285 resultados para ultrasound guided nerveblock


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound is an emerging new imaging and guiding technique for diagnostic or therapeutic interventional pain procedures. Advantages are the real time monitoring of the targeted structures, the placement of the instruments and the visualization of local anaesthetic spread without exposing patients and personal to radiation. Pain specialists need a large anatomical knowledge and training to use the new method safely and distinctively. The increasing published data available and the personal experience of the authors suggest a potential usefulness in interventional pain therapy, but also limitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, our study group demonstrated the usefulness of ultrasonographic guidance in ilioinguinal/iliohypogastric nerve blocks in children. As a consequence, we designed a follow-up study to evaluate the optimal volume of local anesthetic for this regional anesthetic technique. Using a modified step-up-step-down approach, with 10 children in each study group, a starting dose of 0.2 mL/kg of 0.25% levobupivacaine was administered to perform an ilioinguinal/iliohypogastric nerve block under ultrasonographic guidance. After each group of 10 patients, the results were analyzed, and if all blocks were successful, the volume of local anesthetic was decreased by 50%, and a further 10 patients were enrolled into the study. Failure to achieve a 100% success rate within a group subjected patients to an automatic increase of half the previous volume reduction to be used in the subsequent group. Using 0.2 and 0.1 mL/kg of 0.25% levobupivacaine, the success rate was 100%. With a volume of 0.05 mL/kg of 0.25% levobupivacaine, 4 of 10 children received additional analgesia because of an inadequate block. Therefore, according to the protocol, the amount was increased to 0.075 mL/kg of 0.25% levobupivacaine, where the success rate was again 100%. We conclude that ultrasonographic guidance for ilioinguinal/iliohypogastric nerve blocks in children allowed a reduction of the volume of local anesthetic to 0.075 mL/kg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We estimated the diagnostic accuracy of ultrasound detrusor thickness measurement for BOO and investigated whether this method can replace PFS for the diagnosis of BOO in some patients with lower urinary tract symptoms. MATERIALS AND METHODS: Detrusor thickness was measured by linear ultrasound (7.5 MHz) at a filling volume of greater than 50% of cystometric capacity in 102 men undergoing PFS for LUTS. All patients with prior treatment for bladder outlet obstruction and those with underlying neurological disorders were excluded from analysis. Detrusor thickness was correlated with PFS data. Obstruction was defined according to the Abrams-Griffiths nomogram. RESULTS: Detrusor thickness was significantly higher (p <0.0001) in obstructed (61 cases, median detrusor thickness 2.7 mm, IQR 2.4 to 3.3) compared to unobstructed (18 cases, median detrusor thickness 1.7 mm, IQR 1.5 to 2) as well as equivocal (23 cases, median detrusor thickness 1.8 mm, IQR 1.5 to 2.2) cases. A weak to medium Spearman correlation was found between detrusor thickness and PFS parameters. For a diagnosis of BOO, detrusor thickness of 2.9 mm or greater had a positive predictive value of 100%, a negative predictive value of 54%, specificity of 100% and sensitivity of 43%. ROC analysis revealed that detrusor thickness had a high predictive value for BOO with an AUC of 0.88 (95% CI 0.81-0.94). CONCLUSIONS: In men with LUTS without prior treatment and/or neurological disorders, ultrasonographically assessed detrusor thickness 2.9 mm or greater has a high predictive value for BOO and can replace PFS for the diagnosis of BOO. However, this cutoff value needs to be validated in a larger study population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invasive "body-opening" autopsy represents the traditional means of postmortem investigation in humans. However, modern cross-sectional imaging techniques can supplement and may even partially replace traditional autopsy. Computed tomography (CT) is the imaging modality of choice for two- and three-dimensional documentation and analysis of autopsy findings including fracture systems, pathologic gas collections (eg, air embolism, subcutaneous emphysema after trauma, hyperbaric trauma, decomposition effects), and gross tissue injury. Various postprocessing techniques can provide strong forensic evidence for use in legal proceedings. Magnetic resonance (MR) imaging has had a greater impact in demonstrating soft-tissue injury, organ trauma, and nontraumatic conditions. However, the differences in morphologic features and signal intensity characteristics seen at antemortem versus postmortem MR imaging have not yet been studied systematically. The documentation and analysis of postmortem findings with CT and MR imaging and postprocessing techniques ("virtopsy") is investigator independent, objective, and noninvasive and will lead to qualitative improvements in forensic pathologic investigation. Future applications of this approach include the assessment of morbidity and mortality in the general population and, perhaps, routine screening of bodies prior to burial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous dilatational tracheostomy (PDT) is a frequently conducted procedure in critically ill patients. Bronchoscopic guidance of PDT is generally recommended to minimize the risk of unintentional tracheal injury. We present a case of tracheal tear and tension pneumothorax, a rare but potentially life-threatening complication, during continuously bronchoscopy-guided PDT. Sealing the large tracheal air fistula with the cuff of an endotracheal tube helped bridge time to definitive surgical repair in our patient. Bronchoscopic guidance may minimize, but cannot completely eliminate, the risk of tracheal injury during PDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the clinical outcome of horizontal ridge augmentation using autogenous block grafts covered with an organic bovine bone mineral (ABBM) and a bioabsorbable collagen membrane. MATERIAL AND METHODS: In 42 patients with severe horizontal bone atrophy, a staged approach was chosen for implant placement following horizontal ridge augmentation. A block graft was harvested from the symphysis or retromolar area, and secured to the recipient site with fixation screws. The width of the ridge was measured before and after horizontal ridge augmentation. The block graft was subsequently covered with ABBM and a collagen membrane. Following a tension-free primary wound closure and a mean healing period of 5.8 months, the sites were re-entered, and the crest width was re-assessed prior to implant placement. RESULTS: Fifty-eight sites were augmented, including 41 sites located in the anterior maxilla. The mean initial crest width measured 3.06 mm. At re-entry, the mean width of the ridge was 7.66 mm, with a calculated mean gain of horizontal bone thickness of 4.6 mm (range 2-7 mm). Only minor surface resorption of 0.36 mm was observed from augmentation to re-entry. CONCLUSIONS: The presented technique of ridge augmentation using autogenous block grafts with ABBM filler and collagen membrane coverage demonstrated successful horizontal ridge augmentation with high predictability. The surgical method has been further simplified by using a resorbable membrane. The hydrophilic membrane was easy to apply, and did not cause wound infection in the rare instance of membrane exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2D-3D registration of pre-operative 3D volumetric data with a series of calibrated and undistorted intra-operative 2D projection images has shown great potential in CT-based surgical navigation because it obviates the invasive procedure of the conventional registration methods. In this study, a recently introduced spline-based multi-resolution 2D-3D image registration algorithm has been adapted together with a novel least-squares normalized pattern intensity (LSNPI) similarity measure for image guided minimally invasive spine surgery. A phantom and a cadaver together with their respective ground truths were specially designed to experimentally assess possible factors that may affect the robustness, accuracy, or efficiency of the registration. Our experiments have shown that it is feasible for the assessed 2D-3D registration algorithm to achieve sub-millimeter accuracy in a realistic setup in less than one minute.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Preoperative chemoradiotherapy is generally recommended for locally advanced esophageal cancer (clinical stage T3 or T4 or nodal positive disease) but not for early cancer (clinical stage T0 to T2, N0). EUS has been described as the most accurate method to distinguish between early and locally advanced stage in several studies. Recently however, the high accuracy of EUS (90% or higher) was questioned by some investigators. This raises the issue whether the results of studies focused on EUS accuracy may be directly translated into daily clinical practice. Aim & Methods: The aim of this retrospective analysis was to assess the accuracy of preoperative EUS to distinguish between early and locally advanced esophageal cancer in daily clinical practice outside a study setting. EUS was performed by several investigators, including trainees in one university hospital. For this purpose, EUS reports and patient files (medical and surgical) including histological reports of 300 consecutive pts with esophageal tumors were reviewed. In pts with adenocarcinoma or squamous cell cancer and surgical resection without previous radio-/chemotherapy, EUS tumor staging was compared with histological diagnosis. Results: Out of the 300 consecutive pts with esophageal tumor and EUS 102 pts had esophageal surgery after EUS-staging without any radio-/chemotherapy. In 93 pts oesophageal cancer was confirmed, whereas 9 had other tumors. The mean age was 65 years (range 27-89), sex ratio female:male was 1:3.2. To distinguish between early and late tumor stage, the accuracy was 85%. The sensitivity and specificity for early cancer was 59%, and 93%, respectively. The diagnostic accuracy for local tumor spread was 90%, 90%, 68%, 69%, 89% for pT0, pT1, pT2, pT3 and pT4 lesions, respectively. The overall accuracy for T-stage was 74%. For pN-positive staging the accuracy of EUS was 73%. Conclusion: In daily clinical practice, the accuracy of EUS in assessing esophageal tumor staging is lower than in specific studies focusing on EUS accuracy. Mainly early esophageal cancer stages were overstaged. Thus, the implementation of recommendations for diagnostic work-up of esophageal cancer patients resulting from highly specific studies should consider the appropriate clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image-guided, computer-assisted neurosurgery has emerged to improve localization and targeting, to provide a better anatomic definition of the surgical field, and to decrease invasiveness. Usually, in image-guided surgery, a computer displays the surgical field in a CT/MR environment, using axial, coronal or sagittal views, or even a 3D representation of the patient. Such a system forces the surgeon to look away from the surgical scene to the computer screen. Moreover, this kind of information, being pre-operative imaging, can not be modified during the operation, so it remains valid for guidance in the first stage of the surgical procedure, and mainly for rigid structures like bones. In order to solve the two constraints mentioned before, we are developing an ultrasoundguided surgical microscope. Such a system takes the advantage that surgical microscopy and ultrasound systems are already used in neurosurgery, so it does not add more complexity to the surgical procedure. We have integrated an optical tracking device in the microscope and an augmented reality overlay system with which we avoid the need to look away from the scene, providing correctly aligned surgical images with sub-millimeter accuracy. In addition to the standard CT and 3D views, we are able to track an ultrasound probe, and using a previous calibration and registration of the imaging, the image obtained is correctly projected to the overlay system, so the surgeon can always localize the target and verify the effects of the intervention. Several tests of the system have been already performed to evaluate the accuracy, and clinical experiments are currently in progress in order to validate the clinical usefulness of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study reports the secondary analysis of a randomized-controlled clinical trial designed to assess the efficacy of deproteinized bovine mineral and a collagen membrane in the treatment of intrabony defects. The specific aims of this report are (1) to analyse the radiographic bone changes 1 year after therapy and (2) to assess the association between radiographic defect angle and treatment outcomes. MATERIALS AND METHODS: Baseline and 12-month radiographs were collected from 120 patients with advanced chronic periodontitis from 10 centres in seven countries as part of a multi-centre clinical trial. All patients had at least one intrabony defect > or =3 mm in depth. The treatment consisted of simplified or modified papilla preservation flaps to access the defect. After debridement of the area, a deproteinized bovine mineral and a collagen membrane were applied in the test subjects, and omitted in the controls. Main outcome measures were radiographic bone fill and defect resolution 1 year after surgery. RESULTS: One hundred and twenty pairs of radiographs were obtained, of which 110 pairs were measurable (57 tests and 53 controls). One year after treatment, radiographic resolution of the intrabony component was significantly higher in the test group (3.2+/-1.7 mm) when compared with the controls (1.7+/-1.9 mm). Multivariate analysis indicated that the treatment and the baseline radiographic depth of the intrabony defect significantly influenced the radiographic bone fill of the intrabony defect 1 year following treatment. The percentage of resolution of the defect was influenced by the treatment provided and the baseline plaque score. The baseline radiographic defect angle did not show a significant impact on the clinical and radiographic outcomes. CONCLUSIONS: Regenerative periodontal surgery with a deproteinized bovine bone mineral and a collagen membrane offered additional benefits in terms of radiographic resolution of the intrabony defect and predictability of outcomes with respect to papilla preservation flaps alone.