214 resultados para INTRAVASCULAR ULTRASOUND ELASTOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D ultrasound can be used to study the fetal spine, but skeletal mode can be inconclusive for the diagnosis of fetal spina bifida. We illustrate a diagnostic approach using 2D and 3D ultrasound and indicate possible pitfalls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional (3D) ultrasound volume acquisition, analysis and display of fetal structures have enhanced their visualization and greatly improved the general understanding of their anatomy and pathology. The dynamic display of volume data generally depends on proprietary software, usually supplied with the ultrasound system, and on the operator's ability to maneuver the dataset digitally. We have used relatively simple tools and an established storage, display and manipulation format to generate non-linear virtual reality object movies of prenatal images (including moving sequences and 3D-rendered views) that can be navigated easily and interactively on any current computer. This approach permits a viewing or learning experience that is superior to watching a linear movie passively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endobronchial ultrasound (EBUS) has become a major advance in bronchoscopy. Substantial scientific evidence has confirmed its usefulness in lung cancer diagnosis and staging, as well as in other clinical settings. It is of growing importance that endoscopists perform and interpret this imaging method accurately, in order to optimize diagnosis and treatment of their patients. The present article provides a practical and comprehensible review of the two EBUS systems currently available and its main clinical indications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pelvic pain is a common indication for ultrasound examinations in female pediatric patients. Many pathological processes affect the female pelvis in childhood. Knowledge of the normal ultrasound appearance of the pelvic organs is the basis for the recognition of pathologic findings. Pelvic pain in children is a nonspecific clinical finding often prompting use of ultrasound. Other indications for pelvic ultrasound in female children include workup of cysts seen on fetal ultrasound, urogenital malformations in newborns, precocious puberty, vaginal discharge or abnormal bleeding, and amenorrhea. Knowledge of differential diagnosis for disease processes of the female pelvic organs is essential. Ultrasound is the imaging modality of choice for evaluating the pediatric female pelvis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the usefulness of ultrasound imaging to improve the positioning of the recording needle for nerve conduction studies (NCS) of the sural nerve. METHODS: Orthodromic NCS of the sural nerve was performed in 44 consecutive patients evaluated for polyneuropathy. Ultrasound-guided needle positioning (USNP) was compared to conventional "blind" needle positioning (BNP), electrically guided needle positioning (EGNP), and to recordings with surface electrodes (SFN). RESULTS: The mean distance between the needle tip and the nerve was 1.1 mm with USNP compared to 5.1 mm with BNP (p<0.0001). The mean amplitude of the sensory nerve action potential (SNAP) was 21 microV with USNP and 11 microV with BNP (p<0.0001). Compared to BNP, nerve-needle distances and SNAP amplitudes did not improve with EGNP. SNAP amplitudes recorded with SFN were significantly smaller than with BNP, EGNP and USNP. CONCLUSION: Ultrasound increases the precision of needle positioning markedly, compared to conventional methods. The amplitude of the recorded SNAP is usually clearly greater using USNP. In addition, USNP is faster, less painful and less dependent on the patient. SIGNIFICANCE: USNP is superior to BNP, EGNP, and SFN in accurate measurement of SNAP amplitude. It has a potential use in the routine near-nerve needle sensory NCS of pure sensory nerves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of an intraoperative acute aortic type A dissection (AADA) extending from the distal ascending aorta to the distal aortic arch, initially not visible on the transesophageal echocardiography (TEE). The rapid confirmation of the diagnosis by means of direct epiaortic ultrasound scanning facilitated decision-making and the subsequent successful surgical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very recently, the concept of artificial intracorporeal oxygenation of blood for patients suffering from respiratory failure has been introduced into clinical practice through development of a totally implantable intravascular oxygenator (IVOX). We report on the use of such a device in a patient who developed severe respiratory insufficiency secondary to prolonged hypovolaemic shock and pneumonia following successful repair of a ruptured abdominal aortic aneurysm in September, 1990. Postoperatively, severe hypoxaemia occurred (AaDO2 548-602 torr) despite extensive mechanical ventilatory support. There was no obvious chance to overcome this situation by conventional therapeutic measures and the decision was made to institute IVOX therapy. Hypoxaemia was resolved immediately and both FiO2 and tidal volume could be reduced within hours. The patient's respiratory condition continued to improve over the next days leading to termination of IVOX therapy after 71 hours. However, the necessity of long-term ventilatory support secondary to recurrent pneumonia and sepsis, multiple abdominal reoperations for ischemic colitis and retroperitoneal abscess prolonged his recovery. He was discharged from the hospital after four months and is alive and well now 14 months after his operation. He is the first long-term survivor after IVOX therapy in Europe. IVOX may be successfully used in selected patients while the indications and it's potential role in the therapy of severe respiratory failure still need to be defined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Severe acute respiratory failure of varying etiology may require the temporary use of artificial gas exchange devices. So far, extracorporeal membrane oxygenation and extracorporeal carbon dioxide removal have been used successfully for this purpose. A totally implantable intravascular oxygenator (IVOX) recently became available. The authors have used IVOX in three patients who presented with severe respiratory failure secondary to pneumonia (n = 2) and post-traumatic adult respiratory distress syndrome (n = 1). At the time of implantation, all patients had hypoxemia (PaO2 less than 60) despite a 100% inspired oxygen concentration and forced mechanical ventilation. The duration of IVOX therapy ranged from 12 to 71 hr. All patients initially showed improvement in arterial oxygenation, allowing for moderate reduction of ventilator therapy after several hours. In one patient the pulmonary status deteriorated further, and she died from multiple organ failure despite IVOX therapy. One patient could be stabilized but died from other causes. The third patient is a long-term survivor 18 months after IVOX therapy. Gas transfer capabilities of IVOX are limited when compared to extracorporeal membrane oxygenation, and this may restrict its clinical applicability in cases of severe adult respiratory distress syndrome. However, IVOX may be used successfully in selected patients with less severe respiratory failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: The aim of this study was to examine mechanical, microbiologic, and morphologic changes of the appendicle rim to assess if it is appropriate to dissect the appendix with the ultrasound-activated scalpel (UAS) during laparoscopic appendectomy. Materials and Methods: After laparoscopic resection of the appendix, using conventional Roeder slings, we investigated 50 appendicle rims with an in vitro procedure. The overall time of dissection of the mesoappendix with UAS was noted. Following removal, the appendix was dissected in vitro with the UAS one cme from the resection rim. Seal-burst pressures were recorded. Bacterial cultures of the UAS-resected rim were compared with those of the scissors resected rim. Tissue changes were quantified histologically with hematoxylin and eosin (HE) stains. Results: The average time to dissect the mesoappendix was 228 seconds (25-900). Bacterial culture growths were less in the UAS-resected probes (7 versus 36 positive probes; (p > 0.01). HE-stained tissues revealed mean histologic changes in the lamina propria muscularis externa of 2 mm depth. The seal-burst pressure levels of the appendicle lumen had a mean of 420 mbar. Seal-burst pressures and depths of histologic changes were not dependent on the different stages of appendicitis investigated, gender, or age groups. Seal-burst pressure levels were not related to different depths of tissue changes (P = 0.64). Conclusions: The UAS is a rapid instrument for laparoscopic appendectomy and appears to be safe with respect to stability, sterility and tissue changes. It avoids complex time consuming instrument change manoeuvres and current transmission, which may induce intra- and postoperative complications. Our results suggest that keeping a safety margin of at least 5 mm from the bowel would be sufficient to avoid thermal damage.