166 resultados para ORTHOPAEDIC FIXATION DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To compare clinical outcome of Amplatzer PFO (APFO) to Cardia PFO (CPFO) occluder. Percutaneous patent foramen ovale (PFO) closure prevents stroke recurrence in stroke due to paradoxical embolism. Methods and results: The primary endpoint was a composite of stroke, TIA, or peripheral embolism at follow-up. The secondary endpoint was residual shunt. Outcome was compared among 934 (APFO: 712; CPFO: 222) patients, and in 297 propensity score-matched patients. The primary endpoint occurred in 29 patients (0.71/100 patient-years): four (2%) with the CPFO (0.31/100 patient-years), and 25 (4%) with the APFO (0.89/100 patient-years) (p=0.20). Residual shunt at six months was more frequent with the CPFO (31% versus 9%, p<0.001). No differences in residual shunts were seen at the last available echocardiographic follow-up (9±18 months): APFO 11%, CPFO 14%, p=0.22. Conclusions: This study suggests that PFO closure with APFO or CPFO is equally effective for the prevention of recurrent events. Residual shunt was more frequent at six months with CPFO, but was similar to APFO at later follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upconverter materials and upconverter solar devices were recently investigated with broad-band excitation revealing the great potential of upconversion to enhance the efficiency of solar cell at comparatively low solar concentration factors. In this work first attempts are made to simulate the behavior of the upconverter β-NaYF4 doped with Er3+ under broad-band excitation. An existing model was adapted to account for the lower absorption of broader excitation spectra. While the same trends as observed for the experiments were found in the simulation, the absolute values are fairly different. This makes an upconversion model that specifically considers the line shape function of the ground state absorption indispensable to achieve accurate simulations of upconverter materials and upconverter solar cell devices with broadband excitations, such as the solar radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to evaluate the quality of histo- and cytomorphological features of PAXgene-fixed specimens and their suitability for histomorphological classification in comparison to standard formalin fixation. Fifteen colon cancer tissues were collected, divided into two mirrored samples and either formalin fixed (FFPE) or PAXgene fixed (PFPE) before paraffin embedding. HE- and PAS-stained sections were scanned and evaluated in a blinded, randomised ring trial by 20 pathologists from Europe and the USA using virtual microscopy. The pathologists evaluated histological grading, histological subtype, presence of adenoma, presence of lymphovascular invasion, quality of histomorphology and quality of nuclear features. Statistical analysis revealed that the reproducibility with regard to grading between both fixation methods was rather satisfactory (weighted kappa statistic (k w) = 0.73 (95 % confidence interval (CI), 0.41-0.94)), with a higher agreement between the reference evaluation and the PFPE samples (k w = 0.86 (95 % CI, 0.67-1.00)). Independent from preservation method, inter-observer reproducibility was not completely satisfactory (k w = 0.60). Histomorphological quality parameters were scored equal or better for PFPE than for FFPE samples. For example, overall quality and nuclear features, especially the detection of mitosis, were judged significantly better for PFPE cases. By contrast, significant retraction artefacts were observed more frequently in PFPE samples. In conclusion, our findings suggest that the PAXgene Tissue System leads to excellent preservation of histomorphology and nuclear features of colon cancer tissue and allows routine morphological diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Despite its limitations, citation analysis remains one of the best currently available tools for quantifying the impact of articles. Bibliometric studies list the "best-sellers" in a single location, and they have been published frequently in many fields during recent years. The purpose of the present study was to report the qualities and characteristics of citation classics in orthopaedic knee research. METHODS: The database of the Institute for Scientific Information (ISI) was utilized for identification of articles published from 1945 to March 2014. All knee articles that had been published in sixty-five orthopaedic and twenty-nine rheumatology journals and that had been cited at least 200 times were identified. The top 100 were selected for further analysis of authorship, source journal, number of citations, citation rate (both since publication and in 2013), geographic origin, article type, and level of evidence. RESULTS: The publication dates of the 100 most-cited articles ranged from 1948 to 2007, with the greatest number of articles published in the 1980s. Citations per article ranged from 2640 to 287. All articles were published in eleven of the ninety-four journals. The leading countries of origin were the U.S. followed by the U.K. and Sweden. The two main focus areas were sports traumatology and degenerative disease. The number of citations per article was also greatest for articles published in the 1980s. Basic research articles were cited more quickly, but not more often, than clinical articles. Most articles represented Level-IV evidence, followed by Levels II, III, and I. CONCLUSIONS: This bibliometric study is likely to include a list of intellectual milestones in orthopaedic knee research. It is apparent that a high level of evidence is not mandatory for an article to gain a large number of citations. Bibliometric reports provide a reflection of the quality of cited research published in a specific field and should therefore provoke thinking within the scientific community.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. To the best of our knowledge, this is the first study that tests whether the use of mobile devices affects survey characteristics and stated preferences in a web-based choice experiment. The web survey was carried out in Germany with 3,400 respondents, of which 12 per cent used a mobile device (i.e. tablet or smartphone), and comprised a stated choice experiment on externalities of renewable energy production using wind, solar and biomass. Our main finding is that survey characteristics such as interview length and acquiescence tendency are affected by the device used. In contrast to what might be expected, we find that, compared with respondents using desktop computers and laptops, mobile device users spent more time to answer the survey and are less likely to be prone to acquiescence bias. In the choice experiment, mobile device users tended to be more consistent in their stated choices, and there are differences in willingness to pay between both subsamples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined for resistance towards traction force using an analogue spring scale. Results. Most systems showed a high level of movement already under small traction force. Retractable systems with round hooks such as the Bard DuaLok , the Fil d'Ariane, and the RPLN Breast Localization Device withstood less traction force than the other systems. However, the Bard DuaLok system was very resistant towards a small traction force of 50 g when compared to the other systems. The Ultrawire Breast Localization Device withstood the most traction force in softer tissue and Kopans Breast Lesion Localization Needle withstood the most force in harder tissue. Conclusion. The Ultrawire Breast Localization Device and Kopans Breast Lesion Localization Needle withstood the most traction force. In general retractable systems withstand less traction force than nonretractable systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many end-stage heart failure patients are not eligible to undergo heart transplantation due to organ shortage, and even those under consideration for transplantation might suffer long waiting periods. A better understanding of the hemodynamic impact of left ventricular assist devices (LVAD) on the cardiovascular system is therefore of great interest. Computational fluid dynamics (CFD) simulations give the opportunity to study the hemodynamics in this patient population using clinical imaging data such as computed tomographic angiography. This article reviews a recent study series involving patients with pulsatile and constant-flow LVAD devices in which CFD simulations were used to qualitatively and quantitatively assess blood flow dynamics in the thoracic aorta, demonstrating its potential to enhance the information available from medical imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.