153 resultados para Laparoscopic Instrument
Resumo:
Multidimensional talent models represent the current state of the art. However, it remains unclear how these different dimensions interact. Based on current theories of human development, person-oriented approaches seem to be particularly appropriate for talent research. The present study adopts this approach by looking at how a holistic system consisting of the different dimensions motivation, motor behaviour and the stage of development goes along with athletic performance. For this purpose, it has to be examined which patterns were formed by the constructs net hope (Elbe et al., 2003), motor abilities (3 motor tests; Höner et al., 2014), technical skills (3 motor tests; Höner et al., 2014) and the so far achieved percentage of the predicted adult height (Mirwald et al, 2002) and how these patterns are related to subsequent sporting success. 119 young elite football players were questioned and tested three times at intervals of one year, beginning at the age of 12. At the age of 15, the performance level the players had reached was examined (national, regional or no talent card). At all three measuring points, four patterns were identified which displayed partial structural and high individual stability. As expected, the players showing values above average in all factors were significantly more likely to advance to the highest performance level (Odds ratio = 2.2, p < .01). Physically strong, precocious developed players though having some technical weaknesses, have good chances to reach the middle performance level (OR = 1.6, p = .01). Players showing values under average, have an one and a half times higher probability to advance to the lowest performance level (p < .01). The results point to the importance of holistic approaches for the prediction of performance among promising football talents in the medium-term and thus provide valuable clues for their selection and promotion.
Resumo:
STUDY QUESTION: What is the effect of the minimally invasive surgical treatment of endometriosis on health and on quality of work life (e.g. working performance) of affected women? SUMMARY ANSWER: Absence from work, performance loss and the general negative impact of endometriosis on the job are reduced significantly by the laparoscopic surgery. WHAT IS KNOWN ALREADY: The benefits of surgery overall and of the laparoscopic method in particular for treating endometriosis have been described before. However, previous studies focus on medical benchmarks without including the patient's perspective in a quantitative manner. STUDY DESIGN, SIZE, DURATION: A retrospective questionnaire-based survey covering 211 women with endometriosis and a history of specific laparoscopic surgery in a Swiss university hospital, tertiary care center. Data were returned anonymously and were collected from the beginning of 2012 until March 2013. PARTICIPANTS/MATERIALS, SETTING, METHODS: Women diagnosed with endometriosis and with at least one specific laparoscopic surgery in the past were enrolled in the study. The study investigated the effect of the minimally invasive surgery on health and on quality of work life of affected women. Questions used were obtained from the World Endometriosis Research Foundation (WERF) Global Study on Women's Health (GSWH) instrument. The questionnaire was shortened and adapted for the purpose of the present study. MAIN RESULTS AND THE ROLE OF CHANCE: Of the 587 women invited to participate in the study, 232 (232/587 = 40%) returned the questionnaires. Twenty-one questionnaires were excluded due to incomplete data and 211 sets (211/587 = 36%) were included in the study. Our data show that 62% (n = 130) of the study population declared endometriosis as influencing the job during the period prior to surgery, compared with 28% after surgery (P < 0.001). The mean (maximal) absence from work due to endometriosis was reduced from 2.0 (4.9) to 0.5 (1.4) hours per week (P < 0.001). The mean (maximal) loss in working performance after the surgery averaged out at 5.7% (12.6%) compared with 17.5% (30.5%) before this treatment (P < 0.001). LIMITATIONS, REASONS FOR CAUTION: The mediocre response rate of the study weakens the representativeness of the investigated population. Considering the anonymous setting a non-responder investigation was not performed. A bias due to selection, information and negativity effects within a retrospective survey cannot be excluded, although study-sensitive questions were provided in multiple ways. The absence of a control group (sham group; e.g. patients undergoing specific diagnostic laparoscopy without treatment) is a further limitation of the study. WIDER IMPLICATIONS OF THE FINDINGS: Our study shows that indicated minimally invasive surgery has a clear positive effect on the wellbeing and working performance of women suffering from moderate to severe endometriosis. Furthermore, national net savings in indirect costs with the present number of surgeries is estimated to be €10.7 million per year. In an idealized setting (i.e. without any diagnosis delay) this figure could be more than doubled. STUDY FUNDING/COMPETING INTERESTS: The study was performed on behalf of the University Hospital of Bern (Inselspital) as one of the leading Swiss tertiary care centers. The authors do not declare any competing interests.
Resumo:
We report on the developments of a neutron tomography setup at the instrument for prompt gamma-ray activation analysis (PGAA) at the Maier-Leibnitz Zentrum(MLZ). The recent developments are driven by the idea of combining the spatial information obtained with neutron tomography with the elemental information determined with PGAA, i.e. to further combine both techniques to an investigative technique called prompt gamma activation imaging (PGAI).At the PGAA instrument, a cold neutron flux of up to 6 x 1010 cm-2 s-1 (thermal equivalent) is available in the focus of an elliptically tapered neutron guide. In the reported experiments, the divergence of the neutron beam was investigated, the resolution of the installed detector system tested, and a proof-of-principle tomography experiment performed. In our study a formerly used camera box was upgraded with a better camera and an optical resolution of 8 line pairs/mm was achieved. The divergence of the neutron beam was measured by a systematic scan along the beam axis. Based on the acquired data, a neutron imaging setup with a L/D ratio of 200 was installed. The resolution of the setup was testedin combination with a gadolinium test target and different scintillator screens. The test target was irradiated at two positions to determine the maximum resolution and the resolution at the actual sample position. The performance of the installed tomography setup was demonstrated bya tomography experiment of an electric amplifier tube.
Resumo:
PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.
Resumo:
We present cases of 2 pregnant patients with early-stage cervical cancer who have undergone indocyanine green (ICG) sentinel lymph node (SLN) mapping followed by laparoscopic SLN biopsy, pelvic lymphadenectomy, and cervical conization. Eight milliliters of ICG were injected in the 4 quadrants of the cervix after having obtained an adequate pneumoperitoneum and having inspected the abdominal cavity. SLNs were identified in both hemipelvises in both patients. In the final pathologic analysis, both SLNs and non-SLNs were negative for metastatic disease. No adverse events from ICG injection were recorded. ICG SLN mapping seems to be feasible in pregnant cervical cancer patients.
Resumo:
BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.
Resumo:
We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.
Resumo:
Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.
Resumo:
Context. The Rosetta mission of the European Space Agency has been orbiting the comet 67P/Churyumov-Gerasimenko (67P) since August 2014 and is now in its escort phase. A large complement of scientific experiments designed to complete the most detailed study of a comet ever attempted are onboard Rosetta. Aims. We present results for the photometric and spectrophotometric properties of the nucleus of 67P derived from the OSIRIS imaging system, which consists of a Wide Angle Camera (WAC) and a Narrow Angle Camera (NAC). The observations presented here were performed during July and the beginning of August 2014, during the approach phase, when OSIRIS was mapping the surface of the comet with several filters at different phase angles (1.3 degrees-54 degrees). The resolution reached up to 2.1 m/px. Methods. The OSIRIS images were processed with the OSIRIS standard pipeline, then converted into I/F. radiance factors and corrected for the illumination conditions at each pixel using the Lommel-Seeliger disk law. Color cubes of the surface were produced by stacking registered and illumination-corrected images. Furthermore, photometric analysis was performed both on disk-averaged photometry in several filters and on disk-resolved images acquired with the NAC orange filter, centered at 649 ran, using Hapke modeling. Results. The disk-averaged phase function of the nucleus of 67P shows a strong opposition surge with a G parameter value of -0.13 +/- 0.01 in the HG system formalism and an absolute magnitude H-v(1, 1, 0) = 15.74 +/- 0.02 mag. The integrated spectrophotometry in 20 filters covering the 250-1000 nm wavelength range shows a red spectral behavior, without clear absorption bands except for a potential absorption centered at similar to 290 rim that is possibly due to SO2 ice. The nucleus shows strong phase reddening, with disk-averaged spectral slopes increasing from 11%/( 100 nm) to 16%/(100 nm) in the 1.3 degrees-54 degrees phase angle range. The geometric albedo of the comet is 6.5 +/- 0.2% at 649 nm, with local variations of up to similar to 16% in the Hapi region. From the disk-resolved images we computed the spectral slope together with local spectrophotometry and identified three distinct groups of regions (blue, moderately red, and red). The Hapi region is the brightest, the bluest in term of spectral slope, and the most active surface on the comet. Local spectrophotometry shows an enhancement of the flux in the 700-750 nm that is associated with coma emissions.