146 resultados para center
Resumo:
PURPOSE: To evaluate the use of covered stent-grafts in the endovascular treatment (ET) of popliteal artery aneurysms (PAAs). MATERIALS AND METHODS: A retrospective analysis was conducted over a period of 52 months in 18 consecutive patients (17 men; mean age +/- SD, 70 years +/- 11) undergoing ET of PAAs with the Viabahn endograft in a single center. Patient symptoms, aneurysm characteristics, technical outcomes, complications, and follow-up were assessed. RESULTS: Aneurysm diameters ranged from 12 to 51 mm with a mean of 30 mm (+/-11). Thirteen aneurysms (72.2%) were partially thrombosed and 12 patients (66.6%) had symptoms of lower limb ischemia at presentation (11 chronic and one acute). The technical success rate was 94%. Intraprocedural emboli and endoleak occurred in one and two patients, respectively. Fourteen patients were available for follow-up after successful treatment, with a mean follow-up time of 15 months (range, 7-37 months). All stent-grafts were patent after 1 month, with no mortality or limb loss. The primary patency rate with complete exclusion of the aneurysm at 6 months was 86%. Pre- and postprocedural noninvasive arterial studies were available in 10 patients, demonstrating improvement of the ankle-brachial index from 0.96 +/- 0.41 to 1.17 +/- 0.18, respectively (P = .06). CONCLUSIONS: Endovascular stent-graft repair of PAAs is a feasible treatment option. However, further follow-up studies regarding the durability of results are required.
Resumo:
To assess safety and efficacy of tailored total lymphoid irradiation (tTLI) in cardiac transplant patients.
Resumo:
OBJECTIVE: To compare and evaluate longitudinally the dental arch relationships from 4.5 to 13.5 years of age with the Bauru-BCLP Yardstick in a large sample of patients with bilateral cleft lip and palate (BCLP). DESIGN: Retrospective longitudinal intercenter outcome study. PATIENTS: Dental casts of 204 consecutive patients with complete BCLP were evaluated at 6, 9, and 12 years of age. All models were identified only by random identification numbers. SETTING: Three cleft palate centers with different treatment protocols. MAIN OUTCOME MEASURES: Dental arch relationships were categorized with the Bauru-BCLP yardstick. Increments for each interval (from 6 to 9 years, 6 to 12 years, and 9 to 12 years) were analyzed by logistic and linear regression models. RESULTS: There were no significant differences in outcome measures between the centers at age 12 or at age 9. At age 6, center B showed significantly better results (p=.027), but this difference diminished as the yardstick score for this group increased over time (linear regression analysis), the difference with the reference category (center C, boys) for the intervals 6 to 12 and 9 to 12 years being 10.4% (p=.041) and 12.9% (p=.009), respectively. CONCLUSIONS: Despite different treatment protocols, dental arch relationships in the three centers were comparable in final scores at age 9 and 12 years. Delaying hard palate closure and employing infant orthopedics did not appear to be advantageous in the long run. Premaxillary osteotomy employed in center B appeared to be associated with less favorable development of the dental arch relationship between 9 and 12 years.
Resumo:
PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.
Resumo:
This study assessed the safety and efficacy of a novel implantable device therapy in resistant hypertension patients.
Resumo:
Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.
Resumo:
Our aim in this study was to compare intermolar widths after alignment of crowded mandibular dental arches in nonextraction adolescent patients between conventional and self-ligating brackets.
Resumo:
The current gold-standard for diagnosing heparin-induced thrombocytopenia is the detection of platelet-activating antibodies by means of functional assays which, since they are time consuming and not widely available, are not suited to guiding acute treatment decisions. The objective of our study was to assess the ability of more rapid immunoassays to predict the presence of functionally relevant anti-platelet factor 4/heparin-antibodies.