and the Definition Edge (all from Siemens, Erlangen, Germany). The scan parameters were identical to the Siemens presetting for THORAX ROUTINE (scan length 35 cm and FOV 33 cm). Nine different exposition levels were examined (reference mAs/peek voltage): 100/120, 100/100, 100/80, 50/120, 50/100, 50/80, 25/120, 25/100 and 25 mAs/80 kVp. Images from the SOMATOM Sensation were reconstructed using classic filtered back projection. Iterative reconstruction (SAFIRE, level 3) was performed for the two other scanners. A Stellar detector was used with the Somatom Definition Edge. The CT doses were represented by the dose length products (DLPs) (mGycm) provided by the scanners. Signal, contrast, noise and subjective image quality were recorded by two different radiologists with 10 and 3 years of experience in chest CT radiology. To determine the average dose reduction between two scanners, the integral of the dose difference was calculated from the lowest to the highest noise level. RESULTS When using iterative reconstruction (IR) instead of filtered back projection (FBP), the average dose reduction was 30%, 52% and 80% for bone, soft tissue and air, respectively, for the same image quality (P < 0.0001). The recently introduced Stellar detector (Sd) lowered the radiation dose by an additional 27%, 54% and 70% for bone, soft tissue and air, respectively (P < 0.0001). The benefit of dose reduction was larger at lower dose levels. With the same radiation dose, an average of 34% (22%-37%) and 25% (13%-46%) more contrast to noise was achieved by changing from FBP to IR and from IR to Sd, respectively. For the same contrast to noise level, an average of 59% (46%-71%) and 51% (38%-68%) dose reduction was produced for IR and Sd, respectively. For the same subjective image quality, the dose could be reduced by 25% (2%-42%) and 44% (33%-54%) using IR and Sd, respectively. CONCLUSION This study showed an average dose reduction between 27% and 70% for the new Stellar detector, which is equivalent to using IR instead of FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. METHODS AND RESULTS Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m(2) (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. CONCLUSION A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with ilio-femoral deep-vein thrombosis (DVT) are at high risk of developing the post-thrombotic syndrome (PTS). In comparison to anticoagulation therapy alone, extended venography-guided catheter-directed thrombolysis without routine stenting of venous stenosis in patients with ilio-femoral DVT is associated with an increased risk of bleeding and a moderate reduction of PTS. We performed a prospective single-centre study to investigate safety, patency and incidence of PTS in patients with acute ilio-femoral DVT treated with fixed-dose ultrasound-assisted catheter-directed thrombolysis (USAT; 20 mg rt-PA during 15 hours) followed by routing stenting of venous stenosis, defined as residual luminal narrowing >50%, absent antegrade flow, or presence of collateral flow at the site of suspected stenosis. A total of 87 patients (age 46 ± 21 years, 60% women) were included. At 15 hours, thrombolysis success ≥50% was achieved in 67 (77%) patients. Venous stenting (mean 1.9 ± 1.3 stents) was performed in 70 (80%) patients, with the common iliac vein as the most frequent stenting site (83%). One major (1%; 95% CI, 0-6%) and 6 minor bleedings (7%; 95%CI, 3-14%) occurred. Primary and secondary patency rates at 1 year were 87% (95% CI, 74-94%) and 96% (95% CI, 88-99%), respectively. At three months, 88% (95% CI, 78-94%) of patients were free from PTS according to the Villalta scale, with a similar rate at one year (94%, 95% CI, 81-99%). In conclusion, a fixed-dose USAT regimen followed by routine stenting of underlying venous stenosis in patients with ilio-femoral DVT was associated with a low bleeding rate, high patency rates, and a low incidence of PTS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. MATERIALS AND METHODS 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. RESULTS In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP. CONCLUSION iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Albeit clear advances in the treatment of SLE, many patients still present with refractory lupus nephritis requiring new treatment strategies for this disease. Here we determined whether reduced doses of the topoisomerase I inhibitor irinotecan, which is known as chemotherapeutic agent, were able to suppress SLE in NZB/W F1 mice. We further evaluated the potential mechanism how irinotecan influenced the course of SLE. Methods NZB/W F1 mice were treated with low dose irinotecan either from week 24 of age or from established glomerulonephritis defined by a proteinuria ≥grade 3+. Binding of anti-dsDNA antibodies was measured by ELISA; and DNA relaxation was visualized by gel electrophoresis. Results Significantly reduced irinotecan dosages improved lupus nephritis and prolonged survival in NZB/W F1 mice. The lowest dose successfully used for the treatment of established murine lupus nephritis was more than 50 times lower than the dose usually applied for chemotherapy in humans. As a mechanism, low dose irinotecan reduced B cell activity; however, the levels of B cell activity in irinotecan-treated mice were similar to those in Balb/c mice of the same age suggesting that irinotecan did not induce a clear immunosuppression. In addition, incubation of double-stranded (ds) DNA with topoisomerase I increased binding of murine and human anti-dsDNA antibodies showing for the first time that relaxed DNA is more susceptible to anti-dsDNA antibody binding. This effect was reversed by addition of the topoisomerase I inhibitor camptothecin. Conclusion Our results propose topoisomerase I inhibitors as a novel and targeted therapy for SLE. © 2014 American College of Rheumatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dose-response strategy may not only allow investigation of the impact of foods and nutrients on human health but may also reveal differences in the response of individuals to food ingestion based on their metabolic health status. In a randomized crossover study, we challenged 19 normal-weight (BMI: 20-25 kg/m(2)) and 18 obese (BMI: >30 kg/m(2)) men with 500, 1000, and 1500 kcal of a high-fat (HF) meal (60.5% energy from fat). Blood was taken at baseline and up to 6 h postprandially and analyzed for a range of metabolic, inflammatory, and hormonal variables, including plasma glucose, lipids, and C-reactive protein and serum insulin, glucagon-like peptide-1, interleukin-6 (IL-6), and endotoxin. Insulin was the only variable that could differentiate the postprandial response of normal-weight and obese participants at each of the 3 caloric doses. A significant response of the inflammatory marker IL-6 was only observed in the obese group after ingestion of the HF meal containing 1500 kcal [net incremental AUC (net iAUC) = 22.9 ± 6.8 pg/mL × 6 h, P = 0.002]. Furthermore, the net iAUC for triglycerides significantly increased from the 1000 to the 1500 kcal meal in the obese group (5.0 ± 0.5 mmol/L × 6 h vs. 6.0 ± 0.5 mmol/L × 6 h, P = 0.015) but not in the normal-weight group (4.3 ± 0.5 mmol/L × 6 h vs. 4.8 ± 0.5 mmol/L × 6 h, P = 0.31). We propose that caloric dose-response studies may contribute to a better understanding of the metabolic impact of food on the human organism. This study was registered at clinicaltrials.gov as NCT01446068.