285 resultados para Coronary Artery Disease
Resumo:
INTRODUCTION: Nebivolol, a highly selective beta1-adrenergic receptor-blocker, increases basal and stimulated endothelial nitric oxide (NO)-release. It is unknown, whether coronary perfusion is improved by the increase in NO availability. Therefore, we sought to evaluate the effect of nebivolol on coronary flow reserve (CFR) and collateral flow. METHODS: Doppler-flow wire derived coronary flow velocity measurements were obtained in ten controls and eight patients with coronary artery disease (CAD) at rest and after intracoronary nebivolol. CFR was defined as maximal flow during adenosine-induced hyperemia divided by resting flow. In the CAD group, collateral flow was determined after dilatation of a flow-limiting coronary stenosis. Collateral flow index (CFI) was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS: CFR at rest was 3.0+/-0.6 in controls and 2.1+/-0.4 in CAD patients. After intracoronary doses of 0.1, 0.25, and 0.5 mg nebivolol, CFR increased to 3.4+/-0.7, 3.9+/-0.9, and 4.0+/-0.1 (p<0.01) in controls, and to 2.3+/-0.7, 2.6+/-0.9, and 2.6+/-0.5 (p<0.05) in CAD patients. CFI decreased significantly with intracoronary nebivolol and correlated to changes in heart rate (r=0.75, p<0.001) and rate-pressure product (r=0.59, p=0.001). DISCUSSION: Intracoronary nebivolol is associated with a significant increase in CFR due to reduction in resting flow (controls), or due to an increase in maximal coronary flow (CAD patients). CFI decreased with nebivolol parallel to the reduction in myocardial oxygen consumption.
Resumo:
BACKGROUND: Paclitaxel-eluting stents (PES) have been shown to reduce the rate of restenosis and the need for repeated revascularization procedures compared with bare metal stents. However, long-term effects of paclitaxel on vascular function are unknown. The purpose of the present study was to assess coronary vasomotor response to exercise after paclitaxel-eluting stent implantation. METHODS: Coronary vasomotion was evaluated by biplane quantitative coronary angiography at rest and during supine bicycle exercise in 27 patients with coronary artery disease. Twelve patients were treated with a bare metal stent (controls), and fifteen patients with a paclitaxel-eluting stent. All patients were restudied 6+/-2 (range 2-12) months after stent implantation. Minimal luminal diameter, stent diameter, proximal, distal and a reference vessel diameter were determined. RESULTS: Reference vessels showed exercise-induced vasodilation in both groups (+20+/-5% controls; +26+/-3% PES group). Vasomotion within the stented vessel segments was abolished. In the controls, the adjacent segments proximal and distal to the stent showed exercise-induced vasodilation (+17+/-3% and +24+/-4%). In contrast, there was exercise-induced vasoconstriction of the proximal and distal vessel segments adjacent to the paclitaxel-eluting stent (-13+/-6% and -18+/-4%; p<0.005). After sublingual nitroglycerin, the proximal and distal vessel segments dilated in both groups. Exercise-induced vasoconstriction adjacent to paclitaxel-eluting stent correlated inversely with the time interval after stent implantation. CONCLUSIONS: Paclitaxel-eluting stent implantation is associated with exercise-induced vasoconstriction in the persistent region suggesting endothelial dysfunction as the underlying mechanism. Improvement of vascular function occurs over time, indicating delayed vascular healing.
Resumo:
AIMS: We investigated whether myeloid-related protein 8/14 complex (MRP8/14) expressed by infiltrating monocytes and granulocytes may represent a mediator and early biomarker of acute coronary syndromes (ACS). METHODS AND RESULTS: Immunohistochemistry of coronary thrombi was done in 41 ACS patients. Subsequently, levels of MRP8/14 were assessed systemically in 75 patients with ACS and culprit lesions, with stable coronary artery disease (CAD), or with normal coronary arteries. In a subset of patients, MRP8/14 was measured systemically and at the site of coronary occlusion. Macrophages and granulocytes, but not platelets stained positive for MRP8/14 in 76% of 41 thrombi patients. In ACS, local MRP8/14 levels [22.0 (16.2-41.5) mg/L] were increased when compared with systemic levels [13.4 (8.1-14.7) mg/L, P = 0.03]. Systemic levels of MRP8/14 were markedly elevated [15.1 (12.1-21.8) mg/L, P = 0.001] in ACS when compared with stable CAD [4.6 (3.5-7.1) mg/L] or normals [4.8 (4.0-6.3) mg/L]. Using a cut-off level of 8 mg/L, MRP8/14 but not myoglobin or troponin, identified ACS presenting within 3 h from symptom onset. CONCLUSION: In ACS, MRP8/14 is markedly expressed at the site of coronary occlusion by invading phagocytes. The occurrence of elevated MRP8/14 in the systemic circulation prior to markers of myocardial necrosis makes it a prime candidate for the detection of unstable plaques and management of ACS.
Resumo:
We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.
Resumo:
BACKGROUND: The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. METHODS: On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. RESULTS: CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. CONCLUSIONS: In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure.
Resumo:
Determining whether hypoplasia of a coronary artery has caused or contributed to death is often complicated by an absence of histologic evidence of myocardial ischemia in the area of the heart supplied by the affected artery and also by the lack of data for assessing coronary artery size at autopsy. A 45-year-old woman is reported who collapsed and died and who was found at autopsy to have a dominant, small-caliber, right coronary artery, with acute and chronic ischemic changes in the posterior interventricular septum supplied by the diminutive vessel. This case provides evidence that small-caliber coronary arteries may be associated with a lethal outcome. Given the difficulties that may occur in determining whether there is a causal link between small coronary artery caliber and death, it is possible that this may be an underdiagnosed cause of sudden cardiac death, rather than a coincidental finding of minimal significance.
Resumo:
Pulmonary embolism is very rarely reported early after cardiac surgery, most probably due to full heparinisation during cardiopulmonary bypass. We report a 66-year-old man without thromboembolic history who presented three days after a coronary artery bypass grafting procedure with acute dyspnoea and haemodynamic instability. A CT scan confirmed paracentral bilateral pulmonary embolism requiring an urgent and successful embolectomy. Review of the literature confirms that pulmonary embolism may occur in up to 3% of post-cardiopulmonary bypass patients. The possibility of pulmonary embolism must be taken into consideration in post-cardiopulmonary bypass patients with acute onset of chest pain and respiratory insufficiency.
Resumo:
BACKGROUND: We examined whether vascular smooth muscle (VSMC) or endothelial cell (EC) migration from internal mammary artery (MA) differed from VSMC or EC migration from saphenous vein (SV). METHODS AND RESULTS: Migration to PDGF-BB (1-10 ng/ml) was lower in VSMC from MA than SV; however, attachment, movement without chemokine, and chemokinesis were identical. Unlike VSMC, migration of EC was similar in response to several mediators. Expression of PDGF receptor-beta was lower in VSMC from MA than SV, while alpha-receptor expression was higher. PDGF-BB-induced RhoA activity was lower in MA than SV, while basal activity was identical. Rosuvastatin and hydroxyfasudil impaired PDGF-BB-induced migration of VSMC from MA and SV. Mevalonate and geranylgeranylpyrophosphate rescued inhibition by rosuvastatin. PDGF-BB induced less stress fiber formation in VSMC from MA than SV. A dominant negative RhoA mutant inhibited stress fiber formation to PDGF-BB, while a constitutively active mutant resulted in maximal stress fiber formation in MA and SV. Rosuvastatin and hydroxyfasudil impaired PDGF-BB-induced stress fiber formation in MA and SV. CONCLUSIONS: VSMC migration to PDGF-BB is lower in MA than SV, which is at least in part related to lower activity of the Rho/ROCK pathway.
Resumo:
BACKGROUND AND OBJECTIVES: Data suggest that atorvastatin may be nephroprotective. This subanalysis of the Treating to New Targets study investigated how intensive lipid lowering with 80 mg of atorvastatin affects renal function when compared with 10 mg in patients with coronary heart disease. DESIGN, SETTING, PARTICIPANTS, ; MEASUREMENTS: A total of 10,001 patients with coronary heart disease and LDL cholesterol levels of <130 mg/dl were randomly assigned to double-blind therapy with 10 or 80 mg/d atorvastatin. Estimated GFR using the Modification of Diet in Renal Disease equation was compared at baseline and at the end of follow-up in 9656 participants with complete renal data. RESULTS: Mean estimated GFR at baseline was 65.6 +/- 11.4 ml/min per 1.73 m2 in the 10-mg group and 65.0 +/- 11.2 ml/min per 1.73 m2 in the 80-mg group. At the end of follow-up (median time to final creatinine measurement 59.5 months), mean change in estimated GFR showed an increase of 3.5 +/- 0.14 ml/min per 1.73 m2 with 10 mg and 5.2 +/- 0.14 ml/min per 1.73 m2 with 80 mg (P < 0.0001 for treatment difference). In the 80-mg arm, estimated GFR improved to > or = 60 ml/min per 1.73 m2 in significantly more patients and declined to < 60 ml/min per 1.73 m2 in significantly fewer patients than in the 10-mg arm. CONCLUSIONS: The expected 5-yr decline in renal function was not observed. Estimated GFR improved in both treatment groups but was significantly greater with 80 mg than with 10 mg, suggesting this benefit may be dosage related.
Resumo:
OBJECTIVE: To examine by secondary analysis of the Treating to New Targets (TNT) study whether the benefits of intensive versus standard levels of lipid lowering are equally applicable to women. METHODS: A total of 10 001 patients (1902 women) with stable coronary heart disease (CHD) were randomised to double-blind treatment with atorvastatin 10 or 80 mg/day for a median follow-up of 4.9 years. RESULTS: In women and men, intensive treatment with atorvastatin 80 mg significantly reduced the rate of major cardiovascular events compared with atorvastatin 10 mg. Among women, the relative and absolute reductions were 27% and 2.7%, respectively (hazard ratio (HR) = 0.73, 95% confidence interval (CI) 0.54 to 1.00, p = 0.049). In men, the corresponding rate reductions were 21% and 2.2% (HR = 0.79, 95% CI 0.69 to 0.91, p = 0.001). The number needed to treat value (to prevent one cardiovascular event over 4.9 years compared with patients treated with atorvastatin 10 mg) for atorvastatin 80 mg was 29 for women and 30 for men. Rates of death of non-cardiovascular origin in the atorvastatin 80 mg and atorvastatin 10 mg were 3.6% and 1.6%, respectively (p = 0.004) among women, and 2.8% and 3.1% (p = 0.47) among men. CONCLUSION: Intensive lipid-lowering treatment with atorvastatin 80 mg produced significant reductions in relative risk for major cardiovascular events compared with atorvastatin 10 mg in both women and men with stable CHD.
Resumo:
PURPOSE: To report the authors' initial experience with carotid artery stent-grafts in a comparatively large patient series for the treatment of acute bleeding and impending rupture or the prevention of distal embolization. MATERIALS AND METHODS: This retrospective study was approved by the institutional review boards and performed according to HIPPA standards. Twenty-five patients were treated with 27 carotid artery stent-grafts (Gore Viabahn, n = 10; Bard Fluency, n = 9; polytetrafluoroethylene-covered Palmaz, n = 5; and Wallgraft, n = 3). Thirteen stent-grafts were placed in patients with carotid blow-out syndrome (including three patients with carotid-airway fistula), 12 in patients with either pseudoaneurysm (n = 9) or true aneurysm (n = 3), and two in patients with intractable high-grade bare stent restenosis. RESULTS: The technical success rate was 100% (27 of 27 cases). No acute procedural transient ischemic attacks or strokes occurred. Procedural dissections occurred in two of the 27 cases (7.4%). Short-term complications occurred in three of the 27 cases (11%) (repeat hemorrhage, n = 2; common carotid artery occlusion, n = 1). The overall patient mortality rate was 36% (nine of 25 patients, all with carotid blow-out syndrome). Six-month follow-up in 15 of the 16 living patients demonstrated widely patent stent-grafts. Two patients with pseudoaneurysm also demonstrated patent stents at 18- and 33-month follow-up. CONCLUSIONS: Stent-grafts may be useful in the treatment of carotid artery bleeding syndrome, aneurysm, and stenosis, with a high procedural success rate in selected cases. The results of mid-term follow-up are encouraging, but results of long-term follow-up must be evaluated in future studies.
Resumo:
BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.