72 resultados para skull


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the occurrence, sites, and types of associated injuries in paediatric patients with fractures of the anterior skull base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Homicides with a survival of several days are not uncommon in forensic routine work. Reconstructions of these cases by autopsy alone are very difficult and may occasionally lead to unsatisfying results. For the medico-legal reconstruction of these cases, ante-mortem and post-mortem radiological imaging should always be included in the expertise. We report on a case of fatal penetrating stab wounds to the skull in which a case reconstruction was only possible by combining the radiological ante- and post-mortem data with the autopsy findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONCLUSION: Our self-developed planning and navigation system has proven its capacity for accurate surgery on the anterior and lateral skull base. With the incorporation of augmented reality, image-guided surgery will evolve into 'information-guided surgery'. OBJECTIVE: Microscopic or endoscopic skull base surgery is technically demanding and its outcome has a great impact on a patient's quality of life. The goal of the project was aimed at developing and evaluating enabling navigation surgery tools for simulation, planning, training, education, and performance. This clinically applied technological research was complemented by a series of patients (n=406) who were treated by anterior and lateral skull base procedures between 1997 and 2006. MATERIALS AND METHODS: Optical tracking technology was used for positional sensing of instruments. A newly designed dynamic reference base with specific registration techniques using fine needle pointer or ultrasound enables the surgeon to work with a target error of < 1 mm. An automatic registration assessment method, which provides the user with a color-coded fused representation of CT and MR images, indicates to the surgeon the location and extent of registration (in)accuracy. Integration of a small tracker camera mounted directly on the microscope permits an advantageous ergonomic way of working in the operating room. Additionally, guidance information (augmented reality) from multimodal datasets (CT, MRI, angiography) can be overlaid directly onto the surgical microscope view. The virtual simulator as a training tool in endonasal and otological skull base surgery provides an understanding of the anatomy as well as preoperative practice using real patient data. RESULTS: Using our navigation system, no major complications occurred in spite of the fact that the series included difficult skull base procedures. An improved quality in the surgical outcome was identified compared with our control group without navigation and compared with the literature. The surgical time consumption was reduced and more minimally invasive approaches were possible. According to the participants' questionnaires, the educational effect of the virtual simulator in our residency program received a high ranking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the anterior skull base and fronto-orbital framework following extensive tumor resection is both challenging and controversial. Dural defects are covered with multiple sheets of fascia lata that provide sufficient support and avoid herniation. Plating along the skull base is contraindicated. After resection of orbital walls, grafting is necessary if the periosteum or parts of the periorbital tissue had to be removed, to avoid enophthalmus or strabism. Free bone grafts exposed to the sinonasal or pharyngeal cavity are vulnerable to infection or necrosis: therefore, covering the grafts with vascularized tissue, such as the Bichat fat-pad or pedicled temporalis flaps, should reduce these complications. Alloplastic materials are indispensable in cranial defects, whereas microsurgical free tissue transfer is indicated in cases of orbital exenteration and skin defects. The authors review their experience and follow-up of 122 skull base reconstructions following extensive subcranial tumor resection. Most significant complications were pneumocranium in 4.9%, CSF leaks in 3.2%, and partial bone resorption in 8.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open skull fractures have been traditionally managed in 2 stages: urgent craniotomy and elevation of the fracture with removal of contaminated bone, debridement, and delayed cranioplasty. Primary, single-stage repair of these injures has been said to entail risks such as infections. Recent experience, however, disproved these concerns.We used a primary single-stage reconstruction for patients presenting with open depressed skull fractures. All patients received antibiotic prophylaxis. The patients underwent elevation of the compound fracture and craniotomy if necessary. Debridement was performed, followed by skull reconstruction using a 0.6-mm titanium mesh.We present 5 consecutive male patients (age, 32.2 +/- 15.6 years) who underwent primary reconstruction of open depressed skull fractures. Clinical and radiologic follow-up was performed 2 months after surgery. The duration of the surgery was 2 +/- 1.6 hours. The size of the implanted mesh was 13 +/- 13.1 cm. No infection was detected in our series, with a follow-up period of 22 +/- 6.5 months (range, 16-29 months). The cosmetic result was defined in 4 patients as "excellent" and in 1 patient as "good."Primary reconstruction of open skull fractures with titanium mesh is feasible, safe, and cosmetically preferable than the conventional staged approach. The introduction into clinical practice can be warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endoscopic or microscopic surgery for chronic rhinosinusitis with or without nasal polyps is a routine intervention in daily practice. It is often a delicate and difficult minimally invasive intervention in a narrow space, with a tunnel view of 4 mm in the case of endoscopy and frequent bleeding in chronically inflamed tissue. Therefore, orientation in such a "labyrinth" is often difficult. In the case of polyp recurrence or tumors, the normal anatomical landmarks are often missing, which renders orientation even more difficult. In such cases, computer-aided navigation together with images such as those from computed tomography or magnetic resonance imaging can support the surgeon to make the operation more accurate and, in some cases, faster. Computer-aided surgery also has great potential for education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Beer bottles are often used in physical disputes. If the bottles break, they may give rise to sharp trauma. However, if the bottles remain intact, they may cause blunt injuries. In order to investigate whether full or empty standard half-litre beer bottles are sturdier and if the necessary breaking energy surpasses the minimum fracture-threshold of the human skull, we tested the fracture properties of such beer bottles in a drop-tower. Full bottles broke at 30 J impact energy, empty bottles at 40 J. These breaking energies surpass the minimum fracture-threshold of the human neurocranium. Beer bottles may therefore fracture the human skull and therefore serve as dangerous instruments in a physical dispute.