246 resultados para Subaortic Stenosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The incidence of coronary artery disease (CAD) in totally asymptomatic patients with myocardial ischemia during stress testing is unknown. METHODS: 54 patients with asymptomatic myocardial ischemia participated in the Swiss Interventional Study on Silent Ischemia type I (SWISSI I). Asymptomatic myocardial ischemia was verified by bicycle ergometry and stress imaging (echocardiography or scintigraphy). Findings from coronary angiographies in the course of the study constituted the main outcome. RESULTS: Of the 54 study participants, 29 patients (53.7%) underwent coronary angiography. CAD was found in 27 of 29 patients (93.1%). In those 27 patients with CAD, 9 patients (33.3%) suffered from single vessel disease, 9 patients (33.3%) from two vessel disease, and 9 patients (33.3%) from triple vessel disease. Two patients showed left main coronary artery stenosis. CONCLUSION: This study shows a high incidence of relevant CAD among totally asymptomatic patients with myocardial ischemia during stress testing. Previously healthy subjects with exercise-induced ST-segment depression at check-up examinations, even if asymptomatic, should have further diagnostic evaluation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to evaluate ECG-gated whole chest CTA as a routine triage tool for patients with acute chest pain. MATERIAL AND METHODS: Whole chest CTA with retrospective ECG-gating was performed in 30 patients with acute atypical chest pain. The ten main segments of the coronary arteries, the pulmonary arteries, the aorta, and the myocardium (function, morphology) were independently analyzed by a resident and two senior radiologists. The inter-observer agreement between resident and senior radiologists was calculated. A final diagnosis was determined by consensus. RESULTS: Thirty patients were included. The coronary artery segments, myocardium and pulmonary arteries were considered analyzable in 84%, 90% and 97% of cases respectively. A final diagnosis for the cause of pain was retained in 19 patients: significant coronary artery stenosis (5), pulmonary embolus (5), aortic dissection (1), hypokinetic cardiomyopathy (2), lung parenchymal abnormalities (5), and hiatus hernia (1). Inter-observer agreement ranged from 0.76 to 1 between senior radiologists and from 0.76 to 1 between resident and senior radiologists. The average time of image interpretation ranged from 14 to 15 minutes. CONCLUSION: ECG-gated whole chest CT angiography appears as a promising tool for the evaluation of acute chest pain. Combined evaluation of appearance and function of the myocardium can reveal additional interesting information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although U-clip anastomoses were studied for hemodynamics and patency, their potential for unimpeded growth after congenital cardiovascular surgery has not been investigated yet. In 53 children aged 2.1+/-3.3 years operated on between March 1998 and August 2005 growth of U-clip (U) vs. polypropylene running sutured (P) anastomoses in coarctation repair (Coarc; n=26), bi-directional Glenn (BDG; n=13) and arterial switch operation (ASO; n=14) was retrospectively analysed. Coarc showed 2.39+/-4.33 vs. 3.09+/-2.24 mm of growth during the observation period (21+/-16 vs. 30+/-27 months); no growth (0 vs.16%), restenosis (14 vs. 37%) and reinterventions (14 vs. 11%) were similar (all in U vs. P, P=ns). BDG showed 3.68+/-3.43 vs. 2.50+/-2.55 mm (P=ns) of growth during 15+/-5 vs. 29+/-18 months (P=0.046); no growth (17 vs. 0%), stenosis (0 vs. 14%) and reinterventions (0%) were similar in U vs. P, respectively (P=ns). Main pulmonary artery (MPA) anastomosis in ASO showed 0.28+/-1.73 vs. 1.30+/-3.16 mm of growth during 8+/-14 vs. 28+/-28 months; no growth (60 vs. 14%), stenosis (50 vs. 63%) and reinterventions (0%) were similar (all in U vs. P, P=ns). Anastomotic growth, stenosis and reintervention rates show no difference between interrupted U-clip and polypropylene running sutured technique in Coarc repair, BDG and MPA anastomosis in ASO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To examine the prevalence of sustained ventricular tachycardia (VT) and sudden death (SD) in adults with atrial repair of transposition of the great arteries (TGA) and to determine associated risk factors. METHODS AND RESULTS: In a single-centre review, we studied the outcome of 149 adults (mean age 28 +/- 7 years) who had undergone a Mustard operation for TGA. During a mean follow-up of 9 +/- 6 years, sustained VT and/or SD occurred in 9% (13/149) of the cohort. Sustained VT/SD was more likely to occur in patients with associated anatomic lesions [hazard ratio (HR) 4.9, 95% CI 1.5-16.0], with NYHA class >or=III (HR 9.8, 95% CI 3.0-31.6) and with an impaired subaortic right ventricular (RV) ejection fraction (EF) (HR 2.2, 95% CI 1.2-4.0 per 10% decrease in EF). There was an inverse correlation between the RV-EF and both age and QRS duration. Patients with a QRS duration >or=140 ms were at highest risk of sustained VT/SD (HR 13.6, 95% CI 2.9-63.4). Atrial tachyarrhythmia was detected in 66 (44%) patients, but was not a statistically significant predictor of sustained VT/SD in our adult population (HR 2.7, 95% CI 0.6-13.0). CONCLUSION: Sustained VT/SD in adults after a Mustard operation for TGA are more common than previously described. Age, systemic ventricular function, and QRS duration are interrelated and are associated with VT/SD. A QRS duration >or=140 ms helps to identify the high risk patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A comatose 30-month-old, entire male boxer was presented because of an acute history of a cluster of three to four seizures. Neurological examination suggested a diffuse to multifocal intracranial lesion. Magnetic resonance tomography revealed symmetrical multifocal to diffuse changes of the cerebral grey matter and ependymal lining with sediment in the lateral ventricles. Haematological examination revealed leucocytosis with neutrophilia. Cerebrospinal fluid examination revealed high protein concentration and polymorphonuclear pleocytosis. Despite antiepileptic treatment, therapy against increased intracranial pressure and antibiosis, the dog's condition continued to deteriorate and he was euthanased. Pathological examination revealed fibrinosuppurative meningo-ependymitis and necrotising arteritis throughout the brain. In addition, chronic inflammation and arterial stenosis was found in the spinal meninges. No infectious agent was found. A diagnosis of steroid-responsive meningitis arteritis was made. The massive extension into the meninges and ventricular system of the forebrain has not been described previously in dogs with steroid-responsive meningitis arteritis and should be considered in the differential diagnosis when an intracranial suppurative infection is suspected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The impact of diagnostic delay (a period from appearance of first symptoms to diagnosis) on the clinical course of Crohn's disease (CD) is unknown. We examined whether length of diagnostic delay affects disease outcomes. METHODS Data from the Swiss IBD cohort study were analyzed. Patients were recruited from university centers (68%), regional hospitals (14%), and private practices (18%). The frequencies of occurrence of bowel stenoses, internal fistulas, perianal fistulas, and CD-related surgery (intestinal and perianal) were analyzed. RESULTS A total of 905 CD patients (53.4% female, median age at diagnosis 26 (20-36) years) were stratified into four groups according to the quartiles of diagnostic delay (0-3, 4-9, 10-24, and ≥25 months, respectively). Median diagnostic delay was 9 (3-24) months. The frequency of immunomodulator and/or antitumor necrosis factor drug use did not differ among the four groups. The length of diagnostic delay was positively correlated with the occurrence of bowel stenosis (odds ratio (OR) 1.76, P=0.011 for delay of ≥25 months) and intestinal surgery (OR 1.76, P=0.014 for delay of 10-24 months and OR 2.03, P=0.003 for delay of ≥25 months). Disease duration was positively associated and non-ileal disease location was negatively associated with bowel stenosis (OR 1.07, P<0.001, and OR 0.41, P=0.005, respectively) and intestinal surgery (OR 1.14, P<0.001, and OR 0.23, P<0.001, respectively). CONCLUSIONS The length of diagnostic delay is correlated with an increased risk of bowel stenosis and CD-related intestinal surgery. Efforts should be undertaken to shorten the diagnostic delay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve. RESULTS 16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66). CONCLUSIONS Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: We aimed to assess the impact of B-type natriuretic peptide (BNP) on short-term outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results: Of 500 consecutive patients with severe aortic stenosis undergoing TAVI at our institution, we studied 340 patients who had a BNP assessment prior to TAVI. Patients were divided into tertiles - low: BNP ≤201 pg/mL (n=114), mid: BNP 202-595 pg/mL (n=113) and high: BNP ≥596 pg/mL (n=113). The primary endpoint was all-cause mortality, cardiac death and major adverse cardiac and cerebrovascular events (MACCE; death, major stroke and myocardial infarction) at 30 days. Compared with low tertile, high tertile patients were at higher baseline surgical risk (STS score 5.5±3.0 vs. 7.4±4.1, p=0.002). On echocardiography, high tertile patients had smaller valve areas (0.74±0.21 vs. 0.66±0.23 cm2, p=0.008), higher left ventricular (LV) mass indices (123.40±33.66 vs. 168.22±47.96 g/m2, p<0.001) and lower LV ejection fractions (61.59±7.18 vs. 42.65±15.41%, p<0.001) as compared with low tertile patients. At 30 days, a significantly higher incidence of death (hazard ratio [HR] 7.41, p=0.001) cardiac death (HR 5.82, p=0.006) and MACCE (HR 9.04, p<0.001) was observed among high as compared to low tertile patients. Conclusions: In TAVI patients, higher BNP values at baseline are associated with an increased risk for an adverse event periprocedurally and after 30 days, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND & AIMS Development of strictures is a major concern for patients with eosinophilic esophagitis (EoE). At diagnosis, EoE can present with an inflammatory phenotype (characterized by whitish exudates, furrows, and edema), a stricturing phenotype (characterized by rings and stenosis), or a combination of these. Little is known about progression of stricture formation; we evaluated stricture development over time in the absence of treatment and investigated risk factors for stricture formation. METHODS We performed a retrospective study using the Swiss EoE Database, collecting data on 200 patients with symptomatic EoE (153 men; mean age at diagnosis, 39 ± 15 years old). Stricture severity was graded based on the degree of difficulty associated with passing of the standard adult endoscope. RESULTS The median delay in diagnosis of EoE was 6 years (interquartile range, 2-12 years). With increasing duration of delay in diagnosis, the prevalence of fibrotic features of EoE, based on endoscopy, increased from 46.5% (diagnostic delay, 0-2 years) to 87.5% (diagnostic delay, >20 years; P = .020). Similarly, the prevalence of esophageal strictures increased with duration of diagnostic delay, from 17.2% (diagnostic delay, 0-2 years) to 70.8% (diagnostic delay, >20 years; P < .001). Diagnostic delay was the only risk factor for strictures at the time of EoE diagnosis (odds ratio = 1.08; 95% confidence interval: 1.040-1.122; P < .001). CONCLUSIONS The prevalence of esophageal strictures correlates with the duration of untreated disease. These findings indicate the need to minimize delay in diagnosis of EoE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy. BACKGROUND Since its commercialization in 2007, the number of TAVR procedures has grown exponentially. METHODS The adoption of TAVR was investigated in 11 European countries: Germany, France, Italy, United Kingdom, Spain, the Netherlands, Switzerland, Belgium, Portugal, Denmark, and Ireland. Data were collected from 2 sources: 1) lead physicians submitted nation-specific registry data; and 2) an implantation-based TAVR market tracker. Economic indexes such as healthcare expenditure per capita, sources of healthcare funding, and reimbursement strategies were correlated to TAVR use. Furthermore, we assessed the extent to which TAVR has penetrated its potential patient population. RESULTS Between 2007 and 2011, 34,317 patients underwent TAVR. Considerable variation in TAVR use existed across nations. In 2011, the number of TAVR implants per million individuals ranged from 6.1 in Portugal to 88.7 in Germany (33 ± 25). The annual number of TAVR implants performed per center across nations also varied widely (range 10 to 89). The weighted average TAVR penetration rate was low: 17.9%. Significant correlation was found between TAVR use and healthcare spending per capita (r = 0.80; p = 0.005). TAVR-specific reimbursement systems were associated with higher TAVR use than restricted systems (698 ± 232 vs. 213 ± 112 implants/million individuals ≥ 75 years; p = 0.002). CONCLUSIONS The authors' findings indicate that TAVR is underutilized in high and prohibitive surgical risk patients with severe aortic stenosis. National economic indexes and reimbursement strategies are closely linked with TAVR use and help explain the inequitable adoption of this therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) constitutes a relatively new treatment option for the patients with severe symptomatic aortic stenosis. Evidence from registries and randomized control trials has underscored the value of this treatment in inoperable and high risk populations, while new developments in valve technology and TAVR enabling devices have reduced the risk of complications, simplified the procedure, and broadened the applications of this therapy. The initial promising clinical results and the potential of an effective less invasive treatment of aortic stenosis has not only created high expectations but also the need to address the pitfalls of TAVR technology. The evolving knowledge concerning the groups of patients who would benefit from this treatment, the limited long term follow-up data, the concerns about devices' long term durability, and the severity of complications remain important caveats which restrict the widespread clinical adoption of TAVR. The aim of this review article is to present the recent advances, highlight the limitations of TAVR technology, and discuss the future perspectives in this rapidly evolving field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI) clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection. BACKGROUND A recent study confirmed that VARC definitions have already been incorporated into clinical and research practice and represent a new standard for consistency in reporting clinical outcomes of patients with symptomatic severe aortic stenosis (AS) undergoing TAVI. However, as the clinical experience with this technology has matured and expanded, certain definitions have become unsuitable or ambiguous. METHODS AND RESULTS Two in-person meetings (held in September 2011 in Washington, DC, and in February 2012 in Rotterdam, The Netherlands) involving VARC study group members, independent experts (including surgeons, interventional and noninterventional cardiologists, imaging specialists, neurologists, geriatric specialists, and clinical trialists), the US Food and Drug Administration (FDA), and industry representatives, provided much of the substantive discussion from which this VARC-2 consensus manuscript was derived. This document provides an overview of risk assessment and patient stratification that need to be considered for accurate patient inclusion in studies. Working groups were assigned to define the following clinical endpoints: mortality, stroke, myocardial infarction, bleeding complications, acute kidney injury, vascular complications, conduction disturbances and arrhythmias, and a miscellaneous category including relevant complications not previously categorized. Furthermore, comprehensive echocardiographic recommendations are provided for the evaluation of prosthetic valve (dys)function. Definitions for the quality of life assessments are also reported. These endpoints formed the basis for several recommended composite endpoints. CONCLUSIONS This VARC-2 document has provided further standardization of endpoint definitions for studies evaluating the use of TAVI, which will lead to improved comparability and interpretability of the study results, supplying an increasingly growing body of evidence with respect to TAVI and/or surgical aortic valve replacement. This initiative and document can furthermore be used as a model during current endeavors of applying definitions to other transcatheter valve therapies (for example, mitral valve repair).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a widely accepted alternative to surgical aortic valve replacement (SAVR) among non-operable patients or selected high-risk patients with degenerative, severe aortic stenosis. TAVI is considered less invasive when compared with SAVR; however, there remain significant differences between different TAVI access routes. The transfemoral approach is considered the least invasive access route, and can be performed as a fully percutaneous procedure in a spontaneously breathing patient under local anaesthesia and mild sedation only. Moreover, transfemoral TAVI patients are typically transferred to coronary care rather than to an intensive care unit after the procedure, and benefit from early ambulation and a reduction in overall length of hospital stay. Considering these patient-specific and health-economic advantages, several TAVI centres follow the least invasive strategy for their patients and have implemented the transfemoral access route as the default access in their institutions. This article provides an overview on the prerequisites for a successful transfemoral TAVI procedure, describes the procedural advantages compared to alternative access routes, and highlights differences in clinical outcomes.