We evaluated a novel, sled-mounted needle guide for ultrasound-guided vessel cannulation. Fifty medical students were randomly assigned to use ultrasound with the sled (sled group, n = 23) or ultrasound without the sled (control group, n = 27) for vessel cannulation in a phantom. For each of 15 attempts we recorded cannulation time and designated a successful cannulation as 1 and a failure as 0. Our primary outcome was the mean overall success rate. The median (IQR [range]) number of successes in the sled group and control group were 15.0 (13.0-15.0 [11.0-15.0]) and 11.0 (9.0-13.0 [6.0-15.0]), respectively (p < 0.001). Cannulation time decreased from the first to the last attempt in the sled group from 7.0 s (6.0-10.0 [4.0-16]) s to 4.0 s (3.0-4.0 [1.0-6.0]) s and in the control group from 35.0 s (27.0-35.0 [11.0-35.0]) s to 7.0 s (5.0-10.0 [3.0-25.0]) s. The sled group demonstrated a shorter cannulation time at each attempt (p < 0.001). The novel sled improved the success rate and efficiency of ultrasound-guided phantom vessel cannulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right axillary artery (RAA) cannulation is increasingly used in cardiac surgery. Little is known about resulting flow patterns in the aorta. Therefore, flow was visualized and analyzed. A mock circulatory circuit was assembled based on a compliant transparent anatomical silicon aortic model. A RAA cannula was connected to a continuous flow rotary blood pump (RBP), pulsatile heart action was provided by a pneumatic ventricular assist device (PVAD). Peripheral vascular resistance, regional flow and vascular compliance were adjusted to obtain physiological flow and pressure waveforms. Colorants were injected automatically for flow visualization. Five flow distributions with a total flow of 4 l/min were tested (%PVAD:%RBP): 100:0, 75:25, 50:50, 25:75, 0:100. Colorant distribution was assessed using quantitative 2D image processing. Continuous flow from the RAA divided in a retrograde and an antegrade portion. Retro- to antegrade flow ratio increased with increasing RAA-flow. At full RBP support flow was stagnant in the ascending aorta. There were distinct flow patterns between the right- and left-sided supra-aortic branches. At full RBP support retrograde flow was demonstrated in the right carotid and right vertebral arteries. Further studies are needed to confirm and evaluate the described flow patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of positioning and geometry of ventricular cannulas for contemporary continuous flow Left Ventricular Assist Devices (LVADs) was evaluated in a non-beating isolated heart preparation with borescopic visualization. Preload and LVAD flow were varied to evaluate degrees of ventricular decompression up to the point of ventricular collapse. The performance of a flanged cannula was compared to a conventional bevel-tipped cannula: quantitatively by the maximal flow attainable, and qualitatively by visualization of fluid tracer particles within the ventricular chamber. Three forms of ventricular suck-down occurred: concentric collapse, gradual entrainment and instantaneous entrainment. In some circumstances, unstable oscillations of the ventricle were observed prior to complete collapse. Under conditions of low preload, the flanged cannula demonstrated less positional sensitivity, provided greater flow, and exhibited fewer areas of stagnation than the beveled cannula. These observations warrant further consideration of a flanged ventricular cannula to mitigate complications encountered with conventional cannulae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 77-year-old woman underwent aortic valve replacement and coronary bypass grafting in 2007 in the Emirates. Evolution was uneventful until December 2011. After repeated episodes of unspecific infections, a computed tomographic scan showed a large pseudoaneurysm of the distal ascending aorta. The site of aortic rupture was closed with a Gore-Tex patch and a Staphylococcus aureus infection treated appropriately. Two months later, a small cutaneous lesion on the cranial part of the sternotomy started bleeding. Computed tomographic scan demonstrated recurrence of a false aneurysm with erosion of the sternum and a large subcutaneous hematoma caused by the fistula. The patient was transferred to our institution. The challenges of this case included safe surgical approach (sternotomy, cannulation, perfusion, cerebral protection) as well as complete removal and extensive debridement of the infected material and reconstruction of the aortic arch. Using fully biological material, reconstruction of the ascending aorta and proximal arch was successfully performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Noninvasive intraocular pressure (IOP) measurement in mice is critically important for understanding the pathophysiology of glaucoma. Rebound tonometry is one of the methods that can be used for obtaining such measurements. We evaluated the ability of the rebound tonometer (RT) to determine IOP differences among various mouse strains and whether differences in corneal thickness may affect IOP measurements in these animals. MATERIALS AND METHODS: Five different commonly used mouse strains (BALB/C, CBA/CAHN, AKR/J, CBA/J, and 129P3/J) were used. IOP was measured in eyes from 12 nonsedated animals (6 male and 6 female) from each strain at 2 to 3 months of age using the RT. IOPs were measured in all animals, on 2 different days between 10 AM and 12 PM. Subsequently, a number of eyes from each strain were cannulated to provide a calibration curve specific for that strain. Tonometer readings for all strains were converted to apparent IOP values using the calibration data obtained from the calibration curve of the respective strain. For comparison purposes, IOP values were also obtained using the C57BL/6 calibration data previously reported. IOP for the 5 strains, male and female animals, and the different occasion of measurement were compared using repeat measures analysis of variance. The central corneal thickness (CCT) of another group of 8 male animals from each of the 5 strains was also measured using an optical low coherence reflectometry (OLCR) pachymeter modified for use with mice. CCT values were correlated to mean IOPs of male animals and to the slopes and intercept of individual strain calibration curves. RESULTS: Noninvasive IOP measurements confirm that the BALB/C strain has lower and the CBA/CAHN has higher relative IOPs than other mouse strains while the AKR/J, the CBA/J, and the 129P3/J strains have intermediate IOPs. There is a very good correlation of apparent IOP values obtained by RT with previously reported true IOPs obtained by cannulation. There was a small but statistically significant difference in IOP between male and female animals in 2 strains (129P3/J and AKR/J) with female mice having higher relative IOPs. No correlation between CCT and IOP was detected. CCT did not correlate with any of the constants describing the calibration curves in the various strains. CONCLUSIONS: Noninvasive IOP measurement in mice using the RT can be used to help elucidate IOP phenotype, after prior calibration of the tonometer. CCT has no effect on mouse IOP measurements using the RT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim of the study was to investigate the possible mechanisms leading to stunted growth and osteoporosis in experimental arthritis. Fourty-two female rats of 7-8 weeks of age were randomly assigned to three groups of 14 animals each: (a) controls; (b) adjuvant-inoculated (AA); and (c) adjuvant-inoculated rats receiving 10 mg cyclosporin A (CsA) orally for 30 days. Biological parameters studied were: hindpaw swelling; vertebral length progression expressed as Delta increments between days 1 and 30 as a parameter of skeletal growth, and estimation of total skeletal mineral content by dual energy X-ray absorptiometry (n=10 each group) on day 30. Endocrine parameters measured were pulsatile release of growth hormone (rGH) on day 30 following jugular cannulation and measurement of insulin-like growth factor (IGF-1) in pooled plasma from rGH profiles. Results can be summarized as follows: Untreated AA rats exhibited local signs of inflammation in comparison with controls (hindpaw diameter 8.1-8.9 mm vs. 5.3-5.6 mm in controls). Treatment with CsA normalized this parameter (4.9-5.6 mm). Vertebral growth was significantly retarded in AA rats in comparison with controls (214+/-32 vs. 473+/-33 microm; p<0.001). Administration of CsA normalized vertebral size increment with a clear tendency to overgrowth (523+/-43 microm, n.s.). There was also a marked reduction in total skeletal mineral content in diseased (AA) rats as compared to controls (5.8+/-0.1 vs. 7.5+/-0.1g [OH-apatite]; p<0.001), and a moderate but significant increment above controls in the group receiving CsA (8.0+/-0.1 vs. 7.5+/-0.1g [OH-appatite]; p<0.04). Integrated rGH profiles exhibited a significant fall in arthritic rats and were completely restored to normal under CsA treatment. A trend toward higher rGH values was observed in the latter group (2908+/-554 in AA vs. 8317+/-1492 ng/ml/240 min in controls; p<0.001, and 10940+/-222 ng/ml/240 min, n.s. in the CsA group). There was a good correlation between skeletal growth and rGH pulsatility (r=0.81; p<0.001). IGF-1 followed a similar pattern (630+/-44 in AA vs. 752+/-30 ng/ml in controls; p<0.04, and 769+/-59 ng/ml in the CsA group, n.s. vs. controls). Thus, a clear tendency to skeletal overgrowth following treatment was observed in agreement with the hormonal data. It can therefore be concluded that, in experimental arthritis, attenuated GH-spiking and reduced circulating IGF-1 appear to be causally related to growth retardation, probably mimicking signs and symptoms observed in juvenile arthritis. Therapy with CsA is followed by normalization of hormonal and biological parameters accompanied by a catch up phenomenon in skeletal growth which is also observed clinically in juvenile arthritis. Generalized osteopenia is a prominent feature seemingly connected with the growth abnormalities as they parallel each other during the evolution of the disease and respond equally to therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study is to evaluate the effects of crossclamping the ascending aorta in acute type A aortic dissection during the cooling phase for deep hypothermic arrest on early clinical outcome. METHODS: The records of 275 consecutive patients who underwent surgery for acute type A aortic dissection were reviewed. Ten patients have been excluded. Overall, 265 patients who underwent surgery under deep hypothermia and circulatory arrest in the "open technique" were divided retrospectively into two groups: those who underwent surgery with crossclamping of the ascending aorta during the cooling phase at the begin of the procedure (group 1, n = 191; 72.1 %) and those in whom the aorta was not clamped (group 2, n = 74; 27.9 %). RESULTS: Preoperative characteristics were similar in both groups. In group 1, femoral artery cannulation, composite graft repair, and aortic arch replacement were significantly more frequent. In-hospital mortality was 15.2 % in group 1 and 17.6 % in group 2 (P = not significant). Neurologic deficits were observed in 9.4% in group 1 and in 10.8% in group 2 (= not significant). There were no significant differences in clinical outcome between the two groups of patients. CONCLUSIONS: This study demonstrates that both options, aortic crossclamping or noclamping, may be used during the induction of deep hypothermia to repair acute type A aortic dissections with similar early clinical outcome. For the selection of the most appropriate technique, we recommend case by case evaluation, weighing the potential risks and benefits of aortic crossclamping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a case of massive embolization of atherosclerotic material during aortic cannulation and the surgical approach chosen to treat it, that is, retrograde cerebral perfusion and subtotal arch replacement in deep hypothermic circulatory arrest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.