174 resultados para MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY
Resumo:
PURPOSE Pancreatic ductal adenocarcinoma (PDAC) surveillance programs are currently offered to high-risk individuals aiming to detect precursor lesions or PDAC at an early stage. We assessed differences in frequency and behavior of precursor lesions and PDAC between two high-risk groups. EXPERIMENTAL DESIGN Individuals with a p16-Leiden germline mutation (N = 116; median age 54 years) and individuals from familial pancreatic cancer (FPC) families (N = 125; median age 47 years) were offered annual surveillance by MRI and magnetic resonance cholangiopancreatography (MRCP) with or without endoscopic ultrasound (EUS) for a median surveillance period of 34 months (0-127 months) or 36 months (0-110 months), respectively. Detailed information was collected on pancreatic cystic lesions detected on MRCP and precursor lesions in surgical specimens of patients who underwent pancreatic surgery. RESULTS Cystic lesions were more common in the FPC cohort (42% vs. 16% in p16-Leiden cohort), whereas PDAC was more common in the p16-Leiden cohort (7% vs. 0.8% in FPC cohort). Intraductal papillary mucinous neoplasm (IPMN) was a common finding in surgical specimens of FPC-individuals, and was only found in two patients of the p16-Leiden cohort. In the p16-Leiden cohort, a substantial proportion of cystic lesions showed growth or malignant transformation during follow-up, whereas in FPC individuals most cystic lesions remain stable. CONCLUSION In p16-Leiden mutation carriers, cystic lesions have a higher malignant potential than in FPC-individuals. On the basis of these findings, a more intensive surveillance program may be considered in this high-risk group.
Resumo:
Soon after its introduction in 1991, MR cholangiopancreatography has become an established diagnostic tool for the evaluation of the pancreaticobiliary ductal system at a field strength of 1.5T. It remains unclear whether MR cholangiopancreatography performed at 3T will benefit from the higher magnetic field strength or whether a field strength of 1.5T should continue to be considered the gold standard for MR cholangiopancreatography. This article reviews the current literature on the benefits and drawbacks of MR cholangiopancreatography at 3T compared with a standard field strength of 1.5T. Field strength-related artifacts that affect MR cholangiopancreatography at 3T also are discussed.
Resumo:
Magnetic iron oxide nanoparticles have found application as contrast agents for magnetic resonance imaging (MRI) and as switchable drug delivery vehicles. Their stabilization as colloidal carriers remains a challenge. The potential of poly(ethylene imine)-g-poly(ethylene glycol) (PEGPEI) as stabilizer for iron oxide (γ-Fe₂O₃) nanoparticles was studied in comparison to branched poly(ethylene imine) (PEI). Carrier systems consisting of γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were prepared and characterized regarding their physicochemical properties including magnetic resonance relaxometry. Colloidal stability of the formulations was tested in several media and cytotoxic effects in adenocarcinomic epithelial cells were investigated. Synthesized γ-Fe₂O₃ cores showed superparamagnetism and high degree of crystallinity. Diameters of polymer-coated nanoparticles γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were found to be 38.7 ± 1.0 nm and 40.4 ± 1.6 nm, respectively. No aggregation tendency was observable for γ-Fe₂O₃-PEGPEI over 12 h even in high ionic strength media. Furthermore, IC₅₀ values were significantly increased by more than 10-fold when compared to γ-Fe₂O₃-PEI. Formulations exhibited r₂ relaxivities of high numerical value, namely around 160 mM⁻¹ s⁻¹. In summary, novel carrier systems composed of γ-Fe₂O₃-PEGPEI meet key quality requirements rendering them promising for biomedical applications, e.g. as MRI contrast agents.
Resumo:
Auditory hallucinations comprise a critical domain of psychopathology in schizophrenia. Repetitive transcranial magnetic stimulation (TMS) has shown promise as an intervention with both positive and negative reports. The aim of this study was to test resting-brain perfusion before treatment as a possible biological marker of response to repetitive TMS. Twenty-four medicated patients underwent resting-brain perfusion magnetic resonance imaging with arterial spin labeling (ASL) before 10 days of repetitive TMS treatment. Response was defined as a reduction in the hallucination change scale of at least 50%. Responders (n=9) were robustly differentiated from nonresponders (n=15) to repetitive TMS by the higher regional cerebral blood flow (CBF) in the left superior temporal gyrus (STG) (P<0.05, corrected) before treatment. Resting-brain perfusion in the left STG predicted the response to repetitive TMS in this study sample, suggesting this parameter as a possible bio-marker of response in patients with schizophrenia and auditory hallucinations. Being noninvasive and relatively easy to use, resting perfusion measurement before treatment might be a clinically relevant way to identify possible responders and nonresponders to repetitive TMS.
Resumo:
Transcranial magnetic stimulation (TMS) is a novel therapeutic approach, used in patients with pharmacoresistant auditory verbal hallucinations (AVH). To investigate the neurobiological effects of TMS on AVH, we measured cerebral blood flow with pseudo-continuous magnetic resonance-arterial spin labeling 20 ± 6 hours before and after TMS treatment.
Resumo:
The aim of the current study was to examine the effect of theta burst repetitive transcranial magnetic stimulation (rTMS) on the blood oxygenation level-dependent (BOLD) activation during repeated functional magnetic resonance imaging (fMRI) measurements. Theta burst rTMS was applied over the right frontal eye field in seven healthy subjects. Subsequently, repeated fMRI measurements were performed during a saccade-fixation task (block design) 5, 20, 35, and 60 min after stimulation. We found that theta burst rTMS induced a strong and long-lasting decrease of the BOLD signal response of the stimulated frontal eye field at 20 and 35 min. Furthermore, less pronounced alterations of the BOLD signal response with different dynamics were found for remote oculomotor areas such as the left frontal eye field, the pre-supplementary eye field, the supplementary eye field, and both parietal eye fields. Recovery of the BOLD signal changes in the anterior remote areas started earlier than in the posterior remote areas. These results show that a) the major inhibitory impact of theta burst rTMS occurs directly in the stimulated area itself, and that b) a lower effect on remote, oculomotor areas can be induced.
Resumo:
PURPOSE Precise temperature measurements in the magnetic field are indispensable for MR safety studies and for temperature calibration during MR-guided thermotherapy. In this work, the interference of two commonly used fiber-optical temperature measurement systems with the static magnetic field B0 was determined. METHODS Two fiber-optical temperature measurement systems, a GaAs-semiconductor and a phosphorescent phosphor ceramic, were compared for temperature measurements in B0 . The probes and a glass thermometer for reference were placed in an MR-compatible tube phantom within a water bath. Temperature measurements were carried out at three different MR systems covering static magnetic fields up to B0 = 9.4T, and water temperatures were changed between 25°C and 65°C. RESULTS The GaAs-probe significantly underestimated absolute temperatures by an amount related to the square of B0 . A maximum difference of ΔT = -4.6°C was seen at 9.4T. No systematic temperature difference was found with the phosphor ceramic probe. For both systems, the measurements were not dependent on the orientation of the sensor to B0 . CONCLUSION Temperature measurements with the phosphor ceramic probe are immune to magnetic fields up to 9.4T, whereas the GaAs-probes either require a recalibration inside the MR system or a correction based on the square of B0 . Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.