139 resultados para GRAFT FIXATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

After organ transplantation, recipient T cells contribute to graft rejection. Mesenchymal stromal cells from the bone marrow (BM-MSCs) are known to suppress allogeneic T-cell responses, suggesting a possible clinical application of MSCs in organ transplantation. Human liver grafts harbor resident populations of MSCs (L-MSCs). We aimed to determine the immunosuppressive effects of these graft-derived MSCs on allogeneic T-cell responses and to compare these with the effects of BM-MSCs. BM-MSCs were harvested from aspirates and L-MSCs from liver graft perfusates. We cultured them for 21 days and compared their suppressive effects with the effects of BM-MSCs on allogeneic T-cell responses. Proliferation, cytotoxic degranulation, and interferon-gamma production of alloreactive T cells were more potently suppressed by L-MSCs than BM-MSCs. Suppression was mediated by both cell-cell contact and secreted factors. In addition, L-MSCs showed ex vivo a higher expression of PD-L1 than BM-MSCs, which was associated with inhibition of T-cell proliferation and cytotoxic degranulation in vitro. Blocking PD-L1 partly abrogated the inhibition of cytotoxic degranulation by L-MSCs. In addition, blocking indoleamine 2,3-dioxygenase partly abrogated the inhibitive effects of L-MSCs, but not BM-MSCs, on T-cell proliferation. In conclusion, liver graft-derived MSC suppression of allogeneic T-cell responses is stronger than BM-MSCs, which may be related to in situ priming and mobilization from the graft. These graft-derived MSCs may therefore be relevant in transplantation by promoting allohyporesponsiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vein grafts are still the most commonly used graft material in cardiovascular surgery and much effort has been spent in recent years on investigating the optimal harvesting technique. One other related topic of similar importance remained more or less an incidental one. The storage solutions of vein grafts following procurement and prior to implantation are, despite their assumed impact, a relatively neglected theme. There is no doubt that the endothelium plays a key role in long-term patency of vein grafts, but the effects of the different storage solutions on the endothelium remain unclear : In a review of the literature, we could find 20 specific papers that addressed the question, of which the currently available preservation solutions are superior, harmless, damaging or ineffective. The focus lies on saline and autologous whole blood. Besides these two storage media, novel or alternative solutions have been investigated with surprising findings. In addition, a few words will be spent on potential alternatives and novel solutions on the market. As there is currently no randomized clinical trial regarding saline versus autologous whole blood available, this review compares all previous studies and methods of analysis to provide a certain level of evidence on this topic. In summary, saline has negative effects on the endothelial layers and therefore may compromise graft patency. Related factors, such as distension pressure, may outbalance the initial benefit of autologous whole blood or storage solutions and intensify the harmful effects of warm saline. In addition, there is no uniform consent on the superiority of autologous whole blood for vein graft storage. This may open the door to alternatives such as the University of Wisconsin solution or one of the specific designed storage solutions like TiProtec™ or Somaluthion™. Whether these preservation solutions are superior or advantageous remains the subject of further studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.