154 resultados para Nerve block


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A general introduction to the state of the art in modeling metal organic materials using transferable atomic multipoles is provided. The method is based on the building block partitioning of the electron density, which is illustrated with some examples of potential applications and with detailed discussions of the advantages and pitfalls. The interactions taking place between building blocks are summarized and are used to discuss the properties that can be calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The sedimentation sign (SedSign) has been shown to discriminate well between selected patients with and without lumbar spinal stenosis (LSS). The purpose of this study was to compare the pressure values associated with LSS versus non-LSS and discuss whether a positive SedSign may be related to increased epidural pressure at the level of the stenosis. Methods We measured the intraoperative epidural pressure in five patients without LSS and a negative SedSign, and in five patients with LSS and a positive SedSign using a Codman TM catheter in prone position under radioscopy. Results Patients with a negative SedSign had a median epidural pressure of 9 mmHg independent of the measurement location. Breath and pulse-synchronous waves accounted for 1–3 mmHg. In patients with monosegmental LSS and a positive SedSign, the epidural pressure above and below the stenosis was similar (median 8–9 mmHg). At the level of the stenosis the median epidural pressure was 22 mmHg. A breath and pulse-synchronous wave was present cranial to the stenosis, but absent below. These findings were independent of the cross-sectional area of the spinal canal at the level of the stenosis. Conclusions Patients with LSS have an increased epidural pressure at the level of the stenosis and altered pressure wave characteristics below. We argue that the absence of sedimentation of lumbar nerve roots to the dorsal part of the dural sac in supine position may be due to tethering of affected nerve roots at the level of the stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuropathic pain caused by peripheral nerve injury is a debilitating neurological condition of high clinical relevance. On the cellular level, the elevated pain sensitivity is induced by plasticity of neuronal function along the pain pathway. Changes in cortical areas involved in pain processing contribute to the development of neuropathic pain. Yet, it remains elusive which plasticity mechanisms occur in cortical circuits. We investigated the properties of neural networks in the anterior cingulate cortex (ACC), a brain region mediating affective responses to noxious stimuli. We performed multiple whole-cell recordings from neurons in layer 5 (L5) of the ACC of adult mice after chronic constriction injury of the sciatic nerve of the left hindpaw and observed a striking loss of connections between excitatory and inhibitory neurons in both directions. In contrast, no significant changes in synaptic efficacy in the remaining connected pairs were found. These changes were reflected on the network level by a decrease in the mEPSC and mIPSC frequency. Additionally, nerve injury resulted in a potentiation of the intrinsic excitability of pyramidal neurons, whereas the cellular properties of interneurons were unchanged. Our set of experimental parameters allowed constructing a neuronal network model of L5 in the ACC, revealing that the modification of inhibitory connectivity had the most profound effect on increased network activity. Thus, our combined experimental and modeling approach suggests that cortical disinhibition is a fundamental pathological modification associated with peripheral nerve damage. These changes at the cortical network level might therefore contribute to the neuropathic pain condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATE OF THE ART The proximal median nerve compression syndrome includes the pronator teres and the Kiloh-Nevin syndrome. This article presents a new surgical technique of endoscopic assisted median nerve decompression. MATERIAL AND SURGICAL TECHNIQUE Endoscopic scissor decompression of the median nerve is always performed under plexus anaesthesia. It includes 6 key steps documented in this article. We review the indications and limitations of the surgical technique. RESULTS Since 2011, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We also review the limitations of the technique and its potential for future development. CONCLUSION Although clinical results after endoscopic assisted decompression of the median nerve appear excellent they still need to be compared with conventional techniques. Clinical studies are likely to develop primarily due to the mini-invasive nature of this new surgical technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 13-year-old male neutered domestic shorthaired cat had repeated syncopal episodes over a 6 month period, which had variable duration and continued to increase in frequency. Intermittent ventricular asystole, due to complete heart block, and hyperthyroidism were documented. As the syncopal episodes did not respond to a 4-week medical treatment and symptoms became severe, a transvenous ventricular demand pacemaker system (VVIM) was implanted via the external jugular vein. The unipolar lead was tunneled subcutaneously and connected with the generator in a preformed ventral abdominal muscle pocket. During follow up of 18-months there were no recurrences of the syncopal episodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To develop and evaluate a method for ultrasound-guidance in performing the proximal paravertebral block for flank anaesthesia in cattle through a cadaveric study, followed by clinical application. STUDY DESIGN prospective experimental cadaveric study and clinical series. ANIMALS Previously frozen lumbar sections of cows without known spinal abnormalities were used. The clinical case group comprised of ten animals for which a right flank laparotomy was indicated. METHODS Twenty cow cadavers were used to perform ultrasound-guided bilateral injections of 1.0 mL dye (1.0 mL 1% Toluidine Blue in 1% Borax) at the intervertebral foramen at the level of T13, L1 and L2 spinal nerves. Distance and depth of injection, staining of the dorsal and ventral nerve branches, and deviation from the target were evaluated. The investigator's confidence as to visualisation and expected success at staining the nerve was assessed. Ten clinical cases received the ultrasound-guided proximal paravertebral anaesthesia. Analgesic success was evaluated using a 4-grade scoring system at 10 minutes after the injection and during surgery, respectively. Categorical variables were described using frequencies and proportions. RESULTS Both dorsal and ventral branches of the spinal nerves T13, L1 or L2 were at least partially stained in 41% of injections, while in 77% of injections one of the branches was stained. Five out of ten clinical cases had a satisfactory anaesthesia. There was no significant association between confidence at injection and either staining or analgesic success. CONCLUSION Results from the cadaveric and clinical study suggest no significant improvement using ultrasound guidance to perform proximal paravertebral block in cows compared to our previous clinical experience and to references in the literature using the blind method. CLINICAL RELEVANCE Further research should be conducted to improve the ultrasound-guided technique described in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 7-year-old male intact Rottweiler was presented with a 1-week history of lethargy, anorexia, vomiting and multiple syncopal events. The results of the clinical examination and electrocardiography were consistent with a third degree atrioventricular block and an intermittent accelerated idioventricular rhythm. Haematology, serum biochemistry, serology for Borrelia burgdorferi, blood culture, total T4, thoracic radiography and echocardiography did not reveal the cause of the arrhythmia. Response to medical treatment with isoproterenol was poor. Pacemaker placement was declined by the owners and the dog was euthanized at their request. Histopathological examination of the heart revealed a chemodectoma at the base of the heart. There was no neoplastic infiltration of the conduction tissue. Potential mechanisms explaining the association of the arrhythmias and the tumour, such as vagal stimulation and neuroendocrine factors are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The first ophthalmologic complication in conjunction with a dental anesthesia was reported in 1936. The objective of the present study was a detailed analysis of case reports about that topic. MATERIAL AND METHODS After conducting a literature search in PubMed this study analyzed 108 ophthalmologic complications following intraoral local anesthesia in 65 case reports with respect to patient-, anesthesia-, and complication- related factors. RESULTS The mean age of the patients was 33.8 years and females predominated (72.3%). The most commonly reported complication was diplopia (39.8%), mostly resulting from paralysis of the lateral rectus muscle. Other relatively frequent complications included ptosis (16.7%), mydriasis (14.8%) and amaurosis (13%). Ophthalmologic complications were mainly associated with block anesthesia of the inferior alveolar nerve (45.8%) or the posterior superior alveolar nerve (40.3%). Typically, the ophthalmologic complications in conjunction with intraoral local anesthesia had an immediate to short onset, and disappeared as the anesthesia subsided. DISCUSSION AND CONCLUSION The increased number of ophthalmologic complications after intraoral local anesthesia in females may suggest a gender effect. Double vision (diplopia) is the most frequently described complication, which is usually completely reversible like the other reported ophthalmologic complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(ethylene oxide) (PEO) has long been used as an additive in toothpaste, partly because it reduces biofilm formation on teeth. It does not, however, reduce the formation of dental calculus or support the remineralization of dental enamel or dentine. The present article describes the synthesis of new block copolymers on the basis of PEO and poly(3-sulfopropyl methacrylate) blocks using atom transfer radical polymerization. The polymers have very large molecular weights (over 10(6) g/mol) and are highly water-soluble. They delay the precipitation of calcium phosphate from aqueous solution but, upon precipitation, lead to relatively monodisperse hydroxyapatite (HAP) spheres. Moreover, the polymers inhibit the bacterial colonization of human enamel by Streptococcus gordonii, a pioneer bacterium in oral biofilm formation, in vitro. The formation of well-defined HAP spheres suggests that a polymer-induced liquid precursor phase could be involved in the precipitation process. Moreover, the inhibition of bacterial adhesion suggests that the polymers could be utilized in caries prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Altered gap junctional coupling potentiates slow conduction and arrhythmias. To better understand how heterogeneous connexin expression affects conduction at the cellular scale, we investigated conduction in tissue consisting of two cardiomyocyte populations expressing different connexin levels. Conduction was mapped using microelectrode arrays in cultured strands of foetal murine ventricular myocytes with prede fi ned contents of connexin 43 knockout (Cx43KO) cells. Corresponding computer simulations were run in randomly generated two-dimensional tissues mimicking the cellular architecture of the strands. In the cultures, the relationship between conduction velocity (CV) and Cx43KO cell content was nonlinear. CV fi rst decreased signi fi cantly when Cx43KO content was increased from 0 to 50%. When the Cx43KO content was ≥ 60%, CV became comparabletothatin100%Cx43KOstrands.Co-culturingCx43KOandwild-typecellsalsoresultedinsigni fi cantly more heterogeneous conduction patterns and in frequent conduction blocks. The simulations replicated this behaviour of conduction. For Cx43KO contents of 10 – 50%, conduction was slowed due to wavefront meandering between Cx43KO cells. For Cx43KO contents ≥ 60%, clusters of remaining wild-type cells acted as electrical loads thatimpairedconduction.ForCx43KOcontentsof40 – 60%,conductionexhibitedfractal characteristics,wasprone to block, and was more sensitive to changes in ion currents compared to homogeneous tissue. In conclusion, conduction velocity and stability behave in a nonline ar manner when cardiomyocytes expressing different connexin amounts are combined. This behaviour results from heterogeneous current-to-load relationships at the cellular level. Such behaviour is likely to be arrhythmogenic in various clinical contexts in which gap junctional coupling is heterogeneous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND It has been suggested that sleep apnea syndrome may play a role in normal-tension glaucoma contributing to optic nerve damage. The purpose of this study was to evaluate if optic nerve and visual field parameters in individuals with sleep apnea syndrome differ from those in controls. PATIENTS AND METHODS From the records of the sleep laboratory at the University Hospital in Bern, Switzerland, we recruited consecutive patients with severe sleep apnea syndrome proven by polysomnography, apnea-hypopnea index >20, as well as no sleep apnea controls with apnea-hypopnea index <10. Participants had to be unknown to the ophtalmology department and had to have no recent eye examination in the medical history. All participants underwent a comprehensive eye examination, scanning laser polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, California), scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II, HRT II), and automated perimetry (Octopus 101 Programm G2, Haag-Streit Diagnostics, Koeniz, Switzerland). Mean values of the parameters of the two groups were compared by t-test. RESULTS The sleep apnea group consisted of 69 eyes of 35 patients; age 52.7 ± 9.7 years, apnea-hypopnea index 46.1 ± 24.8. As controls served 38 eyes of 19 patients; age 45.8 ± 11.2 years, apnea-hypopnea index 4.8 ± 1.9. A difference was found in mean intraocular pressure, although in a fully overlapping range, sleep apnea group: 15.2 ± 3.1, range 8-22 mmHg, controls: 13.6 ± 2.3, range 9-18 mmHg; p<0.01. None of the extended visual field, optic nerve head (HRT) and retinal nerve fiber layer (GDx VCC) parameters showed a significant difference between the groups. CONCLUSION Visual field, optic nerve head, and retinal nerve fiber layer parameters in patients with sleep apnea did not differ from those in the control group. Our results do not support a pathogenic relationship between sleep apnea syndrome and glaucoma.