214 resultados para PERCUTANEOUS-ABSORPTION
Resumo:
OBJECTIVES This study sought to determine whether high intestinal cholesterol absorption represents a cardiovascular risk factor and to link ABCG8 and ABO variants to cardiovascular disease (CVD). BACKGROUND Plant sterol-enriched functional foods are widely used for cholesterol lowering. Their regular intake yields a 2-fold increase in circulating plant sterol levels that equally represent markers of cholesterol absorption. Variants in ABCG8 and ABO have been associated with circulating plant sterol levels and CVD, thereby suggesting atherogenic effects of plant sterols or of cholesterol uptake. METHODS The cholestanol-to-cholesterol ratio (CR) was used as an estimate of cholesterol absorption because it is independent of plant sterols. First, we investigated the associations of 6 single nucleotide polymorphisms in ABCG8 and ABO with CR in the LURIC (LUdwisghafen RIsk and Cardiovascular health study) and the YFS (Young Finns Study) cohorts. Second, we conducted a systematic review and meta-analysis to investigate whether CR might be related to CVD. RESULTS In LURIC, the minor alleles of rs4245791 and rs4299376 and the major alleles of rs41360247, rs6576629, and rs4953023 of the ABCG8 gene and the minor allele of rs657152 of the ABO gene were significantly associated with higher CR. Consistent results were obtained for rs4245791, rs4299376, rs6576629, and rs4953023 in YFS. The meta-analysis, including 6 studies and 4,362 individuals, found that CR was significantly increased in individuals with CVD. CONCLUSIONS High cholesterol absorption is associated with risk alleles in ABCG8 and ABO and with CVD. Harm caused by elevated cholesterol absorption rather than by plant sterols may therefore mediate the relationships of ABCG8 and ABO variants with CVD.
Resumo:
BACKGROUND The effectiveness and durability of endovascular revascularization therapies for chronic critical limb ischemia (CLI) are challenged by the extensive burden of infrapopliteal arterial disease and lesion-related characteristics (e.g., severe calcification, chronic total occlusions), which frequently result in poor clinical outcomes. While infrapopliteal vessel patency directly affects pain relief and wound healing, sustained patency and extravascular care both contribute to the ultimate "patient-centric" outcomes of functional limb preservation, mobility and quality of life (QoL). METHODS/DESIGN IN.PACT DEEP is a 2:1 randomized controlled trial designed to assess the efficacy and safety of infrapopliteal arterial revascularization between the IN.PACT Amphirion™ paclitaxel drug-eluting balloon (IA-DEB) and standard balloon angioplasty (PTA) in patients with Rutherford Class 4-5-6 CLI. DISCUSSION This multicenter trial has enrolled 358 patients at 13 European centers with independent angiographic core lab adjudication of the primary efficacy endpoint of target lesion late luminal loss (LLL) and clinically driven target lesion revascularization (TLR) in major amputation-free surviving patients through 12-months. An independent wound core lab will evaluate all ischemic wounds to assess the extent of healing and time to healing at 1, 6, and 12 months. A QoL questionnaire including a pain scale will assess changes from baseline scores through 12 months. A Clinical Events Committee and Data Safety Monitoring Board will adjudicate the composite primary safety endpoints of all-cause death, major amputation, and clinically driven TLR at 6 months and other trial endpoints and supervise patient safety throughout the study. All patients will be followed for 5 years. A literature review is presented of the current status of endovascular treatment of CLI with drug-eluting balloon and standard PTA. The rationale and design of the IN.PACT DEEP Trial are discussed. IN.PACT DEEP is a milestone, prospective, randomized, robust, independent core lab-adjudicated CLI trial that will evaluate the role of a new infrapopliteal revascularization technology, the IA-DEB, compared to PTA. It will assess the overall impact on infrapopliteal artery patency, limb salvage, wound healing, pain control, QoL, and patient mobility. The 1-year results of the adjudicated co-primary and secondary endpoints will be available in 2014. TRIAL REGISTRATION NCT00941733
Resumo:
BACKGROUND To investigate the performance of the MI Sxscore in a multicentre randomised trial of patients undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS The MI Sxscore was prospectively determined among 1132 STEMI patients enrolled into the COMFORTABLE AMI trial, which randomised patients to treatment with bare-metal (BMS) or biolimus-eluting (BES) stents. Patient- (death, myocardial infarction, any revascularisation) and device-oriented (cardiac death, target-vessel MI, target lesion revascularisation) major adverse cardiac events (MACEs) were compared across MI Sxscore tertiles and according to stent type. The median MI SXscore was 14 (IQR: 9-21). Patients were divided into tertiles of Sxscorelow (≤10), Sxscoreintermediate (11-18) and Sxscorehigh (≥19). At 1year, patient-oriented MACE occurred in 15% of the Sxscorehigh, 9% of the Sxscoreintermediate and 5% of the Sxscorelow tertiles (p<0.001), whereas device-oriented MACE occurred in 8% of the Sxscorehigh, 6% of the Sxscoreintermediate and 4% of the Sxscorelow tertiles (p=0.03). Addition of the MI Sxscore to the TIMI risk score improved prediction of patient- (c-statistic value increase from 0.63 to 0.69) and device-oriented MACEs (c-statistic value increase from 0.65 to 0.70). Differences in the risk for device-oriented MACE between BMS and BES were evident among Sxscorehigh (13% vs. 4% HR 0.33 (0.15-0.74), p=0.007 rather than those in Sxscorelow: 4% vs. 3% HR 0.68 (0.24-1.97), p=0.48) tertiles. CONCLUSIONS The MI Sxscore allows risk stratification of patient- and device-oriented MACEs among patients undergoing PPCI. The addition of the MI Sxscore to the TIMI risk score is of incremental prognostic value among patients undergoing PPCI for treatment of STEMI.
Resumo:
Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population. Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years. Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.
Resumo:
Aims: The aim of this study was to identify predictors of adverse events among patients with ST-elevation myocardial infarction (STEMI) undergoing contemporary primary percutaneous coronary intervention (PCI). Methods and results: Individual data of 2,655 patients from two primary PCI trials (EXAMINATION, N=1,504; COMFORTABLE AMI, N=1,161) with identical endpoint definitions and event adjudication were pooled. Predictors of all-cause death or any reinfarction and definite stent thrombosis (ST) and target lesion revascularisation (TLR) outcomes at one year were identified by multivariable Cox regression analysis. Killip class III or IV was the strongest predictor of all-cause death or any reinfarction (OR 5.11, 95% CI: 2.48-10.52), definite ST (OR 7.74, 95% CI: 2.87-20.93), and TLR (OR 2.88, 95% CI: 1.17-7.06). Impaired left ventricular ejection fraction (OR 4.77, 95% CI: 2.10-10.82), final TIMI flow 0-2 (OR 1.93, 95% CI: 1.05-3.54), arterial hypertension (OR 1.69, 95% CI: 1.11-2.59), age (OR 1.68, 95% CI: 1.41-2.01), and peak CK (OR 1.25, 95% CI: 1.02-1.54) were independent predictors of all-cause death or any reinfarction. Allocation to treatment with DES was an independent predictor of a lower risk of definite ST (OR 0.35, 95% CI: 0.16-0.74) and any TLR (OR 0.34, 95% CI: 0.21-0.54). Conclusions: Killip class remains the strongest predictor of all-cause death or any reinfarction among STEMI patients undergoing primary PCI. DES use independently predicts a lower risk of TLR and definite ST compared with BMS. The COMFORTABLE AMI trial is registered at: http://www.clinicaltrials.gov/ct2/show/NCT00962416. The EXAMINATION trial is registered at: http://www.clinicaltrials.gov/ct2/show/NCT00828087.
Resumo:
A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (−210 to 0 ‰ for δ D and −27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.
Resumo:
BACKGROUND Up to 40% of ischaemic strokes are cryptogenic. A strong association between cryptogenic stroke and the prevalence of patent foramen ovale (PFO) suggests paradoxical embolism via PFO as a potential cause. Randomized trials failed to demonstrate superiority of PFO closure over medical therapy. METHODS AND RESULTS Randomized trials comparing percutaneous PFO closure against medical therapy or devices head-to-head published or presented by March 2013 were identified through a systematic search. We performed a network meta-analysis to determine the effectiveness and safety of PFO closure with different devices when compared with medical therapy. We included four randomized trials (2963 patients with 9309 patient-years). Investigated devices were Amplatzer (AMP), STARFlex (STF), and HELEX (HLX). Patients allocated to PFO closure with AMP were less likely to experience a stroke than patients allocated to medical therapy [rate ratio (RR) 0.39; 95% CI: 0.17-0.84]. No significant differences were found for STF (RR 1.01; 95% CI: 0.44-2.41), and HLX (RR, 0.71; 95% CI: 0.17-2.78) when compared with medical therapy. The probability to be best in preventing strokes was 77.1% for AMP, 20.9% for HLX, 1.7% for STF, and 0.4% for medical therapy. No significant differences were found for transient ischaemic attack and death. The risk of new-onset atrial fibrillation was more pronounced for STF (RR 7.67; 95% CI: 3.25-19.63), than AMP (RR 2.14; 95% CI: 1.00-4.62) and HLX (RR 1.33; 95%-CI 0.33-4.50), when compared with medical therapy. CONCLUSIONS The effectiveness of PFO closure depends on the device used. PFO closure with AMP appears superior to medical therapy in preventing strokes in patients with cryptogenic embolism.
Resumo:
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Resumo:
Aims: To compare clinical outcome of Amplatzer PFO (APFO) to Cardia PFO (CPFO) occluder. Percutaneous patent foramen ovale (PFO) closure prevents stroke recurrence in stroke due to paradoxical embolism. Methods and results: The primary endpoint was a composite of stroke, TIA, or peripheral embolism at follow-up. The secondary endpoint was residual shunt. Outcome was compared among 934 (APFO: 712; CPFO: 222) patients, and in 297 propensity score-matched patients. The primary endpoint occurred in 29 patients (0.71/100 patient-years): four (2%) with the CPFO (0.31/100 patient-years), and 25 (4%) with the APFO (0.89/100 patient-years) (p=0.20). Residual shunt at six months was more frequent with the CPFO (31% versus 9%, p<0.001). No differences in residual shunts were seen at the last available echocardiographic follow-up (9±18 months): APFO 11%, CPFO 14%, p=0.22. Conclusions: This study suggests that PFO closure with APFO or CPFO is equally effective for the prevention of recurrent events. Residual shunt was more frequent at six months with CPFO, but was similar to APFO at later follow-up.
Resumo:
INTRODUCTION Anemia and renal impairment are important co-morbidities among patients with coronary artery disease undergoing Percutaneous Coronary Intervention (PCI). Disease progression to eventual death can be understood as the combined effect of baseline characteristics and intermediate outcomes. METHODS Using data from a prospective cohort study, we investigated clinical pathways reflecting the transitions from PCI through intermediate ischemic or hemorrhagic events to all-cause mortality in a multi-state analysis as a function of anemia (hemoglobin concentration <120 g/l and <130 g/l, for women and men, respectively) and renal impairment (creatinine clearance <60 ml/min) at baseline. RESULTS Among 6029 patients undergoing PCI, anemia and renal impairment were observed isolated or in combination in 990 (16.4%), 384 (6.4%), and 309 (5.1%) patients, respectively. The most frequent transition was from PCI to death (6.7%, 95% CI 6.1-7.3), followed by ischemic events (4.8%, 95 CI 4.3-5.4) and bleeding (3.4%, 95% CI 3.0-3.9). Among patients with both anemia and renal impairment, the risk of death was increased 4-fold as compared to the reference group (HR 3.9, 95% CI 2.9-5.4) and roughly doubled as compared to patients with either anemia (HR 1.7, 95% CI 1.3-2.2) or renal impairment (HR 2.1, 95% CI 1.5-2.9) alone. Hazard ratios indicated an increased risk of bleeding in all three groups compared to patients with neither anemia nor renal impairment. CONCLUSIONS Applying a multi-state model we found evidence for a gradient of risk for the composite of bleeding, ischemic events, or death as a function of hemoglobin value and estimated glomerular filtration rate at baseline.