180 resultados para Topography guided photorefractive keratectomy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Infiltration procedures are a common treatment of lumbar radiculopathy. There is a wide variety of infiltration techniques without an established gold standard. Therefore, we compared the effectiveness of CT-guided transforaminal infiltrations versus anatomical landmark-guided transforaminal infiltrations at the lower lumbar spine in case of acute sciatica at L3-L5. METHODS A retrospective chart review was conducted of 107 outpatients treated between 2009 and 2011. All patients were diagnosed with lumbar radiculopathic pain secondary to disc herniation in L3-L5. A total of 52 patients received CT-guided transforaminal infiltrations; 55 patients received non-imaging-guided nerve root infiltrations. The therapeutic success was evaluated regarding number of physician contacts, duration of treatment, type of analgesics used and loss of work days. Defined endpoint was surgery at the lower lumbar spine. RESULTS In the CT group, patients needed significantly less oral analgesics (p < 0.001). Overall treatment duration and physician contacts were significantly lower in the CT group (p < 0.001 and 0.002) either. In the CT group, patients lost significant fewer work days due to incapacity (p < 0.001). Surgery had to be performed in 18.2 % of the non-imaging group patients (CT group: 1.9 %; p = 0.008). CONCLUSION This study shows that CT-guided periradicular infiltration in lumbosciatica caused by intervertebral disc herniation is significantly superior to non-imaging, anatomical landmark-guided infiltration, regarding the parameters investigated. The high number of treatment failures in the non-imaging group underlines the inferiority of this treatment concept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymorbid patients, diverse diagnostic and therapeutic options, more complex hospital structures, financial incentives, benchmarking, as well as perceptional and societal changes put pressure on medical doctors, specifically if medical errors surface. This is particularly true for the emergency department setting, where patients face delayed or erroneous initial diagnostic or therapeutic measures and costly hospital stays due to sub-optimal triage. A "biomarker" is any laboratory tool with the potential better to detect and characterise diseases, to simplify complex clinical algorithms and to improve clinical problem solving in routine care. They must be embedded in clinical algorithms to complement and not replace basic medical skills. Unselected ordering of laboratory tests and shortcomings in test performance and interpretation contribute to diagnostic errors. Test results may be ambiguous with false positive or false negative results and generate unnecessary harm and costs. Laboratory tests should only be ordered, if results have clinical consequences. In studies, we must move beyond the observational reporting and meta-analysing of diagnostic accuracies for biomarkers. Instead, specific cut-off ranges should be proposed and intervention studies conducted to prove outcome relevant impacts on patient care. The focus of this review is to exemplify the appropriate use of selected laboratory tests in the emergency setting for which randomised-controlled intervention studies have proven clinical benefit. Herein, we focus on initial patient triage and allocation of treatment opportunities in patients with cardiorespiratory diseases in the emergency department. The following five biomarkers will be discussed: proadrenomedullin for prognostic triage assessment and site-of-care decisions, cardiac troponin for acute myocardial infarction, natriuretic peptides for acute heart failure, D-dimers for venous thromboembolism, C-reactive protein as a marker of inflammation, and procalcitonin for antibiotic stewardship in infections of the respiratory tract and sepsis. For these markers we provide an overview on physiopathology, historical evolution of evidence, strengths and limitations for a rational implementation into clinical algorithms. We critically discuss results from key intervention trials that led to their use in clinical routine and potential future indications. The rational for the use of all these biomarkers, first, tackle diagnostic ambiguity and consecutive defensive medicine, second, delayed and sub-optimal therapeutic decisions, and third, prognostic uncertainty with misguided triage and site-of-care decisions all contributing to the waste of our limited health care resources. A multifaceted approach for a more targeted management of medical patients from emergency admission to discharge including biomarkers, will translate into better resource use, shorter length of hospital stay, reduced overall costs, improved patients satisfaction and outcomes in terms of mortality and re-hospitalisation. Hopefully, the concepts outlined in this review will help the reader to improve their diagnostic skills and become more parsimonious laboratory test requesters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Successful repair of defects in the avascular zone of meniscus remains a challenge in orthopedics. This proof of concept study aimed to investigate a guided tissue regeneration approach for treatment of tears in meniscus avascular zone in a goat model. DESIGN Full-depth longitudinal tear was created in the avascular zone of the meniscus and sutured. In the two treatment groups, porcine collagen membrane was wrapped around the tear without (CM) or with injection of expanded autologous chondrocytes (CM+cells), whereas in the control group the tear remained only sutured. Gait recovery was evaluated during the entire follow-up period. On explantation at 3 and 6 months, macroscopic gross inspection assessed healing of tears, degradation of collagen membrane, potential signs of inflammation, and osteoarthritic changes. Microscopic histology scoring criteria were developed to evaluate healing of tears, the cellular response, and the inflammatory response. RESULTS Gait recovery suggested protective effect of collagen membrane and was supported by macroscopical evaluation where improved tear healing was noted in both treated groups. Histology scoring in CM compared to suture group revealed an increase in tear margins contact, newly formed connective tissue between margins, and cell formations surrounded with new matrix after 3 months yet not maintained after 6 months. In contrast, in the CM+cells group these features were observed after 3 and 6 months. CONCLUSIONS A transient, short-term guided tissue regeneration of avascular meniscal tears occurred upon application of collagen membrane, whereas addition of expanded autologous chondrocytes supported more sustainable longer term tear healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To associate the dimension of the facial bone wall with clinical, radiological, and patient-centered outcomes at least 10 years after immediate implant placement with simultaneous guided bone regeneration in a retrospective study. MATERIAL AND METHODS Primary endpoint was the distance from the implant shoulder (IS) to the first bone-to-implant contact (IS-BIC10y ). Secondary endpoints included the facial bone thickness (BT10y ) 2, 4, and 6 mm apical to the IS, and the implant position. At baseline, the horizontal defect width (HDWBL ) from the implant surface to the alveolar wall was recorded. At recall, distance from the IS to the mucosal margin (IS-MM10y ), degree of soft tissue coverage of the mesial and distal aspects of the implants (PISm10y , PISd10y ; Papilla Index), pocket probing depth (PPD10y ), and patient-centered outcomes were determined. Width of the keratinized mucosa (KM), Full-Mouth Plaque and Bleeding Score (FMPS, FMBS) were available for both time points. RESULTS Of the 20 patients who underwent immediate implant placement with simultaneous guided bone regeneration and transmucosal healing, nine males and eight females with a median age of 62 years (42 min, 84 max) were followed up for a median period of 10.5 y (min 10.1 max 11.5). The 10-year implant survival rate was 100%. Multivariate regression analysis revealed a correlation of the IS-BIC10y , controlled for age and gender, with four parameters: HDWBL (P = 0.03), KMBL -10 (P = 0.02), BT10 4 mm (P = 0.01), and BT10 6 mm (P = 0.01). CONCLUSION Within the conditions of the present study, the horizontal defect width was the main indicator for the vertical dimension of the facial bone. The facial bone dimension was further associated with a reduction in the width of the keratinized mucosa and the dimension of the buccal bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pencil beam scanned (PBS) proton therapy has many advantages over conventional radiotherapy, but its effectiveness for treating mobile tumours remains questionable. Gating dose delivery to the breathing pattern is a well-developed method in conventional radiotherapy for mitigating tumour-motion, but its clinical efficiency for PBS proton therapy is not yet well documented. In this study, the dosimetric benefits and the treatment efficiency of beam gating for PBS proton therapy has been comprehensively evaluated. A series of dedicated 4D dose calculations (4DDC) have been performed on 9 different 4DCT(MRI) liver data sets, which give realistic 4DCT extracting motion information from 4DMRI. The value of 4DCT(MRI) is its capability of providing not only patient geometries and deformable breathing characteristics, but also includes variations in the breathing patterns between breathing cycles. In order to monitor target motion and derive a gating signal, we simulate time-resolved beams' eye view (BEV) x-ray images as an online motion surrogate. 4DDCs have been performed using three amplitude-based gating window sizes (10/5/3 mm) with motion surrogates derived from either pre-implanted fiducial markers or the diaphragm. In addition, gating has also been simulated in combination with up to 19 times rescanning using either volumetric or layered approaches. The quality of the resulting 4DDC plans has been quantified in terms of the plan homogeneity index (HI), total treatment time and duty cycle. Results show that neither beam gating nor rescanning alone can fully retrieve the plan homogeneity of the static reference plan. Especially for variable breathing patterns, reductions of the effective duty cycle to as low as 10% have been observed with the smallest gating rescanning window (3 mm), implying that gating on its own for such cases would result in much longer treatment times. In addition, when rescanning is applied on its own, large differences between volumetric and layered rescanning have been observed as a function of increasing number of re-scans. However, once gating and rescanning is combined, HI to within 2% of the static plan could be achieved in the clinical target volume, with only moderately prolonged treatment times, irrespective of the rescanning strategy used. Moreover, these results are independent of the motion surrogate used. In conclusion, our results suggest image guided beam gating, combined with rescanning, is a feasible, effective and efficient motion mitigation approach for PBS-based liver tumour treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to compare orthodromic sural nerve conduction study (NCS) results using ultrasound-guided needle positioning (USNP) to surface electrode recordings. METHODS 51 healthy subjects aged 24 - 80 years, divided into 5 age groups, were examined. Electrical stimuli were applied behind the lateral malleolus. Sensory nerve action potentials (SNAPs) were recorded 8 and 15 cm proximally with surface and needle electrodes. RESULTS Mean SNAP amplitudes in µV (surface/needle electrodes) averaged 12.7 (SD 7.6)/40.6 (SD 20.8), P<0.001, for subjects aged 20-29 years, and 5.0 (SD 2.4)/19.8 (SD 9.8), P<0.01, for subjects aged > 60 years. SNAP amplitudes were smaller at the proximal recording location. DISCUSSION NCS using USNP yield higher amplitude responses than surface electrodes in all age groups at all recording sites. SNAP amplitudes are smaller at proximal recording locations due to sural nerve branching. This article is protected by copyright. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ciliates have evolved highly complex and intricately controlled pathways to ensure the precise and complete removal of all genomic sequences not required for vegetative growth. At the same time, they retain a reference copy of all their genetic information for future generations. This chapter describes how different ciliates use RNA-mediated DNA comparison processes to form new somatic nuclei from germline nuclei. While these processes vary in their precise mechanisms, they all use RNA to target genomic DNA sequences—either for retention or elimination. They also all consist of more than one individual pathway acting cooperatively—the two subsets of small RNAs in Paramecium and the guide RNAs and Piwi-interacting RNAs in Oxytricha—to ensure a strong belt-and-braces approach to consistent and precise somatic nucleus development. Nonetheless, this genome comparison approach to somatic nucleus development provides an elegant method for trans-generational environmental adaptation. Conceptually, it is easy to imagine how somatic changes that occur during vegetative growth could be transferred to meiotic offspring, while an unaltered germline genome is retained. Further research in this area will have far-reaching implications for the trans-generational adaptation of more distantly related eukaryotes, such as humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Image-guided systems have recently been introduced for their application in liver surgery.We aimed to identify and propose suitable indications for image-guided navigation systems in the domain of open oncologic liver surgery and,more specifically, in the setting of liver resection with and without microwave ablation. Method Retrospective analysis was conducted in patients undergoing liver resection with and without microwave ablation using an intraoperative image-guided stereotactic system during three stages of technological development (accuracy: 8.4 ± 4.4 mm in phase I and 8.4 ± 6.5 mm in phase II versus 4.5 ± 3.6 mm in phase III). It was evaluated, in which indications image-guided surgery was used according to the different stages of technical development. Results Between 2009 and 2013, 65 patients underwent image-guided surgical treatment, resection alone (n=38), ablation alone (n =11), or a combination thereof (n =16). With increasing accuracy of the system, image guidance was progressively used for atypical resections and combined microwave ablation and resection instead of formal liver resection (p<0.0001). Conclusion Clinical application of image guidance is feasible, while its efficacy is subject to accuracy. The concept of image guidance has been shown to be increasingly efficient for selected indications in liver surgery. While accuracy of available technology is increasing pertaining to technological advancements, more and more previously untreatable scenarios such as multiple small, bilobar lesions and so-called vanishing lesions come within reach.