297 resultados para CT angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n=9), ruptured aneurysm (n=6), ruptured arteriovenous malformation (n=2), and spontaneous bleeding (n=8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. RESULTS: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. CONCLUSIONS: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the effect of tumor size and tumor-to-liver contrast of simulated hypovascular liver tumors on the diagnostic accuracy of hepatic computed tomography (CT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Outcome of stroke patients selected with cerebral computed tomography for intravenous thrombolysis administered in clinical routine from 3 to 4.5 hours after symptoms onset is not well investigated. Aim of this single-center, prospective, observational study was to compare the safety and efficacy of intravenous alteplase given in routine clinical praxis 181-270 minutes (late) and within 180 minutes (early) after stroke onset in patients selected with cerebral computed tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the fact that numerous studies pursued the strategy of improving collateral function in patients with peripheral artery disease (PAD), there is currently no method available to quantify collateral arterial function of the lower limb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Perfusion CT (P-CT) is used for acute stroke management, not, however, for evaluating epilepsy. To test the hypothesis that P-CT may identify patients with increased regional cerebral blood flow during subtle status epilepticus (SSE), we compared P-CT in SSE to different postictal conditions. METHODS: Fifteen patients (mean age 47 years, range 21-74) underwent P-CT immediately after evaluation in our emergency room. Asymmetry indices between affected and unaffected hemispheres were calculated for regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and mean transit time (MTT). Regional perfusion changes were compared to EEG findings. RESULTS: Three patients in subtle status epilepticus (group 1) had increased regional perfusion with electro-clinical correlate. Six patients showed postictal slowing on EEG corresponding to an area of regional hypoperfusion (group 2). CT and EEG were normal in six patients with a first epileptic seizure (group 3). Cluster analysis of asymmetry indices separated SSE from the other two groups in all three parameters, while rCBF helped to distinguish between chronic focal epilepsies and single events. CONCLUSION: Preliminary results indicate that P-CT may help to identify patients with SSE during emergency workup. This technique provides important information to neurologists or emergency physicians in the difficult clinical differential diagnosis of altered mental status due to subtle status epilepticus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emergency CT examination is considered to be a trade-off between a short scan time and the acceptance of artifacts. This study evaluates the influence of patient repositioning on artifacts and scan time. Eighty-three consecutive multiple-trauma patients were included in this prospective study. Patients were examined without repositioning (group 1, n=39) or with patient rotation to feet-first with arms raised for scanning the chest and abdomen/pelvis (group 2, n=44). The mean scan time was 21 min in group 1 and 25 min in group 2 (P=0.01). The mean repositioning time in group 2 was 8 min. Significantly, more artifacts were observed in group 1 (with a repeated scan in 7%) than in group 2 (P=0.0001). This novel multiple- trauma CT-scanning protocol with patient repositioning achieves a higher image quality with significantly fewer artifacts than without repositioning but increases scan time slightly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mild traumatic brain injury (MTBI) defined as Glasgow Coma Scale (GCS) 14 or 15 has shown contradictory short- and long-term outcomes. The objective of this study was to correlate intra-cranial injuries (ICI) on CT scan to neurocognitive tests at admission and to complaints after 1 year. METHODS: Two hundred and five patients with MTBI underwent a CT scan and were examined with neurocognitive tests. After 1 year complaints were assessed by phone interviews. RESULTS: The neurocognitive tests in 51% of the patients showed significant deficits; there was no difference for patients with GCS 14-15, nor was there a difference between patients with ICI to patients without. After 1 year patients with ICI had significantly more complaints than patients without ICI, the most frequent complaint was headache and memory deficits. CONCLUSIONS: No correlation was found between GCS or ICI and the neurocognitive tests upon admission. After 1 year, patients with ICI have significantly more complaints than patients without ICI. No cost savings resulted by doing immediate CT scan on all.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Besides DNA, dental radiographs play a major role in the identification of victims in mass casualties or in corpses with major postmortem alterations. Computed tomography (CT) is increasingly applied in forensic investigations and is used to scan the dentition of deceased persons within minutes. We investigated different restoration materials concerning their radiopacity in CT for dental identification purposes. METHODS: Extracted teeth with different filling materials (composite, amalgam, ceramic, temporary fillings) were CT scanned. Radiopacities of the filling materials were analyzed in extended CT scale images. RESULTS: Radiopacity values ranged from 6000-8500HU (temporary fillings), 4500-17000HU (composite fillings) and >30710HU (Amalgam and Gold). The values were used to define presets for a 3D colored volume rendering software. CONCLUSIONS: The effects of filling material caused streak artifacts could be distinctively reduced for the assessment of the dental status and a postprocessing algorithm was introduced that allows for 3D color encoded visualization and discrimination of different dental restorations based on postmortem CT data.