249 resultados para ARTERY-DISEASE
Resumo:
BACKGROUND: Chronic thromboembolic pulmonary hypertension is a late sequela following acute pulmonary embolism. Incomplete resolution of thrombotic material results in persistent obstruction of the pulmonary arterial bed, which can be treated by pulmonary thrombendarterectomy. METHOD AND RESULTS: This desobliteration of the pulmonary arteries is performed under conditions of deep hypothermia and circulatory arrest. Currently, perioperative mortality ranges between 10 and 15% and is mainly limited by persistent diffuse pulmonary artery disease independent of central obstruction. Postoperatively, pulmonary vascular resistance is normalized. Exercise tolerance of the patients is likewise improved. CONCLUSION: Thus, pulmonary thrombendarterectomy is an effective treatment for chronic thromboembolic pulmonary hypertension with results superior to those of lung transplantation.
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Recent studies have suggested placental growth factor (PlGF) and vascular endothelial growth factor (VEGF) as promising new biomarkers for risk stratification in acute coronary syndromes (ACS). However, little is known about the influence of percutaneous coronary intervention (PCI) on circulating PlGF and VEGF levels. METHODS: Thirty-five patients with ACS, 27 patients with stable coronary artery disease (sCAD), and nine healthy controls were enrolled in the study. Although all patients with ACS and 14 patients with stable angina pectoris underwent PCI, 13 patients with coronary artery disease required no revascularization (sCAD). PlGF and VEGF plasma concentrations were measured by immunoassay during and at the end of PCI and coronary angiography. RESULTS: Plasma PlGF levels were comparable in patients with ACS and sCAD on admission. Although coronary angiography or heparin alone did not alter PlGF and VEGF levels, immediately after PCI a dramatic increase was seen in circulating PlGF and a decrease in VEGF, which was independent of the clinical presentation of the patients, heparin administration, or the angiographic procedure itself, but was associated with the extent of coronary artery disease and the amount of the injected contrast media. In-vitro experiments revealed that radiocontrast agents induced the release of PlGF from endothelial cells without altering PlGF mRNA expression. CONCLUSION: Patients undergoing PCI exhibit an increase in circulating PlGF, probably caused by posttranslational modifications of radiocontrast agents in endothelial cells. Therefore, analysis of plasma PlGF and VEGF levels may consider the timing of blood sampling with respect to PCI and contrast media exposure.
Resumo:
Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.
Resumo:
Coronary artery disease is prevalent in patients who have severe emphysema and who are being considered for lung volume reduction surgery (LVRS). Significant valvular heart diseases may also coexist in these patients. Few thoracic surgeons have performed LVRS in patients who have severe cardiac diseases. Conversely, few cardiac surgeons have been willing to undertake major cardiac surgery in patients who have severe emphysema. This report reviews the evidence regarding combined cardiac surgery and LVRS to determine the optimal management strategy for patients who have severe emphysema and who are suitable for LVRS, but who also have coexisting significant cardiac diseases that are operable.
Resumo:
OBJECTIVE: Vital exhaustion and depression are psychosocial risk factors of coronary artery disease. A hypercoagulable state in response to acute psychosocial stress contributes to atherothrombotic events. We aimed to investigate the hypothesis that vital exhaustion and depression correlate with stress-induced changes in the hypercoagulability marker D-dimer. METHODS: Thirty-eight healthy and nonsmoking school teachers (mean age 50+/-8 years, 55% women) completed the nine-item Maastricht Vital Exhaustion Questionnaire and the seven-item depression subscale of the Hospital Anxiety and Depression Scale. Within 1 week, subjects twice underwent the Trier Social Stress Test (i.e., preparation phase, mock job interview, and mental arithmetic that totaled 13 min). Plasma D-dimer levels were determined at five time points during the protocol. RESULTS: Vital exhaustion (P=.022; eta(2)=.080) and depressive symptoms (P=.011; eta(2)=.090) were associated with stress-induced changes in D-dimer levels over time controlling for sex and age. Elevated levels of vital exhaustion (r=-.46, P=.005) and of depression (r=-.51, P=.002) correlated with reduced D-dimer increase from pre-stress to immediately post-stress. Also, elevated vital exhaustion (r=.34, P=.044) and depression (r=.41, P=.013) were associated with increase (i.e., attenuated recovery) of D-dimer levels between 20 and 45 min post-stress. Controlling for stress hormone and blood pressure reactivity did not substantially alter these results. CONCLUSION: The findings suggest an attenuated immediate D-dimer stress response and delayed recovery of D-dimer levels post-stress with elevated vital exhaustion and depressive symptoms. In particular, the prolonged hypercoagulability after stress cessation might contribute to the atherothrombotic risk previously observed with vital exhaustion and depression, even at subclinical levels.
Resumo:
BACKGROUND: Elevated plasma fibrinogen levels have prospectively been associated with an increased risk of coronary artery disease in different populations. Plasma fibrinogen is a measure of systemic inflammation crucially involved in atherosclerosis. The vagus nerve curtails inflammation via a cholinergic antiinflammatory pathway. We hypothesized that lower vagal control of the heart relates to higher plasma fibrinogen levels. METHODS: Study participants were 559 employees (age 17-63 years; 89% men) of an airplane manufacturing plant in southern Germany. All subjects underwent medical examination, blood sampling, and 24-hour ambulatory heart rate recording while kept on their work routine. The root mean square of successive differences in RR intervals during the night period (nighttime RMSSD) was computed as the heart rate variability index of vagal function. RESULTS: After controlling for demographic, lifestyle, and medical factors, nighttime RMSSD explained 1.7% (P = 0.001), 0.8% (P = 0.033), and 7.8% (P = 0.007), respectively, of the variance in fibrinogen levels in all subjects, men, and women. Nighttime RMSSD and fibrinogen levels were stronger correlated in women than in men. In all workers, men, and women, respectively, there was a mean +/- SEM increase of 0.41 +/- 0.13 mg/dL, 0.28 +/- 0.13 mg/dL, and 1.16 +/- 0.41 mg/dL fibrinogen for each millisecond decrease in nighttime RMSSD. CONCLUSIONS: Reduced vagal outflow to the heart correlated with elevated plasma fibrinogen levels independent of the established cardiovascular risk factors. This relationship seemed comparably stronger in women than men. Such an autonomic mechanism might contribute to the atherosclerotic process and its thrombotic complications.
Resumo:
Depression and anxiety previously predicted coronary artery disease (CAD) risk. Inflammation contributes to CAD and shows an association with depression. We followed 57 teachers (mean 49+/-8 years) over 21 months and investigated whether changes in depressive and anxiety symptoms relate to those in the CAD risk and inflammation marker fibrinogen and vice versa. Increase in depressive symptoms and in fibrinogen levels were significantly correlated. While controlling for baseline depression rendered the association between changes in depression and fibrinogen nonsignificant, taking into account baseline fibrinogen levels maintained the predictive value of fibrinogen change for depression change. Anxiety and fibrinogen changes were not significantly correlated. This dynamic relationship between depression and the inflammatory biomarker fibrinogen might advance our knowledge about psychobiological mechanisms underlying both CAD and sickness behavior.
Resumo:
BACKGROUND There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis. RESULTS Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio=0.95, 95% CI=0.74-1.21, P=0.67). Target lesion revascularization was also comparable between the groups (hazard ratio=0.89, 95% CI=0.65-1.22, P=0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio=0.52, 95% CI=0.28-0.96, P=0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4years (hazard ratio=0.15, 95% CI=0.03-0.70, P=0.02). CONCLUSIONS In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4years. Rates of stent thrombosis were significantly lower with BP-DES.
Resumo:
OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.
Resumo:
AIMS The aim of our study in patients with coronary artery disease (CAD) and present, or absent, myocardial ischaemia during coronary occlusion was to test whether (i) left ventricular (LV) filling pressure is influenced by the collateral circulation and, on the other hand, that (ii) its resistance to flow is directly associated with LV filling pressure. METHODS AND RESULTS In 50 patients with CAD, the following parameters were obtained before and during a 60 s balloon occlusion: LV, aortic (Pao) and coronary pressure (Poccl), flow velocity (Voccl), central venous pressure (CVP), and coronary flow velocity after coronary angioplasty (V(Ø-occl)). The following variables were determined and analysed at 10 s intervals during occlusion, and at 60 s of occlusion: LV end-diastolic pressure (LVEDP), velocity-derived (CFIv) and pressure-derived collateral flow index (CFIp), coronary collateral (Rcoll), and peripheral resistance index to flow (Rperiph). Patients with ECG signs of ischaemia during coronary occlusion (insufficient collaterals, n = 33) had higher values of LVEDP over the entire course of occlusion than those without ECG signs of ischaemia during occlusion (sufficient collaterals, n = 17). Despite no ischaemia in the latter, there was an increase in LVEDP from 20 to 60 s of occlusion. In patients with insufficient collaterals, CFIv decreased and CFIp increased during occlusion. Beyond an occlusive LVEDP > 27 mmHg, Rcoll and Rperiph increased as a function of LVEDP. CONCLUSION Recruitable collaterals are reciprocally tied to LV filling pressure during occlusion. If poorly developed, they affect it via myocardial ischaemia; if well grown, LV filling pressure still increases gradually during occlusion despite the absence of ischaemia indicating transmission of collateral perfusion pressure to the LV. With low, but not high, collateral flow, resistance to collateral as well as coronary peripheral flow is related to LV filling pressure in the high range.
Resumo:
BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.
Resumo:
The functional relevance of coronary collaterals in humans has yet to be fully explored. Several studies demonstrated a protective role of collaterals in patients with coronary artery disease. On the other hand, negative aspects of well-developed coronary collaterals have been reported, e.g. a higher rate of restenosis following coronary angioplasty, or a redistribution of blood via collaterals away from the myocardial area in need towards normally perfused areas (coronary steal). In the past, the coronary collateral circulation has been assessed only qualitatively, using visual angiographic or nuclear imaging methods. With the recent advent of intracoronary Doppler and pressure-transducers, quantitative assessment of functional parameters of the coronary circulation has become feasible. This article reviews ongoing research in the field of coronary collaterals in humans, concerning their exact determination, the positive and negative aspects of their structure as well as their functional aspects.
Resumo:
BACKGROUND Cardiac surgery with cardiopulmonary bypass is associated with mechanical manipulation of the ascending aorta that occasionally leads to type A aortic dissection (AAD). METHODS AND RESULTS One hundred three patients with surgical repair for AAD following nonaortic cardiac surgery were identified. With the use of logistic regression modeling, coronary artery bypass surgery (CABG), either isolated or combined with another procedure in the initial operation, was associated with significantly higher operative mortality in comparison with patients with non-CABG procedures at the time of AAD repair both for all patients (odds ratio, 2.90; 95% confidence interval, 1.09-7.72; P=0.033) and for patients with acute and chronic AAD≥30 days after the initial operation (odds ratio, 3.62; 95% confidence interval, 1.13-11.54; P=0.03). In patients who developed AAD late after the initial operation, operative mortality was highest in patients without preoperative coronary angiography and appropriate management of their native coronary artery disease and graft disease (odds ratio, 5.36; 95% confidence interval, 1.68-17.0; P=0.002). Nearly all the intimal dissection tears were located at sites of previous surgical trauma. Most of the ascending aortas that had dissected initially had a diameter≥40 mm with histological evidence of medial degeneration in resected tissue samples. CONCLUSIONS In patients who have undergone previous cardiac surgery, preexisting aortic wall pathology contributes to AAD with typical intimal damage at sites of mechanical trauma. The operative mortality was the highest in patients with previous CABG in comparison with patients with non-CABG procedures. Preoperative coronary angiography and operative management of native coronary and graft disease were significantly associated with outcome in patients with previous CABG.
Resumo:
BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.