99 resultados para drug analysis
Resumo:
Injecting drug use (IDU) before and after liver transplantation (LT) is poorly described. The aim of this study was to quantify relapse and survival in this population and to describe the causes of mortality after LT.
Resumo:
Differentiation between external contamination and incorporation of drugs or their metabolites from inside the body via blood, sweat or sebum is a general issue in hair analysis and of high concern when interpreting analytical results. In hair analysis for cannabinoids the most common target is Delta9-tetrahydrocannabinol (THC), sometimes cannabidiol (CBD) and cannabinol (CBN) are determined additionally. After repeated external contamination by cannabis smoke these analytes are known to be found in hair even after performing multiple washing steps. A widely accepted strategy to unequivocally prove active cannabis consumption is the analysis of hair extracts for the oxidative metabolite 11-nor-9-carboxy-THC (THC-COOH). Although the acidic nature of this metabolite suggests a lower rate of incorporation into the hair matrix compared to THC, it is not fully understood up to now why hair concentrations of THC-COOH are generally found to be much lower (mostly <10 pg/mg) than the corresponding THC concentrations. Delta9-Tetrahydrocannabinolic acid A (THCA A) is the preliminary end product of the THC biosynthesis in the cannabis plant. Unlike THC it is non-psychoactive and can be regarded as a 'precursor' of THC being largely decarboxylated when heated or smoked. The presented work shows for the first time that THCA A is not only detectable in blood and urine of cannabis consumers but also in THC positive hair samples. A pilot experiment performed within this study showed that after oral intake of THCA A on a regular basis no relevant incorporation into hair occurred. It can be concluded that THCA A in hair almost exclusively derives from external contamination e.g. by side stream smoke. Elevated temperatures during the analytical procedure, particularly under alkaline conditions, can lead to decarboxylation of THCA A and accordingly increase THC concentrations in hair. Additionally, it has to be kept in mind that in hair samples tested positive for THCA A at least a part of the 'non-artefact' THC probably derives from external contamination as well, because in condensate of cannabis smoke both THC and THCA A are present in relevant amounts. External contamination by side stream smoke could therefore explain the great differences in THC and THC-COOH hair concentrations commonly found in cannabis users.
Resumo:
Unexplained differences between classes of antihypertensive drugs in their effectiveness in preventing stroke might be due to class effects on intraindividual variability in blood pressure. We did a systematic review to assess any such effects in randomised controlled trials.
Resumo:
The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).
Resumo:
The chemotherapeutic drug 5-fluorouracil (5-FU) is widely used for treating solid tumors. Response to 5-FU treatment is variable with 10-30% of patients experiencing serious toxicity partly explained by reduced activity of dihydropyrimidine dehydrogenase (DPD). DPD converts endogenous uracil (U) into 5,6-dihydrouracil (UH(2) ), and analogously, 5-FU into 5-fluoro-5,6-dihydrouracil (5-FUH(2) ). Combined quantification of U and UH(2) with 5-FU and 5-FUH(2) may provide a pre-therapeutic assessment of DPD activity and further guide drug dosing during therapy. Here, we report the development of a liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of U, UH(2) , 5-FU and 5-FUH(2) in human plasma. Samples were prepared by liquid-liquid extraction with 10:1 ethyl acetate-2-propanol (v/v). The evaporated samples were reconstituted in 0.1% formic acid and 10 μL aliquots were injected into the HPLC system. Analyte separation was achieved on an Atlantis dC(18) column with a mobile phase consisting of 1.0 mm ammonium acetate, 0.5 mm formic acid and 3.3% methanol. Positively ionized analytes were detected by multiple reaction monitoring. The analytical response was linear in the range 0.01-10 μm for U, 0.1-10 μm for UH(2) , 0.1-75 μm for 5-FU and 0.75-75 μm for 5-FUH(2) , covering the expected concentration ranges in plasma. The method was validated following the FDA guidelines and applied to clinical samples obtained from ten 5-FU-treated colorectal cancer patients. The present method merges the analysis of 5-FU pharmacokinetics and DPD activity into a single assay representing a valuable tool to improve the efficacy and safety of 5-FU-based chemotherapy.
Resumo:
Patients with panic disorder (PD) have a bias to respond to normal stimuli in a fearful way. This may be due to the preactivation of fear-associated networks prior to stimulus perception. Based on EEG, we investigated the difference between patients with PD and normal controls in resting state activity using features of transiently stable brain states (microstates). EEGs from 18 drug-naive patients and 18 healthy controls were analyzed. Microstate analysis showed that one class of microstates (with a right-anterior to left-posterior orientation of the mapped field) displayed longer durations and covered more of the total time in the patients than controls. Another microstate class (with a symmetric, anterior-posterior orientation) was observed less frequently in the patients compared to controls. The observation that selected microstate classes differ between patients with PD and controls suggests that specific brain functions are altered already during resting condition. The altered resting state may be the starting point of the observed dysfunctional processing of phobic stimuli.
Resumo:
The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents.
Resumo:
Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents.
Resumo:
Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.
Resumo:
BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.
Resumo:
BACKGROUND There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis. RESULTS Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio=0.95, 95% CI=0.74-1.21, P=0.67). Target lesion revascularization was also comparable between the groups (hazard ratio=0.89, 95% CI=0.65-1.22, P=0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio=0.52, 95% CI=0.28-0.96, P=0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4years (hazard ratio=0.15, 95% CI=0.03-0.70, P=0.02). CONCLUSIONS In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4years. Rates of stent thrombosis were significantly lower with BP-DES.
Resumo:
OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Resumo:
BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.
Resumo:
BACKGROUND Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes--including death and myocardial infarction (MI)--in clinical studies. OBJECTIVES To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). DESIGN Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. SETTING Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrollment criteria were generally unrestrictive. PATIENTS 5130 patients. MAIN OUTCOME MEASURES 2-year clinical outcomes and 13-month angiographic outcomes. RESULTS 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES. CONCLUSIONS Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes--including repeat revascularisation--to non-overlapping DES.