72 resultados para retention curve


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A water desaturation zone develops around a tunnel in water-saturated rock when the evaporative water loss at the rock surface is larger than the water flow from the surrounding saturated region of restricted permeability. We describe the methods with which such water desaturation processes in rock materials can be quantified. The water retention characteristic theta(psi) of crystalline rock samples was determined with a pressure membrane apparatus. The negative water potential, identical to the capillary pressure, psi, below the tensiometric range (psi < -0.1 MPa) can be measured with thermocouple psychrometers (TP), and the volumetric water contents, theta, by means of time domain reflectometry (TDR). These standard methods were adapted for measuring the water status in a macroscopically unfissured granodiorite with a total porosity of approximately 0.01. The measured water retention curve of granodiorite samples from the Grimsel test site (central Switzerland) exhibits a shape which is typical for bimodal pore size distributions. The measured bimodality is probably an artifact of a large surface ratio of solid/voids. The thermocouples were installed without a metallic screen using the cavity drilled into the granodiorite as a measuring chamber. The water potentials observed in a cylindrical granodiorite monolith ranged between -0.1 and -3.0 MPa; those near the wall in a ventilated tunnel between -0.1 and -2.2 MPa. Two types of three-rod TDR Probes were used, one as a depth probe inserted into the rock, the other as a surface probe using three copper stripes attached to the surface for detecting water content changes in the rock-to-air boundary. The TDR signal was smoothed with a low-pass filter, and the signal length determined based on the first derivative of the trace. Despite the low porosity of crystalline rock these standard methods are applicable to describe the unsaturated zone in solid rock and may also be used in other consolidated materials such as concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wild-type cholecystokinin type 2 (CCK(2)) receptor is expressed in many gastrointestinal and lung tumours. A splice variant of the CCK(2) receptor with retention of intron 4 (CCK(2)Ri4sv) showing constitutive activity associated with increased tumour growth was described in few colorectal, pancreatic and gastric cancers. Given the potential functional and clinical importance of this spliceoform, its occurrence was quantitatively characterized in a broad collection of 81 gastrointestinal and lung tumours, including insulinomas, ileal carcinoids, gastrointestinal stromal tumours (GIST), gastric, colorectal and pancreatic ductal adenocarcinomas, cholangiocellular and hepatocellular carcinomas, small cell lung cancers (SCLC), non-SCLC (nSCLC) and bronchopulmonary carcinoids, as well as 21 samples of corresponding normal tissues. These samples were assessed for transcript expression of total CCK(2) receptor, wild-type CCK(2) receptor and CCK(2)Ri4sv with end-point and real-time RT-PCR, and for total CCK(2) receptor protein expression on the basis of receptor binding with in vitro receptor autoradiography. Wild-type CCK(2) receptor transcripts were found in the vast majority of tumours and normal tissues. CCK(2)Ri4sv mRNA expression was present predominantly in insulinomas (incidence 100%), GIST (100%) and SCLC (67%), but rarely in pancreatic, colorectal and gastric carcinomas and nSCLC. It was not found in wild-type CCK(2) receptor negative tumours or any normal tissues tested. CCK(2)Ri4sv transcript levels in individual tumours were low, ranging from 0.02% to 0.14% of total CCK(2) receptor transcripts. In conclusion, the CCK(2)Ri4sv is a marker of specific gastrointestinal and lung tumours. With its high selectivity for and high incidence in SCLC and GIST, it may represent an attractive clinical target.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the wear behavior of conical crowns of gold alloy and zirconium dioxide ceramics facing electroplated gold copings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Out-of-hospital emergency physicians in Austria need mandatory emergency physician training, followed by biennial refresher courses. Currently, both standardized ERC advanced life support (ALS) provider courses and conventional refresher courses are offered. This study aimed to compare the retention of ALS-knowledge of out-of-hospital emergency physicians depending on whether they had or had not participated in an ERC-ALS provider course since 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Airway management for successful ventilation by laypersons and inexperienced healthcare providers is difficult to achieve. Bag-valve mask (BVM) ventilation requires extensive training and is performed poorly. Supraglottic airway devices (SADs) have been successfully introduced to clinical resuscitation practice as an alternative. We evaluated recently introduced (i-gel™ and LMA-Supreme™) and established SADs (LMA-Unique™, LMA-ProSeal™) and BVM used by laypeople in training sessions on manikins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest into the effects of carnosine on cellular metabolism is rapidly expanding. The first study to demonstrate in humans that chronic β-alanine (BA) supplementation (~3-6 g BA/day for ~4 weeks) can result in significantly augmented muscle carnosine concentrations (>50%) was only recently published. BA supplementation is potentially poised for application beyond the niche exercise and performance-enhancement field and into other more clinical populations. When examining all BA supplementation studies that directly measure muscle carnosine (n=8), there is a significant linear correlation between total grams of BA consumed (of daily intake ranges of 1.6-6.4 g BA/day) versus both the relative and absolute increases in muscle carnosine. Supporting this, a recent dose-response study demonstrated a large linear dependency (R2=0.921) based on the total grams of BA consumed over 8 weeks. The pre-supplementation baseline carnosine or individual subjects' body weight (from 65 to 90 kg) does not appear to impact on subsequent carnosine synthesis from BA consumption. Once muscle carnosine is augmented, the washout is very slow (~2%/week). Recently, a slow-release BA tablet supplement has been developed showing a smaller peak plasma BA concentration and delayed time to peak, with no difference in the area under the curve compared to pure BA in solution. Further, this slow-release profile resulted in a reduced urinary BA loss and improved retention, while at the same time, eliciting minimal paraesthesia symptoms. However, our complete understanding of optimizing in vivo delivery and dosing of BA is still in its infancy. Thus, this review will clarify our current knowledge of BA supplementation to augment muscle carnosine as well as highlight future research questions on the regulatory points of control for muscle carnosine synthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data from observational cohorts may be influenced by population structure and loss to follow-up (LTFU). Quality of care may be associated with participation in cohort networks. We aimed to study the participation, characteristics and retention rates of immigrants in the Swiss HIV Cohort Study (SHCS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the wear behavior of conical crowns with electroplated gold copings that are used to connect implants and teeth to a removable denture. Gold alloy and zirconium dioxide ceramic crowns were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retention of overdentures is important for patients' satisfaction. The study tested whether the clinical performance of retentive clips made of poly-ether-ether-ketone (PEEK) is superior to those made of poly-oxy-methylene (POM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study deals with the determination of the retentive forces of telescopic crowns measured extra- and intra-orally and the correlation of these values.