263 resultados para ATRIAL FIBRILLATION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). METHODS: Male participants of a 10-mile race were recruited and included if office blood pressure was normal (<140/90 mmHg). Athletes were stratified into a masked hypertension and normotension group by ambulatory blood pressure. Primary endpoint was diastolic function, expressed as peak early diastolic mitral annulus velocity (E'). Left ventricular global strain, left ventricular mass/volume ratio, left atrial volume index, signal-averaged P-wave duration (SAPWD), and SVT during 24-h Holter monitoring were recorded. RESULTS: From 108 runners recruited, 87 were included in the final analysis. Thirty-three (38%) had masked hypertension. The mean age was 42 +/- 8 years. Groups did not differ with respect to age, body composition, cumulative training hours, and 10-mile race time. Athletes with masked hypertension had a lower E' and a higher left ventricular mass/volume ratio. Left ventricular global strain, left atrial volume index, SAPWD, and SVT showed no significant differences between the groups. In multiple linear regression analysis, masked hypertension was independently associated with E' (beta = -0.270, P = 0.004) and left ventricular mass/volume ratio (beta = 0.206, P = 0.049). Cumulative training hours was the only independent predictor for left atrial volume index (beta = 0.474, P < 0.001) and SAPWD (beta = 0.481, P < 0.001). CONCLUSION: In our study, a relevant proportion of middle-aged athletes had masked hypertension, associated with a lower diastolic function and a higher left ventricular mass/volume ratio, but unrelated to left ventricular systolic function, atrial remodeling, or SVT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We read with great interest the large-scale network meta-analysis by Kowalewski et al. comparing clinical outcomes of patients undergoing coronary artery bypass grafting (CABG) operated on using minimal invasive extracorporeal circulation (MiECC) or off-pump (OPCAB) with those undergoing surgery on conventional cardiopulmonary bypass (CPB) [1]. The authors actually integrated into single study two recently published meta-analysis comparing MiECC and OPCAB with conventional CPB, respectively [2, 3] into a single study. According to the results of this study, MiECC and OPCAB are both strongly associated with improved perioperative outcomes following CABG when compared with CABG performed on conventional CPB. The authors conclude that MiECC may represent an attractive compromise between OPCAB and conventional CPB. After carefully reading the whole manuscript, it becomes evident that the role of MiECC is clearly undervalued. Detailed statistical analysis using the surface under the cumulative ranking probabilities indicated that MiECC represented the safer and more effective intervention regarding all-cause mortality and protection from myocardial infarction, cerebral stroke, postoperative atrial fibrillation and renal dysfunction when compared with OPCAB. Even though no significant statistical differences were demonstrated between MiECC and OPCAB, the superiority of MiECC is obvious by the hierarchy of treatments in the probability analysis, which ranked MiECC as the first treatment followed by OPCAB and conventional CPB. Thus, MiECC does not represent a compromise between OPCAB and conventional CPB, but an attractive dominant technique in CABG surgery. These results are consistent with the largest published meta-analysis by Anastasiadis et al. comparing MiECC versus conventional CPB including a total of 2770 patients. A significant decrease in mortality was observed when MiECC was used, which was also associated with reduced risk of postoperative myocardial infarction and neurological events [4]. Similarly, another recent meta-analysis by Benedetto et al. compared MiECC versus OPCAB and resulted in comparable outcomes between these two surgical techniques [5]. As stated in the text, superiority of MiECC observed in the current network meta-analysis, when compared with OPCAB, could be attributed to the fact that MiECC offers the potential for complete revascularization, whereas OPCAB poses a challenge for unexperienced surgeons; especially when distal marginal branches on the lateral and/or posterior wall of the heart need revascularization. This is reflected by a significantly lower number of distal anastomoses performed in OPCAB when compared with conventional CPB. Therefore, taking into consideration the literature published up to date, including the results of the current article, we advocate that MiECC should be integrated in the clinical practice guidelines as a state-of-the-art technique and become a standard practice for perfusion in coronary revascularization surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The clinical and demographic characteristics of patients undergoing TAVI pose unique challenges for developing and implementing optimal antithrombotic therapy. Ischaemic and bleeding events in the periprocedural period and months after TAVI still remain a relevant concern to be faced with optimised antithrombotic therapy. Moreover, the antiplatelet and anticoagulant pharmacopeia has evolved significantly in recent years with new drugs and multiple possible combinations. Dual antiplatelet therapy (DAPT) is currently recommended after TAVI with oral anticoagulation (OAC) restricted for specific indications. However, atrial fibrillation (which is often clinically silent and unrecognised) is common after the procedure and embolic material often thrombin-rich. Recent evidence has therefore questioned this approach, suggesting that DAPT may be futile compared with aspirin alone and that OAC could be a relevant alternative. Future randomised and appropriately powered trials comparing different regimens of antithrombotic therapy, including new antiplatelet and anticoagulant agents, are warranted to increase the available evidence on this topic and create appropriate recommendations for this frail population. Meanwhile, it remains rational to adhere to current guidelines, with routine DAPT and recourse to OAC when specifically indicated, whilst always tailoring therapy on the basis of individual bleeding and thromboembolic risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Permanent destruction of abnormal cardiac tissue responsible for cardiac arrhythmogenesis whilst avoiding collateral tissue injury forms the cornerstone of catheter ablation therapy. As the acceptance and performance of catheter ablation increases worldwide, limitations in current technology are becoming increasingly apparent in the treatment of complex arrhythmias such as atrial fibrillation. This review will discuss the role of new technologies aimed to improve lesion formation with the ultimate goal of improving arrhythmia-free survival of patients undergoing catheter ablation of atrial arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial flutter in the donor part of orthotopic heart transplants has been reported and successfully treated by radiofrequency ablation of the cavotricuspid isthmus, but mapping and ablation of atypical flutter circuits may be challenging.(1) Entrainment mapping has been used in combination with activation mapping to define the mechanism of atypical atrial flutter. Here, we report a case where colour-coded three-dimensional (3D) entrainment mapping allowed us to accurately determine and visualize the 3D location of the reentrant circuit and to plan the ablation of a left atrial flutter without the need for activation mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a 55-year-old woman is presented, whose clinical signs were initially suggestive of infective endocarditis. Transthoracic echocardiography (TTE) provided the diagnosis of a large left atrial myxoma attached to the anterior mitral leaflet. Perioperative transesophageal echocardiography (TEE) confirmed preoperative findings and assisted the surgical team in the assessment of tumour size, area of attachment, and mobility. Following tumour resection, TEE demonstrated residual moderate mitral valve regurgitation, which resulted in a change of surgical strategy. This report reinforces the importance of intraoperative TEE to facilitate and optimize surgical and anaesthesiological management of patients presenting with non-specific cardiorespiratory symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess cardiac morphologic and functional adaptations in elite triathletes with magnetic resonance (MR) imaging and to compare findings to those in recreationally active control subjects.