297 resultados para CT angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: The aim of our study was to demonstrate the image quality of the new device using human cadavers, extending the horizon of available imaging modalities in forensic medicine. MATERIALS AND METHODS: Six human cadavers were examined, revealing C-arm data sets of the head, neck thorax, abdomen and pelvis. High-resolution mode was performed with 500 fluoroscopy shots during a 190 degrees orbital movement with a constant tube voltage of 100 kV and a current of 4.6 mA. Based on these data sets subsequent three-dimensional reconstructions were generated. RESULTS: Reconstructed data sets revealed high-resolution images of all skeletal structures in a near-CT quality. The same image quality was available in all reconstruction planes. Artefacts caused by restorative dental materials are less accentuated in CBCT data sets. The system configuration was not powerful enough to generate sufficient images of intracranial structures. CONCLUSION: After the here-demonstrated encouraging preliminary results, the forensic indications that would be suitable for imaging with a 3D C-arm have to be defined. Promising seems the visualization local limited region of interest as the cervical spine or the facial skeleton.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conversion of computed tomography (CT) numbers into material composition and mass density data influences the accuracy of patient dose calculations in Monte Carlo treatment planning (MCTP). The aim of our work was to develop a CT conversion scheme by performing a stoichiometric CT calibration. Fourteen dosimetrically equivalent tissue subsets (bins), of which ten bone bins, were created. After validating the proposed CT conversion scheme on phantoms, it was compared to a conventional five bin scheme with only one bone bin. This resulted in dose distributions D(14) and D(5) for nine clinical patient cases in a European multi-centre study. The observed local relative differences in dose to medium were mostly smaller than 5%. The dose-volume histograms of both targets and organs at risk were comparable, although within bony structures D(14) was found to be slightly but systematically higher than D(5). Converting dose to medium to dose to water (D(14) to D(14wat) and D(5) to D(5wat)) resulted in larger local differences as D(5wat) became up to 10% higher than D(14wat). In conclusion, multiple bone bins need to be introduced when Monte Carlo (MC) calculations of patient dose distributions are converted to dose to water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the radiation dose delivered to organs during standard computed tomographic (CT) examination of the trunk. MATERIALS AND METHODS: In vivo locations and sizes of specific body organs were determined from CT images of patients who underwent examinations. The corresponding CT investigations were then simulated on an anthropomorphic phantom. The resulting doses were measured at 70 different sites inside the phantom by using thermoluminescent dosimeters. On the basis of measurements of free-in-air air kerma at the rotation axis of the CT gantry, conversion factors were calculated so that measurements could be used with different models of CT equipment. RESULTS: Starting from the dose values recorded, the mean organ doses were determined for 21 organs. The skin received 22-36 mGy; the lungs, less than 1-18 mGy; the kidneys, 7-24 mGy; and the ovaries, less than 1-19 mGy, depending on the type of CT examination performed. CONCLUSION: These values are high compared with other x-ray examinations and should be minimized as much as possible. The number of tomographic sections obtained should be kept as low as possible according to diagnostic need.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Similarity measure is one of the main factors that affect the accuracy of intensity-based 2D/3D registration of X-ray fluoroscopy to CT images. Information theory has been used to derive similarity measure for image registration leading to the introduction of mutual information, an accurate similarity measure for multi-modal and mono-modal image registration tasks. However, it is known that the standard mutual information measure only takes intensity values into account without considering spatial information and its robustness is questionable. Previous attempt to incorporate spatial information into mutual information either requires computing the entropy of higher dimensional probability distributions, or is not robust to outliers. In this paper, we show how to incorporate spatial information into mutual information without suffering from these problems. Using a variational approximation derived from the Kullback-Leibler bound, spatial information can be effectively incorporated into mutual information via energy minimization. The resulting similarity measure has a least-squares form and can be effectively minimized by a multi-resolution Levenberg-Marquardt optimizer. Experimental results are presented on datasets of two applications: (a) intra-operative patient pose estimation from a few (e.g. 2) calibrated fluoroscopic images, and (b) post-operative cup alignment estimation from single X-ray radiograph with gonadal shielding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimal temporal window of intravenous (IV) computed tomography (CT) cholangiography was prospectively determined. Fifteen volunteers (eight women, seven men; mean age, 38 years) underwent dynamic CT cholangiography. Two unenhanced images were acquired at the porta hepatis. Starting 5 min after initiation of IV contrast infusion (20 ml iodipamide meglumine 52%), 15 pairs of images at 5-min intervals were obtained. Attenuation of the extrahepatic bile duct (EBD) and the liver parenchyma was measured. Two readers graded visualization of the higher-order biliary branches. The first biliary opacification in the EBD occurred between 15 and 25 min (mean, 22.3 min +/- 3.2) after initiation of the contrast agent. Biliary attenuation plateaued between the 35- and the 75-min time points. Maximum hepatic parenchymal enhancement was 18.5 HU +/- 2.7. Twelve subjects demonstrated poor or non-visualization of higher-order biliary branches; three showed good or excellent visualization. Body weight and both biliary attenuation and visualization of the higher-order biliary branches correlated significantly (P<0.05). For peak enhancement of the biliary tree, CT cholangiography should be performed no earlier than 35 min after initiation of IV infusion. For a fixed contrast dose, superior visualization of the biliary system is achieved in subjects with lower body weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine quantitatively and qualitatively the timing of maximal enhancement of the normal small-bowel wall by using contrast material-enhanced multi-detector row computed tomography (CT). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. After information on radiation risk was given, written informed consent was obtained from 25 participants with no history of small-bowel disease (mean age, 58 years; 19 men) who had undergone single-level dynamic CT. Thirty seconds after the intravenous administration of contrast material, a serial dynamic acquisition, consisting of 10 images obtained 5 seconds apart, was performed. Enhancement measurements were obtained over time from the small-bowel wall and the aorta. Three independent readers qualitatively assessed small-bowel conspicuity. Quantitative and qualitative data were analyzed during the arterial phase, the enteric phase (which represented peak small-bowel mural enhancement), and the venous phase. Statistical analysis included paired Student t test and Wilcoxon signed rank test with Bonferroni correction. A P value less than .05 was used to indicate a significant difference. RESULTS: The mean time to peak enhancement of the small-bowel wall was 49.3 seconds +/- 7.7 (standard deviation) and 13.5 seconds +/- 7.6 after peak aortic enhancement. Enhancement values were highest during the enteric phase (P < .05). Regarding small-bowel conspicuity, images obtained during the enteric phase were most preferred qualitatively; there was a significant difference between the enteric and arterial phases (P < .001) but not between the enteric and venous phases (P = .18). CONCLUSION: At multi-detector row CT, peak mural enhancement of the normal small bowel occurs on average about 50 seconds after intravenous administration of contrast material or 14 seconds after peak aortic enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: For selected stroke patients, intra-arterial thrombolysis (IAT) has been shown to be an effective treatment option. However, knowledge of safety and efficacy of IAT in patients with acute stroke as a complication of arterial catheter interventions is limited. METHODS: We analyzed clinical radiological findings and functional outcomes in consecutive patients 3 months after treatment with IAT for peri-procedural strokes occurring during neuroendovascular or cardiac catheter interventions. To measure outcome, the modified Rankin scale score was used. RESULTS: Of a total of 432 patients treated with IAT, 12 (4 women and 8 men; mean age, 60 years) were treated because of an ischemic stroke after a neuro-endovascular procedure (n=6) or coronary angiography (n=6). The median baseline National Institutes of Health Stroke Scale score was 15. Recanalization was complete (thrombolysis in myocardial infarction grade 3) in 6, partial (thrombolysis in myocardial infarction 2) in 5, and minimal (thrombolysis in myocardial infarction 1) in 1. Nine patients (75%) had a favorable outcome (modified Rankin scale score, 0 to 2), and 3 had a poor outcome (modified Rankin scale score, 3 or 4). All patients with complete recanalization had a favorable outcome, whereas only 3 of 6 patients with partial or minimal recanalization (P=0.18) had a favorable outcome. Follow-up brain imaging was normal in 2 and showed new ischemic lesions in 10 patients. Two patients (17%) had a symptomatic intracerebral hemorrhage. CONCLUSIONS: In acute stroke attributable to arterial catheter interventions, IAT is feasible and has the potential to improve outcome in these patients. A high recanalization rate could be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of our study was to evaluate the efficacy of CT histogram analysis for further characterization of lipid-poor adenomas on unenhanced CT. MATERIALS AND METHODS: One hundred thirty-two adrenal nodules were identified in 104 patients with lung cancer who underwent PET/CT. Sixty-five nodules were classified as lipid-rich adenomas if they had an unenhanced CT attenuation of less than or equal to 10 H. Thirty-one masses were classified as lipid-poor adenomas if they had an unenhanced CT attenuation greater than 10 H and stability for more than 1 year. Thirty-six masses were classified as lung cancer metastases if they showed rapid growth in 1 year (n = 27) or were biopsy-proven (n = 9). Histogram analysis was performed for all lesions to provide the mean attenuation value and percentage of negative pixels. RESULTS: All lipid-rich adenomas had more than 10% negative pixels; 51.6% of lipid-poor adenomas had more than 10% negative pixels and would have been classified as indeterminate nodules on the basis of mean attenuation alone. None of the metastases had more than 10% negative pixels. Using an unenhanced CT mean attenuation threshold of less than 10 H yielded a sensitivity of 68% and specificity of 100% for the diagnosis of an adenoma. Using an unenhanced CT threshold of more than 10% negative pixels yielded a sensitivity of 84% and specificity of 100% for the diagnosis of an adenoma. CONCLUSION: CT histogram analysis is superior to mean CT attenuation analysis for the evaluation of adrenal nodules and may help decrease referrals for additional imaging or biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate, for the depiction of simulated hypervascular liver lesions in a phantom, the effect of a low tube voltage, high tube current computed tomographic (CT) technique on image noise, contrast-to-noise ratio (CNR), lesion conspicuity, and radiation dose. MATERIALS AND METHODS: A custom liver phantom containing 16 cylindric cavities (four cavities each of 3, 5, 8, and 15 mm in diameter) filled with various iodinated solutions to simulate hypervascular liver lesions was scanned with a 64-section multi-detector row CT scanner at 140, 120, 100, and 80 kVp, with corresponding tube current-time product settings at 225, 275, 420, and 675 mAs, respectively. The CNRs for six simulated lesions filled with different iodinated solutions were calculated. A figure of merit (FOM) for each lesion was computed as the ratio of CNR2 to effective dose (ED). Three radiologists independently graded the conspicuity of 16 simulated lesions. An anthropomorphic phantom was scanned to evaluate the ED. Statistical analysis included one-way analysis of variance. RESULTS: Image noise increased by 45% with the 80-kVp protocol compared with the 140-kVp protocol (P < .001). However, the lowest ED and the highest CNR were achieved with the 80-kVp protocol. The FOM results indicated that at a constant ED, a reduction of tube voltage from 140 to 120, 100, and 80 kVp increased the CNR by factors of at least 1.6, 2.4, and 3.6, respectively (P < .001). At a constant CNR, corresponding reductions in ED were by a factor of 2.5, 5.5, and 12.7, respectively (P < .001). The highest lesion conspicuity was achieved with the 80-kVp protocol. CONCLUSION: The CNR of simulated hypervascular liver lesions can be substantially increased and the radiation dose reduced by using an 80-kVp, high tube current CT technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To perform a quantitative and qualitative comparison of gadobutrol and gadoterate in three-station contrast enhanced magnetic resonance angiography (CE-MRA) of the lower limbs. MATERIALS AND METHODS: In this prospective randomized controlled trial, 52 patients with leg ischemia were randomly assigned to one of two groups receiving either gadobutrol (1.0 mmol Gd/mL, 15 mL) or gadoterate (0.5 mmol Gd/mL, 30 mL). Three-station 3D CE-MRAs from the pelvis to the ankles were performed with moving-table technique on a 1.5T MR scanner. Injection time was identical in both groups. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for 816 arteries. Contrast quality in 1196 vessel segments was evaluated separately by two blinded readers on a three-point scale. RESULTS: Mean SNR (61.8 +/- 7.8 for gadobutrol vs. 61.9 +/- 9.1 for gadoterate, P = 0.257), CNR (52.8 +/- 9.1 vs. 52.8 +/- 10.7, P = 0.154), and qualitative ranking (1.41 vs. 1.44, P = 0.21) for all vessels did not differ significantly between the two patient groups. The overall quality was good in 90.4% with gadoterate and 94.2% with gadobutrol (P = 0.462). CONCLUSION: High-concentration gadobutrol allows neither a higher CNR nor any qualitative advantage over the ordinary unspecific Gd agent gadoterate when the same Gd load and injection times are used in multistation CE-MRA of the peripheral arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem examination of chest trauma is an important domain in forensic medicine, which is today performed using autopsy. Since the implementation of cross-sectional imaging methods in forensic medicine such as computed tomography (CT) and magnetic resonance imaging (MRI), a number of advantages in comparison with autopsy have been described. Within the scope of validation of cross-sectional radiology in forensic medicine, the comparison of findings of postmortem imaging and autopsy in chest trauma was performed. METHODS: This retrospective study includes 24 cases with chest trauma that underwent postmortem CT, MRI, and autopsy. Two board-certified radiologists, blind to the autopsy findings, evaluated the radiologic data independently. Each radiologist interpreted postmortem CT and MRI data together for every case. The comparison of the results of the radiologic assessment with the autopsy and a calculation of interobserver discrepancy was performed. RESULTS: Using combined CT and MRI, between 75% and 100% of the investigated findings, except for hemomediastinum (70%), diaphragmatic ruptures (50%; n=2) and heart injury (38%), were discovered. Although the sensitivity and specificity regarding pneumomediastinum, pneumopericardium, and pericardial effusion were not calculated, as these findings were not mentioned at the autopsy, these findings were clearly seen radiologically. The averaged interobserver concordance was 90%. CONCLUSION: The sensitivity and specificity of our results demonstrate that postmortem CT and MRI are useful diagnostic methods for assessing chest trauma in forensic medicine as a supplement to autopsy. Further radiologic-pathologic case studies are necessary to define the role of postmortem CT and MRI as a single examination modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to adapt and improve a minimally invasive two-step postmortem angiographic technique for use on human cadavers. Detailed mapping of the entire vascular system is almost impossible with conventional autopsy tools. The technique described should be valuable in the diagnosis of vascular abnormalities. MATERIALS AND METHODS: Postmortem perfusion with an oily liquid is established with a circulation machine. An oily contrast agent is introduced as a bolus injection, and radiographic imaging is performed. In this pilot study, the upper or lower extremities of four human cadavers were perfused. In two cases, the vascular system of a lower extremity was visualized with anterograde perfusion of the arteries. In the other two cases, in which the suspected cause of death was drug intoxication, the veins of an upper extremity were visualized with retrograde perfusion of the venous system. RESULTS: In each case, the vascular system was visualized up to the level of the small supplying and draining vessels. In three of the four cases, vascular abnormalities were found. In one instance, a venous injection mark engendered by the self-administration of drugs was rendered visible by exudation of the contrast agent. In the other two cases, occlusion of the arteries and veins was apparent. CONCLUSION: The method described is readily applicable to human cadavers. After establishment of postmortem perfusion with paraffin oil and injection of the oily contrast agent, the vascular system can be investigated in detail and vascular abnormalities rendered visible.