174 resultados para PORTAL-VEIN THROMBOSIS
Resumo:
Aims: Newer-generation everolimus-eluting stents (EES) have been shown to improve clinical outcomes compared with early-generation sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) in patients undergoing percutaneous coronary intervention (PCI). Whether this benefit is maintained among patients with saphenous vein graft (SVG) disease remains controversial. Methods and results: We assessed cumulative incidence rates (CIR) per 100 patient years after inverse probability of treatment weighting to compare clinical outcomes. The pre-specified primary endpoint was the composite of cardiac death, myocardial infarction (MI), and target vessel revascularisation (TVR). Out of 12,339 consecutively treated patients, 288 patients (5.7%) underwent PCI of at least one SVG lesion with EES (n=127), SES (n=103) or PES (n=58). Up to four years, CIR of the primary endpoint were 58.7 for EES, 45.2 for SES and 45.6 for PES with similar adjusted risks between groups (EES vs. SES; HR 0.94, 95% CI: 0.55-1.60, EES vs. PES; HR 1.07, 95% CI: 0.60-1.91). Adjusted risks showed no significant differences between stent types for cardiac death, MI and TVR. Conclusions: Among patients undergoing PCI for SVG lesions, newer-generation EES have similar safety and efficacy to early-generation SES and PES during long-term follow-up to four years.
Resumo:
BACKGROUND The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. METHODS Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. RESULTS A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30-40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. CONCLUSIONS The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients.
Resumo:
OBJECTIVES The aim of this study was to analyze trigger activity in the long-term follow-up after left atrial (LA) linear ablation. BACKGROUND Interventional strategies for curative treatment of atrial fibrillation (AF) are targeted at the triggers and/or the maintaining substrate. After substrate modification using nonisolating linear lesions, the activity of triggers is unknown. METHODS With the LA linear lesion concept, 129 patients were treated using intraoperative ablation with minimal invasive surgical techniques. Contiguous radiofrequency energy-induced lesion lines involving the mitral annulus and the orifices of the pulmonary veins without isolation were placed under direct vision. RESULTS After a mean follow-up of 3.6 +/- 0.4 years, atrial ectopy, atrial runs, and reoccurrence of AF episodes were analyzed by digital 7-day electrocardiograms in 30 patients. Atrial ectopy was present in all patients. Atrial runs were present in 25 of 30 patients (83%), with a median number of 9 runs per patient/week (range 1 to 321) and a median duration of 1.2 s/run (range 0.7 to 25), without a significant difference in atrial ectopy and atrial runs between patients with former paroxysmal (n = 17) or persistent AF (n = 13). Overall, 87% of all patients were completely free from AF without antiarrhythmic drugs. CONCLUSIONS A detailed rhythm analysis late after specific LA linear lesion ablation shows that trigger activity remains relatively frequent but short and does not induce AF episodes in most patients. The long-term success rate of this concept is high in patients with paroxysmal or persistent AF.
Resumo:
AIMS In 1999 the consensus statement "living anatomy of the atrioventricular junctions" was published. With that new nomenclature the former posteroseptal accessory pathway (APs) are termed paraseptal APs. The aim of this study was to identify ECG features of manifest APs located in this complex paraseptal space. METHODS AND RESULTS ECG characteristics of all patients who underwent radiofrequency ablation of an AP during a 3 year period were analyzed. Of the 239 patients with one or more APs, 30 patients had a paraseptal AP with preexcitation. Compared to APs within the coronary sinus (CS) or the middle cardiac vein (MCV) the right sided paraseptal APs significantly more often showed an isoelectric delta wave in lead II and/or a negative delta wave in aVR. The left sided paraseptal APs presented a negative delta wave in II significantly more often compared to the right sided APs. CONCLUSIONS According to the site of radiofrequency ablation, paraseptal APs are classified into 4 subgroups: paraseptal right, paraseptal left, inside the CS or inside the MCV. Subtle differences in preexcitation patterns of the delta wave as well as of the QRS complex exist. However, the definitive localization of APs remains reserved to the periinterventional intracardiac electrogram analysis.
Resumo:
INTRODUCTION Catheter ablation for idiopathic ventricular arrhythmia is well established but epicardial origin, proximity to coronary arteries, and limited accessibility may complicate ablation from the venous system in particular from the great cardiac vein (GCV). METHODS Between April 2009 and October 2010 14 patients (56 ± 15 years; 9 male) out of a total group of 117 patients with idiopathic outflow tract tachycardias were included undergoing ablation for idiopathic VT or premature ventricular contractions (PVC) originating from GCV. All patients in whom the PVC arose from the GCV were subject to the study. In these patients angiography of the left coronary system was performed with the ablation catheter at the site of earliest activation. RESULTS Successful ablation was performed in 6/14 (43%) and long-term success was achieved in 5/14 (36%) patients. In 4/14 patients (28.6%) ablation was not performed. In another 4 patients (26.7%), ablation did not abolish the PVC/VT. In the majority, the anatomical proximity to the left coronary system prohibited effective RF application. In 3 patients RF application resulted in a coronary spasm with complete regression as revealed in repeat coronary angiography. CONCLUSION A relevant proportion idiopathic VT/PVC can safely be ablated from the GCV without significant permanent coronary artery stenosis after RF application. Our data furthermore demonstrate that damage to the coronary artery system is likely to be transient.
Resumo:
OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
Resumo:
Oral contraceptives containing synthetic oestrogens have been used successfully as birth control for > 40 years and are currently prescribed to > 100 million women worldwide. Several new progestins have been introduced and the third generation of progestins has now been available for two decades. Oral contraceptives are prescribed over a prolonged period of time and therefore substantially impact on hormonal, metabolic and plasmatic functions. Oral contraceptives increase the risk for venous thrombosis and pulmonary embolism, particularly if associated with confounding factors, such as genetic predisposition, smoking, hypertension or obesity. The risk of developing coronary artery disease is also increased in users with cardiovascular risk factors. This article discusses mechanistic and clinical issues and reviews the need for novel approaches targeting the considerable side effects in order to reduce cardiovascular morbidity in women using oral contraceptives.
Resumo:
BACKGROUND We aimed to describe the effects of ticagrelor versus clopidogrel on stent thrombosis in the Platelet Inhibition and Patient Outcomes (PLATO) trial. METHODS AND RESULTS Of 18 624 patients hospitalized for acute coronary syndromes, 11 289 (61%) had at least 1 intracoronary stent. Ticagrelor reduced stent thrombosis compared with clopidogrel across all definitions: definite, 1.37% (n=71) versus 1.93% (n=105; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.50-0.90; P=0.0091); definite or probable, 2.21% (n=118) versus 2.87% (n=157; HR, 0.75; 95% CI, 0.59-0.95; P=0.017); and definite, probable, and possible, 2.94% (n=154) versus 3.77 (n=201; HR, 0.77; 95% CI, 0.62-0.95). The reduction in definite stent thrombosis was consistent regardless of acute coronary syndrome type, presence of diabetes mellitus, stent type (drug-eluting or bare metal stent), CYP2C19 genetic status, loading dose of aspirin, dose of clopidogrel before randomization, and use of glycoprotein IIb/IIIa inhibitors at randomization. The reduction in stent thrombosis with ticagrelor was numerically greater for late (>30 days; HR, 0.48; 95% CI, 0.24-0.96) and subacute (4 hours-30 days; HR, 0.60; 95% CI, 0.39-0.93) compared with acute (<24 hours; HR, 0.94; 95% CI, 0.43-2.05) stent thrombosis or for patients compliant to therapy (ie, taking blinded study treatment ≥80% of the time) compared with less compliant patients. Randomization to ticagrelor was a strong independent inverse predictor of definite stent thrombosis (HR, 0.65; 95% CI, 0.48-0.88). CONCLUSION Ticagrelor compared with clopidogrel reduces the incidence of stent thrombosis in patients with acute coronary syndromes, with consistent benefit across a broad range of patient, stent, and treatment characteristics.
Resumo:
BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.
Resumo:
BACKGROUND Although well-established for suspected lower limb deep venous thrombosis, an algorithm combining a clinical decision score, d-dimer testing, and ultrasonography has not been evaluated for suspected upper extremity deep venous thrombosis (UEDVT). OBJECTIVE To assess the safety and feasibility of a new diagnostic algorithm in patients with clinically suspected UEDVT. DESIGN Diagnostic management study. (ClinicalTrials.gov: NCT01324037) SETTING: 16 hospitals in Europe and the United States. PATIENTS 406 inpatients and outpatients with suspected UEDVT. MEASUREMENTS The algorithm consisted of the sequential application of a clinical decision score, d-dimer testing, and ultrasonography. Patients were first categorized as likely or unlikely to have UEDVT; in those with an unlikely score and normal d-dimer levels, UEDVT was excluded. All other patients had (repeated) compression ultrasonography. The primary outcome was the 3-month incidence of symptomatic UEDVT and pulmonary embolism in patients with a normal diagnostic work-up. RESULTS The algorithm was feasible and completed in 390 of the 406 patients (96%). In 87 patients (21%), an unlikely score combined with normal d-dimer levels excluded UEDVT. Superficial venous thrombosis and UEDVT were diagnosed in 54 (13%) and 103 (25%) patients, respectively. All 249 patients with a normal diagnostic work-up, including those with protocol violations (n = 16), were followed for 3 months. One patient developed UEDVT during follow-up, for an overall failure rate of 0.4% (95% CI, 0.0% to 2.2%). LIMITATIONS This study was not powered to show the safety of the substrategies. d-Dimer testing was done locally. CONCLUSION The combination of a clinical decision score, d-dimer testing, and ultrasonography can safely and effectively exclude UEDVT. If confirmed by other studies, this algorithm has potential as a standard approach to suspected UEDVT. PRIMARY FUNDING SOURCE None.
Resumo:
BACKGROUND AND AIMS Liver stiffness is increasingly used in the non-invasive evaluation of chronic liver diseases. Liver stiffness correlates with hepatic venous pressure gradient (HVPG) in patients with cirrhosis and holds prognostic value in this population. Hence, accuracy in its measurement is needed. Several factors independent of fibrosis influence liver stiffness, but there is insufficient information on whether meal ingestion modifies liver stiffness in cirrhosis. We investigated the changes in liver stiffness occurring after the ingestion of a liquid standard test meal in this population. METHODS In 19 patients with cirrhosis and esophageal varices (9 alcoholic, 9 HCV-related, 1 NASH; Child score 6.9±1.8), liver stiffness (transient elastography), portal blood flow (PBF) and hepatic artery blood flow (HABF) (Doppler-Ultrasound) were measured before and 30 minutes after receiving a standard mixed liquid meal. In 10 the HVPG changes were also measured. RESULTS Post-prandial hyperemia was accompanied by a marked increase in liver stiffness (+27±33%; p<0.0001). Changes in liver stiffness did not correlate with PBF changes, but directly correlated with HABF changes (r = 0.658; p = 0.002). After the meal, those patients showing a decrease in HABF (n = 13) had a less marked increase of liver stiffness as compared to patients in whom HABF increased (n = 6; +12±21% vs. +62±29%,p<0.0001). As expected, post-prandial hyperemia was associated with an increase in HVPG (n = 10; +26±13%, p = 0.003), but changes in liver stiffness did not correlate with HVPG changes. CONCLUSIONS Liver stiffness increases markedly after a liquid test meal in patients with cirrhosis, suggesting that its measurement should be performed in standardized fasting conditions. The hepatic artery buffer response appears an important factor modulating postprandial changes of liver stiffness. The post-prandial increase in HVPG cannot be predicted by changes in liver stiffness.
Resumo:
This manuscript deals with the adaptation of quartz-microfabrics to changing physical deformation conditions, and discusses their preservation potential during subsequent retrograde deformation. Using microstructural analysis, a sequence of recrystallization processes in quartz, ranging from Grain-Boundary Migration Recrystallization (GBM) over Subgrain-Rotation Recrystallization (SGR) to Bulging Nucleation (BLG) is detected for the Simplon fault zone (SFZ) from the low strain rim towards the internal high strain part of the large-scale shear zone. Based on: (i) the retrograde cooling path; (ii) estimates of deformation temperatures; and (iii) spatial variation of dynamic recrystallization processes and different microstructural characteristics, continuous strain localization with decreasing temperature is inferred. In contrast to the recrystallization microstructures, crystallographic preferred orientations (CPO) have a longer memory. CPO patterns indicative of prism and rhomb glide systems in mylonitic quartz veins, overprinted at low temperatures (�400 �C), suggest inheritance of a high-temperature deformation. In this way, microstructural, textural and geochemical analyses provide information for several million years of the deformation history. The reasons for such incomplete resetting of the rock texture is that strain localization is caused by change in effective viscosity contrasts related to temporal large- and small-scale temperature changes during the evolution of such a long-lived shear zone. The spatially resolved, quantitative investigation of quartz microfabrics and associated recrystallization processes therefore provide great potential for an improved understanding of the geodynamics of large-scale shear zones.
Resumo:
OBJECTIVE Everolimus drug-eluting stents (EES) are superior to early-generation drug-eluting stents (DES), releasing sirolimus (SES) or paclitaxel (PES) in preventing stent thrombosis (ST). Since an impaired LVEF seems to increase the risk of ST, we aimed to investigate the difference in outcome of patients with varying LVEF using EES versus early-generation DES. METHODS In a prospective cohort study, we compared the risk of ST in patients in three LVEF subgroups: normal (LVEF >50%), mildly impaired (LVEF >40% and ≤50%) and moderate-severely impaired (LVEF ≤40%). Within these various LVEF groups, we compared EES with SES and PES after adjustment for baseline differences. RESULTS We assessed a cohort of 5363 patients, with follow-up of up to 4 years and available LVEF. Overall definite ST occurred in 123 (2.3%) patients. ST rates were higher in the LVEF moderate-severely impaired group compared with the normal LVEF group (2.8% vs 2.1%; HR 1.82; CI 1.10 to 3.00). Especially early ST (EST) was more frequent in the moderate-severely impaired LVEF group (HR 2.20; CI 1.06 to 4.53). Overall rates of definite ST were lower in patients using EES compared with patients using SES or PES in all LVEF groups. Interaction terms were not statistically significant. ST rates were higher in the moderate-severely impaired LVEF group compared with the normal LVEF group when using SES or PES, but not significantly different when using EES. CONCLUSIONS EES was associated with a lower risk of definite ST compared with early-generation DES. This lower risk was independent of LVEF, even though ST rates were higher in patients with a moderate-severely impaired LVEF. TRIAL REGISTRATION NO MEC-2013-262.