161 resultados para MINIMALLY INVASIVE NEUROSURGERY
Resumo:
We present cases of 2 pregnant patients with early-stage cervical cancer who have undergone indocyanine green (ICG) sentinel lymph node (SLN) mapping followed by laparoscopic SLN biopsy, pelvic lymphadenectomy, and cervical conization. Eight milliliters of ICG were injected in the 4 quadrants of the cervix after having obtained an adequate pneumoperitoneum and having inspected the abdominal cavity. SLNs were identified in both hemipelvises in both patients. In the final pathologic analysis, both SLNs and non-SLNs were negative for metastatic disease. No adverse events from ICG injection were recorded. ICG SLN mapping seems to be feasible in pregnant cervical cancer patients.
Resumo:
Heavy menstrual bleeding (HMB) has significant adverse effects on the quality of life of many women, placing an economic burden on both health services and society at large. Thus, it is essential that all women with HMB have easy access to the proper diagnostic and therapeutic work-up in an outpatient fashion, avoiding the more time-consuming inpatient management. This new outpatient approach for HMB is one of the latest development of gynecological practice and can offer both diagnostic and therapeutic procedures. This manuscript aims to show the current possibilities of the modern management of HMB, which can be safely and effectively accomplished in the outpatient setting: global and directed endometrial biopsy, levonorgestrel intrauterine system insertion as well as minimally invasive surgical procedures (encompassing a variety of operative hysteroscopic procedures and second-generation endometrial ablation) are described below.
Resumo:
We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.
Resumo:
Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.
Resumo:
Three groups of Atlantic salmon were kept at a constant temperature of 4, 10 and 14 °C. The adipose fins were removed; six fish/group were sampled at 11 subsequent time points post-clipping. Samples were prepared for histopathological examination to study the course of re-epithelization. A score sheet was developed to assess the regeneration of epidermal and dermal cell types. Wounds were covered by a thin epidermal layer between 4 and 6 h post-clipping at 10 and 14 °C. In contrast, wound closure was completed between 6 and 12 h in fish held at a constant temperature of 4 °C. By 18 h post-clipping, superficial cells, cuboidal cells, prismatic basal cells and mucous cells were discernible in all temperature groups, rapidly progressing towards normal epidermal structure and thickness. Within the observation period, only minor regeneration was found in the dermal layers. A positive correlation between water temperature and healing rates was established for the epidermis. The rapid wound closure rate, epidermal normalization and the absence of inflammatory reaction signs suggest that adipose fin clipping under anaesthesia constitutes a minimally invasive method that may be used to mark large numbers of salmon presmolts without compromising fish welfare.
Resumo:
Nucleus pulposus replacements have been subjected to highly controversial discussions over the last 40 years. Their use has not yet resulted in a positive outcome to treat herniated disc or degenerated disc disease. The main reason is that not a single implant or tissue replacement was able to withstand the loads within an intervertebral disc. Here, we report on the development of a photo-polymerizable poly(ethylene glycol)dimethacrylate nano-fibrillated cellulose composite hydrogel which was tuned according to native tissue properties. Using a customized minimally-invasive medical device to inject and photopolymerize the hydrogel insitu, samples were implanted through an incision of 1 mm into an intervertebral disc of a bovine organ model to evaluate their long-term performance. When implanted into the bovine disc model, the composite hydrogel implant was able to significantly re-establish disc height after surgery (p < 0.0025). The height was maintained after 0.5 million loading cycles (p < 0.025). The mechanical resistance of the novel composite hydrogel material combined with the minimally invasive implantation procedure into a bovine disc resulted in a promising functional orthopedic implant for the replacement of the nucleus pulposus.
Resumo:
CONTEXT Most patients with neuro-urological disorders require life-long medical care. The European Association of Urology (EAU) regularly updates guidelines for the diagnosis and treatment of these patients. OBJECTIVE To provide a summary of the 2015 updated EAU Guidelines on Neuro-Urology. EVIDENCE ACQUISITION Structured literature searches in several databases were carried out to update the 2014 guidelines. Levels of evidence and grades of recommendation were assigned where possible. EVIDENCE SYNTHESIS Neurological disorders often cause urinary tract, sexual, and bowel dysfunction. Most neuro-urological patients need life-long care for optimal life expectancy and quality of life. Timely diagnosis and treatment are essential to prevent upper and lower urinary tract deterioration. Clinical assessment should be comprehensive and usually includes a urodynamic investigation. The neuro-urological management must be tailored to the needs of the individual patient and may require a multidisciplinary approach. Sexuality and fertility issues should not be ignored. Numerous conservative and noninvasive possibilities of management are available and should be considered before a surgical approach is chosen. Neuro-urological patients require life-long follow-up and particular attention has to be paid to this aspect of management. CONCLUSIONS The current EAU Guidelines on Neuro-Urology provide an up-to-date overview of the available evidence for adequate diagnosis, treatment, and follow-up of neuro-urological patients. PATIENT SUMMARY Patients with a neurological disorder often suffer from urinary tract, sexual, and bowel dysfunction and life-long care is usually necessary. The update of the EAU Guidelines on Neuro-Urology, summarized in this paper, enables caregivers to provide optimal support to neuro-urological patients. Conservative, noninvasive, or minimally invasive approaches are often possible.
Resumo:
Peripheral arteriovenous malformations (AVM) remain most challenging among various congenital vascular malformations to be treated. Here we present three illustrative patients with Yakes type IIIb and type IV AVM at the plantar aspect of the foot who were successfully treated by minimally invasive embolization. The value of the Yakes AVM classification system to guide the therapeutic decision making by directing specific therapeutic procedures to specific AVM types defined by their angioarchitecture is demonstrated. Direct percutaneous AVM puncture with coiling of aneurysmal outflow vein and subsequent ethanol embolization is shown. Finally, the report illustrates that several AVM types can coexist.
Resumo:
OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.
Resumo:
BACKGROUND: Accurate projection of implanted subdural electrode contacts in presurgical evaluation of pharmacoresistant epilepsy cases by invasive EEG is highly relevant. Linear fusion of CT and MRI images may display the contacts in the wrong position due to brain shift effects. OBJECTIVE: A retrospective study in five patients with pharmacoresistant epilepsy was performed to evaluate whether an elastic image fusion algorithm can provide a more accurate projection of the electrode contacts on the pre-implantation MRI as compared to linear fusion. METHODS: An automated elastic image fusion algorithm (AEF), a guided elastic image fusion algorithm (GEF), and a standard linear fusion algorithm (LF) were used on preoperative MRI and post-implantation CT scans. Vertical correction of virtual contact positions, total virtual contact shift, corrections of midline shift and brain shifts due to pneumencephalus were measured. RESULTS: Both AEF and GEF worked well with all 5 cases. An average midline shift of 1.7mm (SD 1.25) was corrected to 0.4mm (SD 0.8) after AEF and to 0.0mm (SD 0) after GEF. Median virtual distances between contacts and cortical surface were corrected by a significant amount, from 2.3mm after LF to 0.0mm after AEF and GEF (p<.001). Mean total relative corrections of 3.1 mm (SD 1.85) after AEF and 3.0mm (SD 1.77) after GEF were achieved. The tested version of GEF did not achieve a satisfying virtual correction of pneumencephalus. CONCLUSION: The technique provided a clear improvement in fusion of pre- and post-implantation scans, although the accuracy is difficult to evaluate.