217 resultados para NONMATCHING IMPLANT
Resumo:
PURPOSE The purpose of the present study was to evaluate the thickness and anatomic characteristics of the sinus membrane using cone beam computed tomography (CBCT) in patients evaluated for implant surgery in the posterior maxilla. MATERIALS AND METHODS The study included 131 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 138 CBCT images was obtained using fields of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted sagittal CBCT slices were analyzed with regard to the thickness and characteristics of the sinus membrane at single-tooth gaps in the posterior maxilla. Factors that might influence the dimensions of the sinus membrane, such as age, sex, endodontic status, and the season, were analyzed. RESULTS The mean thickness of the maxillary sinus mucosa varied between 2.1 and 2.69 mm in the three locations analyzed. Fewer than half of the evaluated sinuses exhibited a healthy mucosa (49 of 138, or 35.51%). Most of the pathologic findings were flat, shallow thickenings (63 of 138, or 45.65%). Sex did not influence the thickness of the sinus membrane at the root tips of the premolars or at single-tooth gaps, but there was a statistically significant correlation in the region of the maxillary molars. No other evaluated factors had a statistically significant effect on the dimensions of the antral mucosa. CONCLUSIONS In the present study, sex was the only factor influencing the dimension of the sinus membrane, whereas patient age, season, and the endodontic status of neighboring teeth had no significant effect on the thickness of the antral mucosa. Future studies should address which types of mucosal thickening require interdisciplinary therapy.
Resumo:
The removal of nonretrievable implant components represents a challenge in implant dentistry. The mechanical approach involves the risk of damaging the implant connection or the bone-to-implant interface. This case report describes a cryo-mechanical approach for the safe removal of a nonretrievable implant component. A patient had an implant surgically placed in a private practice. When the patient returned to the restorative dentist to make a definitive impression, the healing abutment could not be loosened. The patient was referred to the Division of Fixed Prosthodontics (University of Bern, Switzerland), where the stripped screw hole was enlarged with a special drill from a service kit of the implant provider. Although an extraction bolt was screwed into the opening and the torque ratchet was activated, the healing abutment would not loosen. A novel approach was attempted whereby the healing abutment was cooled with dry ice (CO2). The cooling effect seemingly caused shrinkage of the healing abutment and a reduction of the connection forces between the implant and the nonretrievable component. The approach of creating an access hole for the application of reverse torque via the extraction bolt in combination with the thermal effect led to the successful removal of the blocked component. Neither the implant connection nor the bone-to-implant interface was damaged. The combined cryo-mechanical procedure allowed the implant to be successfully restored.
Resumo:
Purpose: The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Materials and Methods: Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. Results: After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Conclusions: Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.
Resumo:
In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.
Resumo:
BACKGROUND Early implant placement with simultaneous contour augmentation is documented with short- and medium-term studies. The long-term stability of contour augmentation is uncertain. METHODS In this prospective, cross-sectional study, 41 patients with an implant-borne single crown were examined twice, in 2006 and 2010. Clinical, radiologic, and esthetic parameters were assessed at both examinations. In addition, a cone beam computed tomographic (CBCT) image was obtained during the second examination to assess the dimensions of the facial bone wall. RESULTS All 41 implants demonstrated ankylotic stability without signs of peri-implant infection at both examinations. The clinical parameters remained stable over time. Satisfactory esthetic outcomes were noted, as assessed by the pink and white esthetic score (PES/WES) indices. Overall, the PES scores were slightly higher than the WES scores. None of the implants developed mucosal recession over time, as confirmed by values of the distance between implant shoulder and mucosal margin and cast measurements. The periapical radiographs yielded stable peri-implant bone levels, with a mean distance between implant shoulder and first visible bone-implant contact value of 2.18 mm. The CBCT analysis demonstrated a mean thickness of the facial bone wall ≈2.2 mm. In two implants (4.9%) no facial bone wall was detectable radiographically. CONCLUSIONS This prospective cross-sectional study demonstrates stable peri-implant hard and soft tissues for all 41 implants examined and satisfactory esthetic outcomes overall. The follow-up of 5 to 9 years confirmed again that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration was able to establish and maintain a facial bone wall in 95% of patients.
Resumo:
The purpose of this study was to analyze the width and height of edentulous sites in the posterior maxilla using cone beam computed tomography (CBCT) images from patients referred for implant therapy. A total of 122 CBCT scans were included in the analysis, resulting in a sample size of 252 edentulous sites. The orofacial crest width was measured in coronal slices, perpendicular to the alveolar ridge. The bone height was analyzed in the respective sagittal slices. Additionally, the following secondary outcome parameters were evaluated: the morphology of the sinus floor, the presence of septa in the maxillary sinus, and the thickness of the sinus membrane. The mean crest width for all analyzed sites was 8.28 mm, and the mean bone height was 7.22 mm. The percentage of patients with a crest width of less than 6 mm was 27% in premolar sites and 7.8% in molar sites. The bone height decreased from premolar to molar areas, with a high percentage of first and second molar sites exhibiting a bone height of less than 5 mm (54.12% and 44.64%, respectively). Regarding the morphology of the sinus floor, 53% of the edentulous sites exhibited a flat configuration. A septum was present in 67 edentulous sites (26.59%). Analysis of the sinus membrane revealed 88 sites (34.9%) with increased mucosal thickness (> 2 mm). For the crest width, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. For the crest width and mean bone height, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. The study confirmed that a high percentage of edentulous sites in the posterior maxilla do require sinus floor elevation to allow the placement of dental implants. Therefore, a detailed three-dimensional radiograph using CBCT is indicated in most patients for proper treatment planning.
Resumo:
BACKGROUND Deproteinized bovine bone mineral (DBBM) is one of the best-documented bone substitute materials for sinus floor elevation (SFE). PURPOSE DBBM is available in two particle sizes. Large particles are believed to facilitate improved neoangiogenesis compared with small ones. However, their impact on the rate of new bone formation, osteoconduction, and DBBM degradation has never been reported. In addition, the implant stability quotient (ISQ) has never been correlated to bone-to-implant contact (BIC) after SFE with simultaneous implant placement. MATERIALS AND METHODS Bilateral SFE with simultaneous implant placement was performed in 10 Göttingen minipigs. The two sides were randomized to receive large or small particle size DBBM. Two groups of 5 minipigs healed for 6 and 12 weeks, respectively. ISQ was recorded immediately after implant placement and at sacrifice. Qualitative histological differences were described and bone formation, DBBM degradation, BIC and bone-to-DBBM contact (osteoconduction) were quantified histomorphometrically. RESULTS DBBM particle size had no qualitative or quantitative impact on the amount of newly formed bone, DBBM degradation, or BIC for either of the healing periods (p > 0.05). Small-size DBBM showed higher osteoconduction after 6 weeks than large-size DBBM (p < 0.001). After 12 weeks this difference was compensated. There was no significant correlation between BIC and ISQ. CONCLUSION Small and large particle sizes were equally predictable when DBBM was used for SFE with simultaneous implant placement.
Resumo:
OBJECTIVE Recent review articles have shown that open debridement is more effective in the treatment of peri-implantitis than closed therapy. However, surgery may result in marginal recession and compromise esthetics. The purpose of this study was to assess the efficacy of nonsurgical antimicrobial photodynamic therapy (aPDT) in moderate vs severe defects. METHOD AND MATERIALS The study encompassed 16 patients with a total of 18 ailing implants. Ten of these implants showed moderate bone loss (< 5 mm; Group 1) and eight implants severe defects (5 through 8 mm; Group 2). All implants received aPDT without surgical intervention. At baseline and 2 weeks, 3 months, and 6 months after therapy, peri-implant health was assessed including sulcus bleeding index (SBI), probing depth (PD), distance from implant shoulder to marginal mucosa (DIM), and clinical attachment level (CAL). Radiographic evaluation of distance from implant to bone (DIB) allowed comparison of peri-implant hard tissues after 6 months. RESULTS Baseline values for SBI were comparable in both groups. Three months after therapy, in both groups, SBI and CAL decreased significantly. In contrast, after 6 months, CAL and DIB increased significantly in Group 2, not in Group 1. However, DIM-values were not statistically different 6 months after therapy in both groups. CONCLUSION Within the limits of this 6-month study, nonsurgical aPDT could stop bone resorption in moderate peri-implant defects but not in severe defects. However, marginal tissue recession was not significantly different in both groups at the end of the study. Therefore, especially in esthetically important sites, surgical treatment of severe peri-implantitis defects seems to remain mandatory.
Resumo:
OBJECTIVES Dental phobia is a psychological disease and a possible contraindication for implant therapy. The study aimed to show that implant therapy in dental-phobic patients (DP, test group) after adequate psychological and dental pretreatment (PDPT) is successfully possible and results in a similar implant prognosis as in nonfearful patients (NF, control group). METHOD AND MATERIALS 15 DP with PDPT and 15 NF were treated with dental implants and were re-evaluated 2 to 4 years after denture-mounting regarding: alteration of dental anxiety (Hierarchical Anxiety Questionnaire [HAQ], Visual Analog Scale [VAS]), patient satisfaction and compliance, implant success, and peri-implant health. Statistical tests of non-inferiority DP versus NF were performed with Hodges-Lehmann estimators and respective one-sided 97.5% confidence intervals of Moses, and pairwise testings with Mann-Whitney test. RESULTS The DP test group rated its anxiety significantly lower at follow- up than at baseline (PHAQ < .001). However, at follow-up, anxiety was still higher in DP than in NF (PHAQ = .046; PVAS < .001). Implant success at follow-up was 100%. Oral health was equally good in DP and NF patients. At follow-up, all patients were satisfied with implant therapy, but compliance was better for NF (100%) than for DP (73% dental checkup; 67% dental hygienist). CONCLUSION Implant therapy can be successfully performed in DP patients with PDPT as phobia is not negatively influenced by the invasive implant therapy. However, motivation for professional maintenance programs remains challenging.
Resumo:
PURPOSE Extended grafting procedures in atrophic ridges are invasive and time-consuming and increase cost and patient morbidity. Therefore, ridge-splitting techniques have been suggested to enlarge alveolar crests. The aim of this cohort study was to report techniques and radiographic outcomes of implants placed simultaneously with a piezoelectric alveolar ridge-splitting technique (RST). Peri-implant bone-level changes (ΔIBL) of implants placed with (study group, SG) or without RST (control group, CG) were compared. MATERIALS AND METHODS Two cohorts (seven patients in each) were matched regarding implant type, position, and number; superstructure type; age; and gender and received 17 implants each. Crestal implant bone level (IBL) was measured at surgery (T0), loading (T1), and 1 year (T2) and 2 years after loading (T3). For all implants, ΔIBL values were determined from radiographs. Differences in ΔIBL between SG and CG were analyzed statistically (Mann-Whitney U test). Bone width was assessed intraoperatively, and vertical bone mapping was performed at T0, T1, and T3. RESULTS After a mean observation period of 27.4 months after surgery, the implant survival rate was 100%. Mean ΔIBL was -1.68 ± 0.90 mm for SG and -1.04 ± 0.78 mm for CG (P = .022). Increased ΔIBL in SG versus CG occurred mainly until T2. Between T2 and T3, ΔIBL was limited (-0.11 ± 1.20 mm for SG and -0.05 ± 0.16 mm for CG; P = .546). Median bone width increased intraoperatively by 4.7 mm. CONCLUSIONS Within the limitations of this study, it can be suggested that RST is a well-functioning one-stage alternative to extended grafting procedures if the ridge shows adequate height. ΔIBL values indicated that implants with RST may fulfill accepted implant success criteria. However, during healing and the first year of loading, increased IBL alterations must be anticipated.
Resumo:
OBJECTIVES To evaluate prosthetic parameters in the edentulous anterior maxilla for decision making between fixed and removable implant prosthesis using virtual planning software. MATERIAL AND METHODS CT- or DVT-scans of 43 patients (mean age 62 ± 8 years) with an edentulous maxilla were analyzed with the NobelGuide software. Implants (≥3.5 mm diameter, ≥10 mm length) were virtually placed in the optimal three-dimensional prosthetic position of all maxillary front teeth. Anatomical and prosthetic landmarks, including the cervical crown point (C-Point), the acrylic flange border (F-Point), and the implant-platform buccal-end (I-Point) were defined in each middle section to determine four measuring parameters: (1) acrylic flange height (FLHeight), (2) mucosal coverage (MucCov), (3) crown-Implant distance (CID) and (4) buccal prosthesis profile (ProsthProfile). Based on these parameters, all patients were assigned to one of three classes: (A) MucCov ≤ 0 mm and ProsthProfile≥45(0) allowing for fixed prosthesis, (B) MucCov = 0-5 mm and/or ProsthProfile = 30(0) -45(0) probably allowing for fixed prosthesis, and (C) MucCov ≥ 5 mm and/or ProsthProfile ≤ 30(0) where removable prosthesis is favorable. Statistical analyses included descriptive methods and non-parametric tests. RESULTS Mean values were for FLHeight 10.0 mm, MucCov 5.6 mm, CID 7.4 mm, and ProsthProfile 39.1(0) . Seventy percent of patients fulfilled class C criteria (removable), 21% class B (probably fixed), and 2% class A (fixed), while in 7% (three patients) bone volume was insufficient for implant planning. CONCLUSIONS The proposed classification and virtual planning procedure simplify the decision-making process regarding type of prosthesis and increase predictability of esthetic treatment outcomes. It was demonstrated that in the majority of cases, the space between the prosthetic crown and implant platform had to be filled with prosthetic materials.
Resumo:
PURPOSE To investigate the adequacy of potential sites for insertion of orthodontic mini-implants (OMIs) in the anterior alveolar region (delimited by the first premolars) through a systematic review of studies that used computed tomography (CT) or cone beam CT (CBCT) to assess anatomical hard tissue parameters, such as bone thickness, available space, and bone density. MATERIALS AND METHODS MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched to identify all relevant papers published between 1980 and September 2011. An extensive search strategy was performed that included the key words "computerized (computed) tomography" and "mini-implants." Information was extracted from the eligible articles for three anatomical areas: maxillary anterior buccal, maxillary anterior palatal, and mandibular anterior buccal. Quantitative data obtained for each anatomical variable under study were evaluated qualitatively with a scoring system. RESULTS Of the 790 articles identified by the search, 8 were eligible to be included in the study. The most favorable area for OMI insertion in the anterior maxilla (buccally and palatally) and mandible is between the canine and the first premolar. The best alternative area in the maxilla (buccally) and the mandible is between the lateral incisor and the canine, while in the maxillary palatal area it is between the central incisors or between the lateral incisor and the canine. CONCLUSIONS Although there is considerable heterogeneity among studies, there is a good level of agreement regarding the optimal site for OMI placement in the anterior region among investigations of anatomical hard tissue parameters based on CT or CBCT scans. In this context, the area between the lateral incisor and the first premolar is the most favorable. However, interroot distance seems to be a critical factor that should be evaluated carefully.
Resumo:
OBJECTIVE To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. METHODS Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. RESULTS Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). CONCLUSION Webcameras have the potential to improve telecommunication of hearing-impaired individuals.
Resumo:
OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.
Resumo:
Purpose: To assess the 5-year survival rate and number of technical, biologic, and esthetic complications involving implant abutments. Materials and Methods: Electronic (Medline) and hand searches were performed to assess studies on metal and ceramic implant abutments. Relevant data from a previous review were included. Two reviewers independently extracted the data. Failure and complication rates were analyzed, and estimates of 5-year survival proportions were calculated from the relationship between event rate and survival function. Multivariable robust Poisson regression was used to compare abutment characteristics. Results: The search yielded 1,558 titles and 274 abstracts. Twenty-four studies were selected for data analysis. The survival rate for ceramic abutments was 97.5% (95% confidence interval [CI]): 89.6% to 99.4%) and 97.6% (95% CI: 96.2% to 98.5%) for metal abutments. The overall 5-year rate for technical complications was 11.8% (95% CI: 8.5% to 16.3%), 8.9% (95% CI: 4.3% to 17.7%) for ceramic and 12.0% (95% CI: 8.5% to 16.8%) for metal abutments. Biologic complications occurred with an overall rate of 6.4% (95% CI: 3.3% to 12.0%), 10.4% (95% CI: 1.9% to 46.7%) for ceramic, and 6.1% (95% CI: 3.1% to 12.0%) for metal abutments. Conclusions: The present meta-analysis on single-implant prostheses presents high survival rates of single implants, abutments, and prostheses after 5 years of function. No differences were found for the survival and failure rates of ceramic and metal abutments. No significant differences were found for technical, biologic, and esthetic complications of internally and externally connected abutments.